Microheterogeneity of regional myocardial blood flows in low-perfused rat hearts evaluated by double-tracer digital radiography

Takeshi Matsumoto, Takahisa Asano, Mami Takemoto, Hiroyuki Tachibana, Yasuo Ogasawara, Fumihiko Kajiya

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

Using 3H- and 125I-labeled desmethylimipramine (DMI) for regional flow tracers, we established a two-time measurement method for the spatial pattern of myocardial perfusion in cross-circulated rat hearts. Myocardial extractions and retentions of these tracers were confirmed to be satisfactory; however, the latter were less than 90% after 3 min at a perfusion rate of 2.9 ml/min/g, limiting the present application to a short-time perfusion measurement. Distributions of myocardial depositions were separated by subtraction digital radiography with 400-μm pixel resolution. Its feasibility was examined by regression analysis between local deposition densities of 3H- and 125I-DMI injected simultaneously. The slope, y-intercept, and correlation coefficient (r) of the regression line were 0.98±0.04, 0.02±0.04, and 0.95±0.03, respectively, indicating the validity of the present image subtraction technique. The spatial pattern of myocardial perfusion in response to flow reduction was evaluated by the injections of 3H- and 125I-DMI, respectively, before and after a nearly 70% flow reduction. A significant correlation between normalized density distributions of these tracers was found in both subepicardium (r=0.77±0.12) and subendocardium (r=0.73±0.20), indicating the stable pattern of myocardial perfusion. However, the coefficient of variation of tracer densities showed a decrease of subendocardial flow heterogeneity from 35±15% to 31±16%. Thus, flow differences between originally high- and low-flow regions in subendocardium were reduced on a relative basis during low perfusion.

Original languageEnglish
Pages (from-to)910-917
Number of pages8
JournalApplied Radiation and Isotopes
Volume65
Issue number8
DOIs
Publication statusPublished - Aug 2007
Externally publishedYes

Fingerprint

radiography
blood flow
rats
tracers
subtraction
regression analysis
correlation coefficients
density distribution
pixels
time measurement
injection
slopes
coefficients

Keywords

  • Low perfusion
  • Microheterogeneity of flows
  • Molecular flow tracer
  • Myocardial retention
  • Quantitative digital radiography

ASJC Scopus subject areas

  • Radiation

Cite this

Microheterogeneity of regional myocardial blood flows in low-perfused rat hearts evaluated by double-tracer digital radiography. / Matsumoto, Takeshi; Asano, Takahisa; Takemoto, Mami; Tachibana, Hiroyuki; Ogasawara, Yasuo; Kajiya, Fumihiko.

In: Applied Radiation and Isotopes, Vol. 65, No. 8, 08.2007, p. 910-917.

Research output: Contribution to journalArticle

Matsumoto, Takeshi ; Asano, Takahisa ; Takemoto, Mami ; Tachibana, Hiroyuki ; Ogasawara, Yasuo ; Kajiya, Fumihiko. / Microheterogeneity of regional myocardial blood flows in low-perfused rat hearts evaluated by double-tracer digital radiography. In: Applied Radiation and Isotopes. 2007 ; Vol. 65, No. 8. pp. 910-917.
@article{fd7a99a1b43a42e396d87466ab2ad5f0,
title = "Microheterogeneity of regional myocardial blood flows in low-perfused rat hearts evaluated by double-tracer digital radiography",
abstract = "Using 3H- and 125I-labeled desmethylimipramine (DMI) for regional flow tracers, we established a two-time measurement method for the spatial pattern of myocardial perfusion in cross-circulated rat hearts. Myocardial extractions and retentions of these tracers were confirmed to be satisfactory; however, the latter were less than 90{\%} after 3 min at a perfusion rate of 2.9 ml/min/g, limiting the present application to a short-time perfusion measurement. Distributions of myocardial depositions were separated by subtraction digital radiography with 400-μm pixel resolution. Its feasibility was examined by regression analysis between local deposition densities of 3H- and 125I-DMI injected simultaneously. The slope, y-intercept, and correlation coefficient (r) of the regression line were 0.98±0.04, 0.02±0.04, and 0.95±0.03, respectively, indicating the validity of the present image subtraction technique. The spatial pattern of myocardial perfusion in response to flow reduction was evaluated by the injections of 3H- and 125I-DMI, respectively, before and after a nearly 70{\%} flow reduction. A significant correlation between normalized density distributions of these tracers was found in both subepicardium (r=0.77±0.12) and subendocardium (r=0.73±0.20), indicating the stable pattern of myocardial perfusion. However, the coefficient of variation of tracer densities showed a decrease of subendocardial flow heterogeneity from 35±15{\%} to 31±16{\%}. Thus, flow differences between originally high- and low-flow regions in subendocardium were reduced on a relative basis during low perfusion.",
keywords = "Low perfusion, Microheterogeneity of flows, Molecular flow tracer, Myocardial retention, Quantitative digital radiography",
author = "Takeshi Matsumoto and Takahisa Asano and Mami Takemoto and Hiroyuki Tachibana and Yasuo Ogasawara and Fumihiko Kajiya",
year = "2007",
month = "8",
doi = "10.1016/j.apradiso.2007.03.007",
language = "English",
volume = "65",
pages = "910--917",
journal = "Applied Radiation and Isotopes",
issn = "0969-8043",
publisher = "Elsevier Limited",
number = "8",

