TY - JOUR
T1 - Screening of sperm velocity by fluid mechanical characteristics of a cyclo-olefin polymer microfluidic sperm-sorting device
AU - Matsuura, Koji
AU - Takenami, Mami
AU - Kuroda, Yuka
AU - Hyakutake, Toru
AU - Yanase, Shinichiro
AU - Naruse, Keiji
N1 - Funding Information:
This study was partly supported by a grant-in-aid for Scientific Research for Young Scientists (B) (no. 20700380 to KM), by Priority Areas (no. 17076006 to KN), and by Special Coordination Funds for Promoting Sciences and Technology from the Ministry of Education, Culture, Sports, Science and Technology, Japan (to KM). KM thanks Gentaro Iribe (Okayama University, Japan) for helping with fluorescence microscopy and confocal scanning.
PY - 2012/1
Y1 - 2012/1
N2 - The microfluidic sperm-sorting (MFSS) device is a promising advancement for assisted reproductive technology. Previously, poly(dimethylsiloxiane) and quartz MFSS devices were developed and used for intracytoplasmic sperm injection. However, these disposable devices were not clinically suitable for assisted reproduction, so a cyclo-olefin polymer MFSS (COP-MFSS) device was developed. By micromachining, two microfluidic channels with different heights and widths (chip A: 0.3 x 0.5 mm; chip B: 0.1 x 0.6 mm) were prepared. Sorted sperm concentrations were similar in both microfluidic channels. Linear-velocity distribution using the microfluidic channel of chip B was higher than that of chip A. Using confocal fluorescence microscopy, it was found that the highest number of motile spermatozoa swam across the laminar flow at the bottom of the microfluidic channel. The time required to swim across the laminar flow was longer at the bottom and top of the microfluidic channels than in the middle because of the low fluid velocity. These results experimentally demonstrated that the width of microfluidic channels should be increased in the region of laminar flow from the semen inlet to the outlet for unsorted spermatozoa to selectively recover spermatozoa with high linear velocity. Microfluidic sperm sorting (MFSS) is a promising advance for assisted reproductive technology. Previously, poly(dimethylsiloxiane) and quartz MFSS devices were developed and used for intracytoplasmic sperm injection; however, these devices are neither disposable nor clinically suitable for assisted reproduction, so we developed a cyclo-olefin polymer (COP)-MFSS device. By micromachining, we prepared two microfluidic channels with different heights and widths (chip A: 0.3 x 0.5 mm; chip B: 0.1 x 0.6 mm), and subsequently used these channels to investigate the sperm linear velocity distribution and the sorted motile sperm concentration. The sorted sperm concentrations were similar in both microfluidic channels. The linear velocity distribution using the microfluidic channel of chip B was higher than that of chip A. To investigate the activity of sorted motile spermatozoa at different heights of the microfluidic channel (top, middle and bottom), we performed confocal fluorescence microscopy and found that the highest number of motile spermatozoa swam across the laminar flow at the bottom of the microfluidic channel. The time required to swim across the laminar flow was longer at the bottom and top of the microfluidic channels than at the middle of the channels because of the low fluid velocity. We experimentally demonstrated that the width, and not the height, of microfluidic channels should be increased in the region of laminar flow from the semen inlet to the outlet for unsorted spermatozoa to selectively recover spermatozoa with high linear velocity.
AB - The microfluidic sperm-sorting (MFSS) device is a promising advancement for assisted reproductive technology. Previously, poly(dimethylsiloxiane) and quartz MFSS devices were developed and used for intracytoplasmic sperm injection. However, these disposable devices were not clinically suitable for assisted reproduction, so a cyclo-olefin polymer MFSS (COP-MFSS) device was developed. By micromachining, two microfluidic channels with different heights and widths (chip A: 0.3 x 0.5 mm; chip B: 0.1 x 0.6 mm) were prepared. Sorted sperm concentrations were similar in both microfluidic channels. Linear-velocity distribution using the microfluidic channel of chip B was higher than that of chip A. Using confocal fluorescence microscopy, it was found that the highest number of motile spermatozoa swam across the laminar flow at the bottom of the microfluidic channel. The time required to swim across the laminar flow was longer at the bottom and top of the microfluidic channels than in the middle because of the low fluid velocity. These results experimentally demonstrated that the width of microfluidic channels should be increased in the region of laminar flow from the semen inlet to the outlet for unsorted spermatozoa to selectively recover spermatozoa with high linear velocity. Microfluidic sperm sorting (MFSS) is a promising advance for assisted reproductive technology. Previously, poly(dimethylsiloxiane) and quartz MFSS devices were developed and used for intracytoplasmic sperm injection; however, these devices are neither disposable nor clinically suitable for assisted reproduction, so we developed a cyclo-olefin polymer (COP)-MFSS device. By micromachining, we prepared two microfluidic channels with different heights and widths (chip A: 0.3 x 0.5 mm; chip B: 0.1 x 0.6 mm), and subsequently used these channels to investigate the sperm linear velocity distribution and the sorted motile sperm concentration. The sorted sperm concentrations were similar in both microfluidic channels. The linear velocity distribution using the microfluidic channel of chip B was higher than that of chip A. To investigate the activity of sorted motile spermatozoa at different heights of the microfluidic channel (top, middle and bottom), we performed confocal fluorescence microscopy and found that the highest number of motile spermatozoa swam across the laminar flow at the bottom of the microfluidic channel. The time required to swim across the laminar flow was longer at the bottom and top of the microfluidic channels than at the middle of the channels because of the low fluid velocity. We experimentally demonstrated that the width, and not the height, of microfluidic channels should be increased in the region of laminar flow from the semen inlet to the outlet for unsorted spermatozoa to selectively recover spermatozoa with high linear velocity.
KW - laminar flow
KW - linear velocity
KW - microfluidic sperm sorting
KW - motility
UR - http://www.scopus.com/inward/record.url?scp=84855346655&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84855346655&partnerID=8YFLogxK
U2 - 10.1016/j.rbmo.2011.09.005
DO - 10.1016/j.rbmo.2011.09.005
M3 - Article
C2 - 22116072
AN - SCOPUS:84855346655
SN - 1472-6483
VL - 24
SP - 109
EP - 115
JO - Reproductive BioMedicine Online
JF - Reproductive BioMedicine Online
IS - 1
ER -