TY - JOUR
T1 - Determination of Fluorine and Chlorine by Pyrohydrolysis and Ion Chromatography
T2 - Comparison with Alkaline Fusion Digestion and Ion Chromatography
AU - Wang, Qiaoyun
AU - Makishima, Akio
AU - Nakamura, Eizo
PY - 2010/6/1
Y1 - 2010/6/1
N2 - A method to determine F and Cl in silicate materials by employing pyrohydrolysis and ion chromatography (IC) is described. Pyrohydrolysis involved mixing a pulverised sample (~ 40 mg) with V2O5 (~ 160 mg) and heating to 1100 °C under a wet oxygen flow in a quartz tube. Recovery yields of F and Cl were ~ 97% using a NaF + NaCl standard solution. Detection limits of the pyrohydrolysis-IC method for silicate samples were 0.36 and 0.69 μg g-1 for F and Cl, respectively. Fluorine and Cl concentrations were determined in the reference materials JB-2, JB-3 and JA-1 from the GSJ; BCR-2, BHVO-1, BHVO-2, AGV-1 and AGV-2 from the USGS; and NIST SRM 610, 612 and 614 glasses. Precisions (RSD) for determinations of F were 1-13% (except NIST SRM 614) and 2-19% for Cl, and were dependent on the concentration and blank correction. Most results obtained in this study were in good agreement with those of previous studies. In comparison, the Na2CO3 + ZnO fusion method at 900 °C showed that the yields of F and Cl by alkaline fusion systematically decreased with fusion duration time. The yields were 84% and 83% for JB-3, inferring that F and Cl were lost in this alkaline fusion.
AB - A method to determine F and Cl in silicate materials by employing pyrohydrolysis and ion chromatography (IC) is described. Pyrohydrolysis involved mixing a pulverised sample (~ 40 mg) with V2O5 (~ 160 mg) and heating to 1100 °C under a wet oxygen flow in a quartz tube. Recovery yields of F and Cl were ~ 97% using a NaF + NaCl standard solution. Detection limits of the pyrohydrolysis-IC method for silicate samples were 0.36 and 0.69 μg g-1 for F and Cl, respectively. Fluorine and Cl concentrations were determined in the reference materials JB-2, JB-3 and JA-1 from the GSJ; BCR-2, BHVO-1, BHVO-2, AGV-1 and AGV-2 from the USGS; and NIST SRM 610, 612 and 614 glasses. Precisions (RSD) for determinations of F were 1-13% (except NIST SRM 614) and 2-19% for Cl, and were dependent on the concentration and blank correction. Most results obtained in this study were in good agreement with those of previous studies. In comparison, the Na2CO3 + ZnO fusion method at 900 °C showed that the yields of F and Cl by alkaline fusion systematically decreased with fusion duration time. The yields were 84% and 83% for JB-3, inferring that F and Cl were lost in this alkaline fusion.
KW - Alkaline fusion
KW - Chlorine
KW - Fluorine
KW - Ion chromatography
KW - Pyrohydrolysis
KW - Silicate reference materials
UR - http://www.scopus.com/inward/record.url?scp=77956247643&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=77956247643&partnerID=8YFLogxK
U2 - 10.1111/j.1751-908X.2010.00043.x
DO - 10.1111/j.1751-908X.2010.00043.x
M3 - Article
AN - SCOPUS:77956247643
SN - 0150-5505
VL - 34
SP - 175
EP - 183
JO - Geostandards and Geoanalytical Research
JF - Geostandards and Geoanalytical Research
IS - 2
ER -