The large Debye-Scherrer camera installed at SPring-8 BL02B2 for charge density studies

E. Nishibori, M. Takata, K. Kato, M. Sakata, Y. Kubota, S. Aoyagi, Y. Kuroiwa, M. Yamakata, Naoshi Ikeda

Research output: Contribution to journalArticle

63 Citations (Scopus)

Abstract

The design and performance of a large Debye-Scherrer Camera with Imaging Plate (IP) as detectors, which was very recently installed at SPring-8, BL02B2, is reported. By taking advantage of high beam quality of SPring-8, the camera enables a rapid collection of a high counting statistics and high angular resolution powder pattern, which should be suitable for charge density studies by powder specimens. The camera also provides easy access to investigation of structural changes at varied temperatures between 15-1000 K. The camera provides an advanced powder diffraction system utilizing third generation SR, i.e. rapid and accurate.

Original languageEnglish
Pages (from-to)2095-2098
Number of pages4
JournalJournal of Physics and Chemistry of Solids
Volume62
Issue number12
DOIs
Publication statusPublished - Dec 2001
Externally publishedYes

Fingerprint

Charge density
Cameras
cameras
Powders
Beam quality
angular resolution
counting
Statistics
statistics
Detectors
Imaging techniques
high resolution
detectors
diffraction
Temperature
temperature

ASJC Scopus subject areas

  • Electronic, Optical and Magnetic Materials
  • Condensed Matter Physics

Cite this

The large Debye-Scherrer camera installed at SPring-8 BL02B2 for charge density studies. / Nishibori, E.; Takata, M.; Kato, K.; Sakata, M.; Kubota, Y.; Aoyagi, S.; Kuroiwa, Y.; Yamakata, M.; Ikeda, Naoshi.

In: Journal of Physics and Chemistry of Solids, Vol. 62, No. 12, 12.2001, p. 2095-2098.

Research output: Contribution to journalArticle

Nishibori, E, Takata, M, Kato, K, Sakata, M, Kubota, Y, Aoyagi, S, Kuroiwa, Y, Yamakata, M & Ikeda, N 2001, 'The large Debye-Scherrer camera installed at SPring-8 BL02B2 for charge density studies', Journal of Physics and Chemistry of Solids, vol. 62, no. 12, pp. 2095-2098. https://doi.org/10.1016/S0022-3697(01)00164-0
Nishibori, E. ; Takata, M. ; Kato, K. ; Sakata, M. ; Kubota, Y. ; Aoyagi, S. ; Kuroiwa, Y. ; Yamakata, M. ; Ikeda, Naoshi. / The large Debye-Scherrer camera installed at SPring-8 BL02B2 for charge density studies. In: Journal of Physics and Chemistry of Solids. 2001 ; Vol. 62, No. 12. pp. 2095-2098.
@article{8ae2f6eb32064b37a1450d2d833a2196,
title = "The large Debye-Scherrer camera installed at SPring-8 BL02B2 for charge density studies",
abstract = "The design and performance of a large Debye-Scherrer Camera with Imaging Plate (IP) as detectors, which was very recently installed at SPring-8, BL02B2, is reported. By taking advantage of high beam quality of SPring-8, the camera enables a rapid collection of a high counting statistics and high angular resolution powder pattern, which should be suitable for charge density studies by powder specimens. The camera also provides easy access to investigation of structural changes at varied temperatures between 15-1000 K. The camera provides an advanced powder diffraction system utilizing third generation SR, i.e. rapid and accurate.",
author = "E. Nishibori and M. Takata and K. Kato and M. Sakata and Y. Kubota and S. Aoyagi and Y. Kuroiwa and M. Yamakata and Naoshi Ikeda",
year = "2001",
month = "12",
doi = "10.1016/S0022-3697(01)00164-0",
language = "English",
volume = "62",
pages = "2095--2098",
journal = "Journal of Physics and Chemistry of Solids",
issn = "0022-3697",
publisher = "Elsevier Limited",
number = "12",

}

TY - JOUR

T1 - The large Debye-Scherrer camera installed at SPring-8 BL02B2 for charge density studies

AU - Nishibori, E.

AU - Takata, M.

AU - Kato, K.

AU - Sakata, M.

AU - Kubota, Y.

AU - Aoyagi, S.

AU - Kuroiwa, Y.

AU - Yamakata, M.

AU - Ikeda, Naoshi

PY - 2001/12

Y1 - 2001/12

N2 - The design and performance of a large Debye-Scherrer Camera with Imaging Plate (IP) as detectors, which was very recently installed at SPring-8, BL02B2, is reported. By taking advantage of high beam quality of SPring-8, the camera enables a rapid collection of a high counting statistics and high angular resolution powder pattern, which should be suitable for charge density studies by powder specimens. The camera also provides easy access to investigation of structural changes at varied temperatures between 15-1000 K. The camera provides an advanced powder diffraction system utilizing third generation SR, i.e. rapid and accurate.

AB - The design and performance of a large Debye-Scherrer Camera with Imaging Plate (IP) as detectors, which was very recently installed at SPring-8, BL02B2, is reported. By taking advantage of high beam quality of SPring-8, the camera enables a rapid collection of a high counting statistics and high angular resolution powder pattern, which should be suitable for charge density studies by powder specimens. The camera also provides easy access to investigation of structural changes at varied temperatures between 15-1000 K. The camera provides an advanced powder diffraction system utilizing third generation SR, i.e. rapid and accurate.

UR - http://www.scopus.com/inward/record.url?scp=0035743695&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0035743695&partnerID=8YFLogxK

U2 - 10.1016/S0022-3697(01)00164-0

DO - 10.1016/S0022-3697(01)00164-0

M3 - Article

VL - 62

SP - 2095

EP - 2098

JO - Journal of Physics and Chemistry of Solids

JF - Journal of Physics and Chemistry of Solids

SN - 0022-3697

IS - 12

ER -