TY - JOUR
T1 - Utility of second-generation single-energy metal artifact reduction in helical lung computed tomography for patients with pulmonary arteriovenous malformation after coil embolization
AU - Asano, Yudai
AU - Tada, Akihiro
AU - Shinya, Takayoshi
AU - Masaoka, Yoshihisa
AU - Iguchi, Toshihiro
AU - Sato, Shuhei
AU - Kanazawa, Susumu
N1 - Publisher Copyright:
© 2018, Japan Radiological Society.
Copyright:
Copyright 2018 Elsevier B.V., All rights reserved.
PY - 2018/4/1
Y1 - 2018/4/1
N2 - Purpose: The quality of images acquired using single-energy metal artifact reduction (SEMAR) on helical lung computed tomography (CT) in patients with pulmonary arteriovenous malformation (PAVM) after coil embolization was retrospectively evaluated. Materials and methods: CT images were reconstructed with and without SEMAR. Twenty-seven lesions [20 patients (2 males, 18 females), mean age 61.2 ± 11.0 years; number of embolization coils, 9.8 ± 5.0] on contrast-enhanced CT and 18 lesions of non-enhanced lung CT concurrently performed were evaluated. Regions of interest were positioned around the coils and mean standard deviation value was compared as noise index. Two radiologists visually evaluated metallic coil artifacts using a four-point scale: 4 = minimal; 3 = mild; 2 = strong; 1 = extensive. Results: Noise index was significantly improved with SEMAR versus without SEMAR (median [interquartile range]; 194.4 [161.6–211.9] Hounsfield units [HU] vs. 243.9 [220.4–286.0] HU; p < 0.001). Visual score was significantly improved with SEMAR versus without SEMAR (Reader 1, 3 [3] vs.1 [1]; Reader 2, 3 [3] vs.1 [1]; p < 0.001). Significant differences were similarly demonstrated on lung CT (p < 0.001). Conclusion: SEMAR provided clear chest CT images in patients who underwent PAVM coil embolization.
AB - Purpose: The quality of images acquired using single-energy metal artifact reduction (SEMAR) on helical lung computed tomography (CT) in patients with pulmonary arteriovenous malformation (PAVM) after coil embolization was retrospectively evaluated. Materials and methods: CT images were reconstructed with and without SEMAR. Twenty-seven lesions [20 patients (2 males, 18 females), mean age 61.2 ± 11.0 years; number of embolization coils, 9.8 ± 5.0] on contrast-enhanced CT and 18 lesions of non-enhanced lung CT concurrently performed were evaluated. Regions of interest were positioned around the coils and mean standard deviation value was compared as noise index. Two radiologists visually evaluated metallic coil artifacts using a four-point scale: 4 = minimal; 3 = mild; 2 = strong; 1 = extensive. Results: Noise index was significantly improved with SEMAR versus without SEMAR (median [interquartile range]; 194.4 [161.6–211.9] Hounsfield units [HU] vs. 243.9 [220.4–286.0] HU; p < 0.001). Visual score was significantly improved with SEMAR versus without SEMAR (Reader 1, 3 [3] vs.1 [1]; Reader 2, 3 [3] vs.1 [1]; p < 0.001). Significant differences were similarly demonstrated on lung CT (p < 0.001). Conclusion: SEMAR provided clear chest CT images in patients who underwent PAVM coil embolization.
KW - Artifact reduction
KW - CT
KW - Metal implants
KW - Pulmonary arteriovenous malformation
KW - Single-energy metal artifact reduction algorithm
UR - http://www.scopus.com/inward/record.url?scp=85041929595&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85041929595&partnerID=8YFLogxK
U2 - 10.1007/s11604-018-0723-6
DO - 10.1007/s11604-018-0723-6
M3 - Article
C2 - 29429141
AN - SCOPUS:85041929595
SN - 1867-1071
VL - 36
SP - 285
EP - 294
JO - Japanese Journal of Radiology
JF - Japanese Journal of Radiology
IS - 4
ER -