Surface plasmon resonance biosensor with high anti-fouling ability for the detection of cardiac marker troponin T

Jen Tsai Liu, Ching Jung Chen, Toshiyuki Ikoma, Tomohiko Yoshioka, Jeffrey S. Cross, Shwu Jen Chang, Jang Zern Tsai, Junzo Tanaka

Research output: Contribution to journalArticle

35 Citations (Scopus)

Abstract

Designing a surface recognition layer with high anti-fouling ability, high affinity, and high specificity is an important issue to produce high sensitivity biosensing transducers. In this study, a self-assembled monolayer (SAM) consisting of a homogeneous mixture of oligo(ethylene glycol) (OEG)-terminated alkanethiolate and mercaptohexadecanoic acid (MHDA) on Au was employed for immobilizing troponin T antibody and applied in detecting cardiac troponin T by using surface plasmon resonance (SPR). The mixed SAM showed no phase segregation and exhibited human serum albumin resistance, particularly with an antibody-immobilized surface. X-ray photoemission spectra revealed that the chemical composition ratio of OEG to the mixed SAM was 69% and the OEG packing density was 82%. The specific binding of troponin T on the designed surface indicated a good linear correlation (R=0.991, P-1 with the limit of detection of 100ngmL -1 using a SPR measuring instrument. It is concluded that the mixed SAM functions as designed since it has high detection capability, high accuracy and reproducibility, as well as shows strong potential to be applied in rapid clinical diagnosis for label-free detection within 2min.

Original languageEnglish
Pages (from-to)80-86
Number of pages7
JournalAnalytica Chimica Acta
Volume703
Issue number1
DOIs
Publication statusPublished - Oct 3 2011
Externally publishedYes

Fingerprint

Troponin T
Surface Plasmon Resonance
antifouling
Surface plasmon resonance
Biosensing Techniques
Self assembled monolayers
Fouling
Biosensors
Immobilized Antibodies
Ethylene Glycol
antibody
Transducers
Serum Albumin
Limit of Detection
Photoemission
X-Rays
Labels
transducer
Acids
Antibodies

Keywords

  • Anti-fouling ability
  • Myocardial infarction
  • Oligoethylene glycol
  • Self-assembled monolayer
  • Surface plasmon resonance
  • Troponin T

ASJC Scopus subject areas

  • Biochemistry
  • Analytical Chemistry
  • Spectroscopy
  • Environmental Chemistry

Cite this

Surface plasmon resonance biosensor with high anti-fouling ability for the detection of cardiac marker troponin T. / Liu, Jen Tsai; Chen, Ching Jung; Ikoma, Toshiyuki; Yoshioka, Tomohiko; Cross, Jeffrey S.; Chang, Shwu Jen; Tsai, Jang Zern; Tanaka, Junzo.

In: Analytica Chimica Acta, Vol. 703, No. 1, 03.10.2011, p. 80-86.

Research output: Contribution to journalArticle

Liu, Jen Tsai ; Chen, Ching Jung ; Ikoma, Toshiyuki ; Yoshioka, Tomohiko ; Cross, Jeffrey S. ; Chang, Shwu Jen ; Tsai, Jang Zern ; Tanaka, Junzo. / Surface plasmon resonance biosensor with high anti-fouling ability for the detection of cardiac marker troponin T. In: Analytica Chimica Acta. 2011 ; Vol. 703, No. 1. pp. 80-86.
@article{20b51bb8e233482bb97d76b5b9818264,
title = "Surface plasmon resonance biosensor with high anti-fouling ability for the detection of cardiac marker troponin T",
abstract = "Designing a surface recognition layer with high anti-fouling ability, high affinity, and high specificity is an important issue to produce high sensitivity biosensing transducers. In this study, a self-assembled monolayer (SAM) consisting of a homogeneous mixture of oligo(ethylene glycol) (OEG)-terminated alkanethiolate and mercaptohexadecanoic acid (MHDA) on Au was employed for immobilizing troponin T antibody and applied in detecting cardiac troponin T by using surface plasmon resonance (SPR). The mixed SAM showed no phase segregation and exhibited human serum albumin resistance, particularly with an antibody-immobilized surface. X-ray photoemission spectra revealed that the chemical composition ratio of OEG to the mixed SAM was 69{\%} and the OEG packing density was 82{\%}. The specific binding of troponin T on the designed surface indicated a good linear correlation (R=0.991, P-1 with the limit of detection of 100ngmL -1 using a SPR measuring instrument. It is concluded that the mixed SAM functions as designed since it has high detection capability, high accuracy and reproducibility, as well as shows strong potential to be applied in rapid clinical diagnosis for label-free detection within 2min.",
keywords = "Anti-fouling ability, Myocardial infarction, Oligoethylene glycol, Self-assembled monolayer, Surface plasmon resonance, Troponin T",
author = "Liu, {Jen Tsai} and Chen, {Ching Jung} and Toshiyuki Ikoma and Tomohiko Yoshioka and Cross, {Jeffrey S.} and Chang, {Shwu Jen} and Tsai, {Jang Zern} and Junzo Tanaka",
year = "2011",
month = "10",
day = "3",
doi = "10.1016/j.aca.2011.07.019",
language = "English",
volume = "703",
pages = "80--86",
journal = "Analytica Chimica Acta",
issn = "0003-2670",
publisher = "Elsevier",
number = "1",

