Transport and emittance study for 18 GHz superconducting-ECR ion source at RCNP

T. Yorita, K. Hatanaka, M. Fukuda, Hiroshi Ueda, M. Kibayashi, S. Morinobu, A. Tamii

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

As the upgrade program of the azimuthally varying field (AVF) cyclotron is at the cyclotron facility of the RCNP, Osaka University for the improvement of the quality, stability, and intensity of accelerated beams, an 18 GHz superconducting (SC) ECR ion source has been installed to increase beam currents and to extend the variety of ions, especially for highly charged heavy ions which can be accelerated by RCNP AVF cyclotron. The production development of several ions such as B, O, N, Ne, Ar, Ni, Kr, and Xe has been performed by Yorita Rev. Sci. Instrum. 79, 02A311(2008); 81, 02A332 (2010). Further studies for the beam transport have been done in order to improve the beam current more for injection of cyclotron. The effect of field leakage of AVF main coil is not negligible and additional steering magnet has been installed and then beam transmission has been improved. The emittance monitor has also been developed for the purpose of investigating correlation between emittance of beam from ECR ion sources and injection efficiency. The monitor consists with BPM82 with rotating wire for fast measurement for efficient study.

Original languageEnglish
Article number02A335
JournalReview of Scientific Instruments
Volume83
Issue number2
DOIs
Publication statusPublished - 2012
Externally publishedYes

Fingerprint

Cyclotrons
Ion sources
emittance
ion sources
cyclotrons
beam currents
monitors
ion injection
Ions
Heavy ions
Magnets
heavy ions
ions
leakage
magnets
coils
wire
Wire
injection

ASJC Scopus subject areas

  • Instrumentation

Cite this

Yorita, T., Hatanaka, K., Fukuda, M., Ueda, H., Kibayashi, M., Morinobu, S., & Tamii, A. (2012). Transport and emittance study for 18 GHz superconducting-ECR ion source at RCNP. Review of Scientific Instruments, 83(2), [02A335]. https://doi.org/10.1063/1.3671748

Transport and emittance study for 18 GHz superconducting-ECR ion source at RCNP. / Yorita, T.; Hatanaka, K.; Fukuda, M.; Ueda, Hiroshi; Kibayashi, M.; Morinobu, S.; Tamii, A.

In: Review of Scientific Instruments, Vol. 83, No. 2, 02A335, 2012.

Research output: Contribution to journalArticle

Yorita, T, Hatanaka, K, Fukuda, M, Ueda, H, Kibayashi, M, Morinobu, S & Tamii, A 2012, 'Transport and emittance study for 18 GHz superconducting-ECR ion source at RCNP', Review of Scientific Instruments, vol. 83, no. 2, 02A335. https://doi.org/10.1063/1.3671748
Yorita, T. ; Hatanaka, K. ; Fukuda, M. ; Ueda, Hiroshi ; Kibayashi, M. ; Morinobu, S. ; Tamii, A. / Transport and emittance study for 18 GHz superconducting-ECR ion source at RCNP. In: Review of Scientific Instruments. 2012 ; Vol. 83, No. 2.
@article{658fd058035c46bf835af5190c7db70e,
title = "Transport and emittance study for 18 GHz superconducting-ECR ion source at RCNP",
abstract = "As the upgrade program of the azimuthally varying field (AVF) cyclotron is at the cyclotron facility of the RCNP, Osaka University for the improvement of the quality, stability, and intensity of accelerated beams, an 18 GHz superconducting (SC) ECR ion source has been installed to increase beam currents and to extend the variety of ions, especially for highly charged heavy ions which can be accelerated by RCNP AVF cyclotron. The production development of several ions such as B, O, N, Ne, Ar, Ni, Kr, and Xe has been performed by Yorita Rev. Sci. Instrum. 79, 02A311(2008); 81, 02A332 (2010). Further studies for the beam transport have been done in order to improve the beam current more for injection of cyclotron. The effect of field leakage of AVF main coil is not negligible and additional steering magnet has been installed and then beam transmission has been improved. The emittance monitor has also been developed for the purpose of investigating correlation between emittance of beam from ECR ion sources and injection efficiency. The monitor consists with BPM82 with rotating wire for fast measurement for efficient study.",
author = "T. Yorita and K. Hatanaka and M. Fukuda and Hiroshi Ueda and M. Kibayashi and S. Morinobu and A. Tamii",
year = "2012",
doi = "10.1063/1.3671748",
language = "English",
volume = "83",
journal = "Review of Scientific Instruments",
issn = "0034-6748",
publisher = "American Institute of Physics Publising LLC",
number = "2",

}

TY - JOUR

T1 - Transport and emittance study for 18 GHz superconducting-ECR ion source at RCNP

AU - Yorita, T.

AU - Hatanaka, K.

AU - Fukuda, M.

AU - Ueda, Hiroshi

AU - Kibayashi, M.

AU - Morinobu, S.

AU - Tamii, A.

PY - 2012

Y1 - 2012

N2 - As the upgrade program of the azimuthally varying field (AVF) cyclotron is at the cyclotron facility of the RCNP, Osaka University for the improvement of the quality, stability, and intensity of accelerated beams, an 18 GHz superconducting (SC) ECR ion source has been installed to increase beam currents and to extend the variety of ions, especially for highly charged heavy ions which can be accelerated by RCNP AVF cyclotron. The production development of several ions such as B, O, N, Ne, Ar, Ni, Kr, and Xe has been performed by Yorita Rev. Sci. Instrum. 79, 02A311(2008); 81, 02A332 (2010). Further studies for the beam transport have been done in order to improve the beam current more for injection of cyclotron. The effect of field leakage of AVF main coil is not negligible and additional steering magnet has been installed and then beam transmission has been improved. The emittance monitor has also been developed for the purpose of investigating correlation between emittance of beam from ECR ion sources and injection efficiency. The monitor consists with BPM82 with rotating wire for fast measurement for efficient study.

AB - As the upgrade program of the azimuthally varying field (AVF) cyclotron is at the cyclotron facility of the RCNP, Osaka University for the improvement of the quality, stability, and intensity of accelerated beams, an 18 GHz superconducting (SC) ECR ion source has been installed to increase beam currents and to extend the variety of ions, especially for highly charged heavy ions which can be accelerated by RCNP AVF cyclotron. The production development of several ions such as B, O, N, Ne, Ar, Ni, Kr, and Xe has been performed by Yorita Rev. Sci. Instrum. 79, 02A311(2008); 81, 02A332 (2010). Further studies for the beam transport have been done in order to improve the beam current more for injection of cyclotron. The effect of field leakage of AVF main coil is not negligible and additional steering magnet has been installed and then beam transmission has been improved. The emittance monitor has also been developed for the purpose of investigating correlation between emittance of beam from ECR ion sources and injection efficiency. The monitor consists with BPM82 with rotating wire for fast measurement for efficient study.

UR - http://www.scopus.com/inward/record.url?scp=84857839121&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84857839121&partnerID=8YFLogxK

U2 - 10.1063/1.3671748

DO - 10.1063/1.3671748

M3 - Article

VL - 83

JO - Review of Scientific Instruments

JF - Review of Scientific Instruments

SN - 0034-6748

IS - 2

M1 - 02A335