抄録
The Belle-II VerteX Detector (VXD) has been designed to improve the performances with respect to Belle and to cope with an unprecedented luminosity of 8×1035cm-2s-1 achievable by the SuperKEKB. Special care is needed to monitor both the radiation dose accumulated throughout the life of the experiment and the instantaneous radiation rate, in order to be able to promptly react to sudden spikes for the purpose of protecting the detectors. A radiation monitoring and beam abort system based on single-crystal diamond sensors is now under an active development for the VXD. The sensors will be placed in several key positions in the vicinity of the interaction region. The severe space limitations require a challenging remote readout of the sensors.
本文言語 | English |
---|---|
ページ(範囲) | 480-482 |
ページ数 | 3 |
ジャーナル | Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment |
巻 | 824 |
DOI | |
出版ステータス | Published - 7月 11 2016 |
ASJC Scopus subject areas
- 核物理学および高エネルギー物理学
- 器械工学