}

TY - JOUR

T1 - Surface plasmon resonance biosensor with high anti-fouling ability for the detection of cardiac marker troponin T

AU - Liu, Jen Tsai

AU - Chen, Ching Jung

AU - Ikoma, Toshiyuki

AU - Yoshioka, Tomohiko

AU - Cross, Jeffrey S.

AU - Chang, Shwu Jen

AU - Tsai, Jang Zern

AU - Tanaka, Junzo

PY - 2011/10/3

Y1 - 2011/10/3

N2 - Designing a surface recognition layer with high anti-fouling ability, high affinity, and high specificity is an important issue to produce high sensitivity biosensing transducers. In this study, a self-assembled monolayer (SAM) consisting of a homogeneous mixture of oligo(ethylene glycol) (OEG)-terminated alkanethiolate and mercaptohexadecanoic acid (MHDA) on Au was employed for immobilizing troponin T antibody and applied in detecting cardiac troponin T by using surface plasmon resonance (SPR). The mixed SAM showed no phase segregation and exhibited human serum albumin resistance, particularly with an antibody-immobilized surface. X-ray photoemission spectra revealed that the chemical composition ratio of OEG to the mixed SAM was 69% and the OEG packing density was 82%. The specific binding of troponin T on the designed surface indicated a good linear correlation (R=0.991, P-1 with the limit of detection of 100ngmL -1 using a SPR measuring instrument. It is concluded that the mixed SAM functions as designed since it has high detection capability, high accuracy and reproducibility, as well as shows strong potential to be applied in rapid clinical diagnosis for label-free detection within 2min.

AB - Designing a surface recognition layer with high anti-fouling ability, high affinity, and high specificity is an important issue to produce high sensitivity biosensing transducers. In this study, a self-assembled monolayer (SAM) consisting of a homogeneous mixture of oligo(ethylene glycol) (OEG)-terminated alkanethiolate and mercaptohexadecanoic acid (MHDA) on Au was employed for immobilizing troponin T antibody and applied in detecting cardiac troponin T by using surface plasmon resonance (SPR). The mixed SAM showed no phase segregation and exhibited human serum albumin resistance, particularly with an antibody-immobilized surface. X-ray photoemission spectra revealed that the chemical composition ratio of OEG to the mixed SAM was 69% and the OEG packing density was 82%. The specific binding of troponin T on the designed surface indicated a good linear correlation (R=0.991, P-1 with the limit of detection of 100ngmL -1 using a SPR measuring instrument. It is concluded that the mixed SAM functions as designed since it has high detection capability, high accuracy and reproducibility, as well as shows strong potential to be applied in rapid clinical diagnosis for label-free detection within 2min.

KW - Anti-fouling ability

KW - Myocardial infarction

KW - Oligoethylene glycol

KW - Self-assembled monolayer

KW - Surface plasmon resonance

KW - Troponin T

UR - http://www.scopus.com/inward/record.url?scp=80051668326&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=80051668326&partnerID=8YFLogxK

U2 - 10.1016/j.aca.2011.07.019

DO - 10.1016/j.aca.2011.07.019

M3 - Article

C2 - 21843678

AN - SCOPUS:80051668326

VL - 703

SP - 80

EP - 86

JO - Analytica Chimica Acta

JF - Analytica Chimica Acta

SN - 0003-2670

IS - 1

ER -