}

TY - JOUR

T1 - Microheterogeneity of regional myocardial blood flows in low-perfused rat hearts evaluated by double-tracer digital radiography

AU - Matsumoto, Takeshi

AU - Asano, Takahisa

AU - Takemoto, Mami

AU - Tachibana, Hiroyuki

AU - Ogasawara, Yasuo

AU - Kajiya, Fumihiko

PY - 2007/8

Y1 - 2007/8

N2 - Using 3H- and 125I-labeled desmethylimipramine (DMI) for regional flow tracers, we established a two-time measurement method for the spatial pattern of myocardial perfusion in cross-circulated rat hearts. Myocardial extractions and retentions of these tracers were confirmed to be satisfactory; however, the latter were less than 90% after 3 min at a perfusion rate of 2.9 ml/min/g, limiting the present application to a short-time perfusion measurement. Distributions of myocardial depositions were separated by subtraction digital radiography with 400-μm pixel resolution. Its feasibility was examined by regression analysis between local deposition densities of 3H- and 125I-DMI injected simultaneously. The slope, y-intercept, and correlation coefficient (r) of the regression line were 0.98±0.04, 0.02±0.04, and 0.95±0.03, respectively, indicating the validity of the present image subtraction technique. The spatial pattern of myocardial perfusion in response to flow reduction was evaluated by the injections of 3H- and 125I-DMI, respectively, before and after a nearly 70% flow reduction. A significant correlation between normalized density distributions of these tracers was found in both subepicardium (r=0.77±0.12) and subendocardium (r=0.73±0.20), indicating the stable pattern of myocardial perfusion. However, the coefficient of variation of tracer densities showed a decrease of subendocardial flow heterogeneity from 35±15% to 31±16%. Thus, flow differences between originally high- and low-flow regions in subendocardium were reduced on a relative basis during low perfusion.

AB - Using 3H- and 125I-labeled desmethylimipramine (DMI) for regional flow tracers, we established a two-time measurement method for the spatial pattern of myocardial perfusion in cross-circulated rat hearts. Myocardial extractions and retentions of these tracers were confirmed to be satisfactory; however, the latter were less than 90% after 3 min at a perfusion rate of 2.9 ml/min/g, limiting the present application to a short-time perfusion measurement. Distributions of myocardial depositions were separated by subtraction digital radiography with 400-μm pixel resolution. Its feasibility was examined by regression analysis between local deposition densities of 3H- and 125I-DMI injected simultaneously. The slope, y-intercept, and correlation coefficient (r) of the regression line were 0.98±0.04, 0.02±0.04, and 0.95±0.03, respectively, indicating the validity of the present image subtraction technique. The spatial pattern of myocardial perfusion in response to flow reduction was evaluated by the injections of 3H- and 125I-DMI, respectively, before and after a nearly 70% flow reduction. A significant correlation between normalized density distributions of these tracers was found in both subepicardium (r=0.77±0.12) and subendocardium (r=0.73±0.20), indicating the stable pattern of myocardial perfusion. However, the coefficient of variation of tracer densities showed a decrease of subendocardial flow heterogeneity from 35±15% to 31±16%. Thus, flow differences between originally high- and low-flow regions in subendocardium were reduced on a relative basis during low perfusion.

KW - Low perfusion

KW - Microheterogeneity of flows

KW - Molecular flow tracer

KW - Myocardial retention

KW - Quantitative digital radiography

UR - http://www.scopus.com/inward/record.url?scp=34547587900&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=34547587900&partnerID=8YFLogxK

U2 - 10.1016/j.apradiso.2007.03.007

DO - 10.1016/j.apradiso.2007.03.007

M3 - Article

C2 - 17574429

AN - SCOPUS:34547587900

VL - 65

SP - 910

EP - 917

JO - Applied Radiation and Isotopes

JF - Applied Radiation and Isotopes

SN - 0969-8043

IS - 8

ER -