MODELING OF BIOMECHANICAL IMPEDANCE.

Hisao Oka, Tatsuma Yamamoto

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

A new model of biomechanical impedance is proposed which has only four independent parameters which express impedance characteristics under relatively low static pressure. This model is embodied in the form of both a mathematical expression and a mechanical circuit. It can be used to clarify the mechanical structure of biomaterials.

Original languageEnglish
Title of host publicationJapanese Journal of Medical Electronics and Biological Engineering
PublisherJapan Soc of Medical Electronics & Biological Engineering
Pages858-859
Number of pages2
Volume22
Publication statusPublished - Apr 1984

Fingerprint

Biomaterials
Networks (circuits)

ASJC Scopus subject areas

  • Electrical and Electronic Engineering

Cite this

Oka, H., & Yamamoto, T. (1984). MODELING OF BIOMECHANICAL IMPEDANCE. In Japanese Journal of Medical Electronics and Biological Engineering (Vol. 22, pp. 858-859). Japan Soc of Medical Electronics & Biological Engineering.

MODELING OF BIOMECHANICAL IMPEDANCE. / Oka, Hisao; Yamamoto, Tatsuma.

Japanese Journal of Medical Electronics and Biological Engineering. Vol. 22 Japan Soc of Medical Electronics & Biological Engineering, 1984. p. 858-859.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Oka, H & Yamamoto, T 1984, MODELING OF BIOMECHANICAL IMPEDANCE. in Japanese Journal of Medical Electronics and Biological Engineering. vol. 22, Japan Soc of Medical Electronics & Biological Engineering, pp. 858-859.
Oka H, Yamamoto T. MODELING OF BIOMECHANICAL IMPEDANCE. In Japanese Journal of Medical Electronics and Biological Engineering. Vol. 22. Japan Soc of Medical Electronics & Biological Engineering. 1984. p. 858-859
Oka, Hisao ; Yamamoto, Tatsuma. / MODELING OF BIOMECHANICAL IMPEDANCE. Japanese Journal of Medical Electronics and Biological Engineering. Vol. 22 Japan Soc of Medical Electronics & Biological Engineering, 1984. pp. 858-859
@inproceedings{6ced726b6f964058b3b2675094a2fd4c,
title = "MODELING OF BIOMECHANICAL IMPEDANCE.",
abstract = "A new model of biomechanical impedance is proposed which has only four independent parameters which express impedance characteristics under relatively low static pressure. This model is embodied in the form of both a mathematical expression and a mechanical circuit. It can be used to clarify the mechanical structure of biomaterials.",
author = "Hisao Oka and Tatsuma Yamamoto",
year = "1984",
month = "4",
language = "English",
volume = "22",
pages = "858--859",
booktitle = "Japanese Journal of Medical Electronics and Biological Engineering",
publisher = "Japan Soc of Medical Electronics & Biological Engineering",

}

TY - GEN

T1 - MODELING OF BIOMECHANICAL IMPEDANCE.

AU - Oka, Hisao

AU - Yamamoto, Tatsuma

PY - 1984/4

Y1 - 1984/4

N2 - A new model of biomechanical impedance is proposed which has only four independent parameters which express impedance characteristics under relatively low static pressure. This model is embodied in the form of both a mathematical expression and a mechanical circuit. It can be used to clarify the mechanical structure of biomaterials.

AB - A new model of biomechanical impedance is proposed which has only four independent parameters which express impedance characteristics under relatively low static pressure. This model is embodied in the form of both a mathematical expression and a mechanical circuit. It can be used to clarify the mechanical structure of biomaterials.

UR - http://www.scopus.com/inward/record.url?scp=0021407343&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0021407343&partnerID=8YFLogxK

M3 - Conference contribution

VL - 22

SP - 858

EP - 859

BT - Japanese Journal of Medical Electronics and Biological Engineering

PB - Japan Soc of Medical Electronics & Biological Engineering

ER -