Way to increase mechanical strength during distraction osteogenesis of the mandibular symphysis

Technical note

Tomonao Aikawa, Kaoru Ohnishi, Hidetake Ohnishi, Seiji Iida

Research output: Contribution to journalArticle

1 Citation (Scopus)
Original languageEnglish
Pages (from-to)670-671
Number of pages2
JournalBritish Journal of Oral and Maxillofacial Surgery
Volume49
Issue number8
DOIs
Publication statusPublished - Dec 2011

Fingerprint

Dental Stress Analysis
Orthognathic Surgical Procedures
Distraction Osteogenesis
External Fixators
Chin
Mechanical Stress
Malocclusion
Mandible

Keywords

  • Adjustable bone fixation plate system
  • Hybrid distractor
  • Mandibular symphyseal distraction osteogenesis
  • Mechanical weakness

ASJC Scopus subject areas

  • Oral Surgery
  • Otorhinolaryngology
  • Surgery

Cite this

Way to increase mechanical strength during distraction osteogenesis of the mandibular symphysis : Technical note. / Aikawa, Tomonao; Ohnishi, Kaoru; Ohnishi, Hidetake; Iida, Seiji.

In: British Journal of Oral and Maxillofacial Surgery, Vol. 49, No. 8, 12.2011, p. 670-671.

Research output: Contribution to journalArticle

@article{e7e78ae789714440bc0729d6087992e5,
title = "Way to increase mechanical strength during distraction osteogenesis of the mandibular symphysis: Technical note",
keywords = "Adjustable bone fixation plate system, Hybrid distractor, Mandibular symphyseal distraction osteogenesis, Mechanical weakness",
author = "Tomonao Aikawa and Kaoru Ohnishi and Hidetake Ohnishi and Seiji Iida",
year = "2011",
month = "12",
doi = "10.1016/j.bjoms.2010.09.004",
language = "English",
volume = "49",
pages = "670--671",
journal = "British Journal of Oral and Maxillofacial Surgery",
issn = "0266-4356",
publisher = "Churchill Livingstone",
number = "8",

}

TY - JOUR

T1 - Way to increase mechanical strength during distraction osteogenesis of the mandibular symphysis

T2 - Technical note

AU - Aikawa, Tomonao

AU - Ohnishi, Kaoru

AU - Ohnishi, Hidetake

AU - Iida, Seiji

PY - 2011/12

Y1 - 2011/12

KW - Adjustable bone fixation plate system

KW - Hybrid distractor

KW - Mandibular symphyseal distraction osteogenesis

KW - Mechanical weakness

UR - http://www.scopus.com/inward/record.url?scp=82355170014&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=82355170014&partnerID=8YFLogxK

U2 - 10.1016/j.bjoms.2010.09.004

DO - 10.1016/j.bjoms.2010.09.004

M3 - Article

VL - 49

SP - 670

EP - 671

JO - British Journal of Oral and Maxillofacial Surgery

JF - British Journal of Oral and Maxillofacial Surgery

SN - 0266-4356

IS - 8

ER -