Mid-range kHz electric resonance coupling wireless power tranfser

Hirokatsu Umegami, Masataka Ishihara, Fumiya Hattori, Mitsuru Masuda, Masayoshi Yamamoto, Kazuhiro Umetani

Research output: Chapter in Book/Report/Conference proceedingConference contribution

2 Citations (Scopus)

Abstract

This paper describes mid-range electrical resonance wireless power transfer in kHz range. Wireless power transfer using electrical field is minor since this method is understood only for close-range applications. However, our experimental units, the resonance frequency of which is 85 kHz, achieved 180 mm distance power transmission by vector network analyzer (VNA) measurement while keeping peak efficiency 68 %. In case of frequency response analyzer (FRA) measurement, the units can transfer power the most to the load at 300 mm but the efficiency is low. The closer the distance between the units, the better the efficiency is.

Original languageEnglish
Title of host publication2015 IEEE Energy Conversion Congress and Exposition, ECCE 2015
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages3197-3202
Number of pages6
ISBN (Print)9781467371506
DOIs
Publication statusPublished - Oct 27 2015
Event7th Annual IEEE Energy Conversion Congress and Exposition, ECCE 2015 - Montreal, Canada
Duration: Sep 20 2015Sep 24 2015

Other

Other7th Annual IEEE Energy Conversion Congress and Exposition, ECCE 2015
CountryCanada
CityMontreal
Period9/20/159/24/15

Fingerprint

Electric network analyzers
Power transmission
Frequency response

Keywords

  • Electrical Coupling
  • Electrical Resonance
  • kHz range
  • Mid-range WPT
  • Wireless Power Transfer

ASJC Scopus subject areas

  • Energy Engineering and Power Technology
  • Electrical and Electronic Engineering

Cite this

Umegami, H., Ishihara, M., Hattori, F., Masuda, M., Yamamoto, M., & Umetani, K. (2015). Mid-range kHz electric resonance coupling wireless power tranfser. In 2015 IEEE Energy Conversion Congress and Exposition, ECCE 2015 (pp. 3197-3202). [7310109] Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.1109/ECCE.2015.7310109

Mid-range kHz electric resonance coupling wireless power tranfser. / Umegami, Hirokatsu; Ishihara, Masataka; Hattori, Fumiya; Masuda, Mitsuru; Yamamoto, Masayoshi; Umetani, Kazuhiro.

2015 IEEE Energy Conversion Congress and Exposition, ECCE 2015. Institute of Electrical and Electronics Engineers Inc., 2015. p. 3197-3202 7310109.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Umegami, H, Ishihara, M, Hattori, F, Masuda, M, Yamamoto, M & Umetani, K 2015, Mid-range kHz electric resonance coupling wireless power tranfser. in 2015 IEEE Energy Conversion Congress and Exposition, ECCE 2015., 7310109, Institute of Electrical and Electronics Engineers Inc., pp. 3197-3202, 7th Annual IEEE Energy Conversion Congress and Exposition, ECCE 2015, Montreal, Canada, 9/20/15. https://doi.org/10.1109/ECCE.2015.7310109
Umegami H, Ishihara M, Hattori F, Masuda M, Yamamoto M, Umetani K. Mid-range kHz electric resonance coupling wireless power tranfser. In 2015 IEEE Energy Conversion Congress and Exposition, ECCE 2015. Institute of Electrical and Electronics Engineers Inc. 2015. p. 3197-3202. 7310109 https://doi.org/10.1109/ECCE.2015.7310109
Umegami, Hirokatsu ; Ishihara, Masataka ; Hattori, Fumiya ; Masuda, Mitsuru ; Yamamoto, Masayoshi ; Umetani, Kazuhiro. / Mid-range kHz electric resonance coupling wireless power tranfser. 2015 IEEE Energy Conversion Congress and Exposition, ECCE 2015. Institute of Electrical and Electronics Engineers Inc., 2015. pp. 3197-3202
@inproceedings{698529632fe54d1094a0ba3ade4678f1,
title = "Mid-range kHz electric resonance coupling wireless power tranfser",
abstract = "This paper describes mid-range electrical resonance wireless power transfer in kHz range. Wireless power transfer using electrical field is minor since this method is understood only for close-range applications. However, our experimental units, the resonance frequency of which is 85 kHz, achieved 180 mm distance power transmission by vector network analyzer (VNA) measurement while keeping peak efficiency 68 {\%}. In case of frequency response analyzer (FRA) measurement, the units can transfer power the most to the load at 300 mm but the efficiency is low. The closer the distance between the units, the better the efficiency is.",
keywords = "Electrical Coupling, Electrical Resonance, kHz range, Mid-range WPT, Wireless Power Transfer",
author = "Hirokatsu Umegami and Masataka Ishihara and Fumiya Hattori and Mitsuru Masuda and Masayoshi Yamamoto and Kazuhiro Umetani",
year = "2015",
month = "10",
day = "27",
doi = "10.1109/ECCE.2015.7310109",
language = "English",
isbn = "9781467371506",
pages = "3197--3202",
booktitle = "2015 IEEE Energy Conversion Congress and Exposition, ECCE 2015",
publisher = "Institute of Electrical and Electronics Engineers Inc.",

}

TY - GEN

T1 - Mid-range kHz electric resonance coupling wireless power tranfser

AU - Umegami, Hirokatsu

AU - Ishihara, Masataka

AU - Hattori, Fumiya

AU - Masuda, Mitsuru

AU - Yamamoto, Masayoshi

AU - Umetani, Kazuhiro

PY - 2015/10/27

Y1 - 2015/10/27

N2 - This paper describes mid-range electrical resonance wireless power transfer in kHz range. Wireless power transfer using electrical field is minor since this method is understood only for close-range applications. However, our experimental units, the resonance frequency of which is 85 kHz, achieved 180 mm distance power transmission by vector network analyzer (VNA) measurement while keeping peak efficiency 68 %. In case of frequency response analyzer (FRA) measurement, the units can transfer power the most to the load at 300 mm but the efficiency is low. The closer the distance between the units, the better the efficiency is.

AB - This paper describes mid-range electrical resonance wireless power transfer in kHz range. Wireless power transfer using electrical field is minor since this method is understood only for close-range applications. However, our experimental units, the resonance frequency of which is 85 kHz, achieved 180 mm distance power transmission by vector network analyzer (VNA) measurement while keeping peak efficiency 68 %. In case of frequency response analyzer (FRA) measurement, the units can transfer power the most to the load at 300 mm but the efficiency is low. The closer the distance between the units, the better the efficiency is.

KW - Electrical Coupling

KW - Electrical Resonance

KW - kHz range

KW - Mid-range WPT

KW - Wireless Power Transfer

UR - http://www.scopus.com/inward/record.url?scp=84963502526&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84963502526&partnerID=8YFLogxK

U2 - 10.1109/ECCE.2015.7310109

DO - 10.1109/ECCE.2015.7310109

M3 - Conference contribution

AN - SCOPUS:84963502526

SN - 9781467371506

SP - 3197

EP - 3202

BT - 2015 IEEE Energy Conversion Congress and Exposition, ECCE 2015

PB - Institute of Electrical and Electronics Engineers Inc.

ER -