Mechanical strengths of BaTiO3 thick films after dielectric breakdown

Akira Kishimoto, Kunihito Koumoto, Hiroaki Yanagida

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

Mechanical strengths of porous BaTiO3 thick films were measured after dielectric breakdown, the bending stress was applied to the position where the electric field had been applied. Comparison of the Weibull plots of mechanical strength between electrically failed and unfailed (as-sintered) specimens has shown that no damage due to dielectric breakdown occurred and that the poling process naturally involved in the dielectric strength measurement increased the mechanical strength. Mechanical strength before dielectric breakdown was estimated by taking into account this strengthening effect which depended on the poling voltage, time and temperature. A clear correlation between mechanical and dielectric strengths was obtained with the correlation coefficient of 0.73.

Original languageEnglish
Pages (from-to)847-851
Number of pages5
JournalNippon Seramikkusu Kyokai Gakujutsu Ronbunshi/Journal of the Ceramic Society of Japan
Volume96
Issue number8
Publication statusPublished - 1988
Externally publishedYes

Fingerprint

Electric breakdown
Thick films
thick films
Strength of materials
breakdown
Electric fields
correlation coefficients
Electric potential
plots
damage
electric fields
electric potential
Temperature

ASJC Scopus subject areas

  • Ceramics and Composites

Cite this

Mechanical strengths of BaTiO3 thick films after dielectric breakdown. / Kishimoto, Akira; Koumoto, Kunihito; Yanagida, Hiroaki.

In: Nippon Seramikkusu Kyokai Gakujutsu Ronbunshi/Journal of the Ceramic Society of Japan, Vol. 96, No. 8, 1988, p. 847-851.

Research output: Contribution to journalArticle

@article{e39df85e8b1d4a2ca640218801456274,
title = "Mechanical strengths of BaTiO3 thick films after dielectric breakdown",
abstract = "Mechanical strengths of porous BaTiO3 thick films were measured after dielectric breakdown, the bending stress was applied to the position where the electric field had been applied. Comparison of the Weibull plots of mechanical strength between electrically failed and unfailed (as-sintered) specimens has shown that no damage due to dielectric breakdown occurred and that the poling process naturally involved in the dielectric strength measurement increased the mechanical strength. Mechanical strength before dielectric breakdown was estimated by taking into account this strengthening effect which depended on the poling voltage, time and temperature. A clear correlation between mechanical and dielectric strengths was obtained with the correlation coefficient of 0.73.",
author = "Akira Kishimoto and Kunihito Koumoto and Hiroaki Yanagida",
year = "1988",
language = "English",
volume = "96",
pages = "847--851",
journal = "Nippon Seramikkusu Kyokai Gakujutsu Ronbunshi/Journal of the Ceramic Society of Japan",
issn = "1882-0743",
publisher = "Ceramic Society of Japan/Nippon Seramikkusu Kyokai",
number = "8",

}

TY - JOUR

T1 - Mechanical strengths of BaTiO3 thick films after dielectric breakdown

AU - Kishimoto, Akira

AU - Koumoto, Kunihito

AU - Yanagida, Hiroaki

PY - 1988

Y1 - 1988

N2 - Mechanical strengths of porous BaTiO3 thick films were measured after dielectric breakdown, the bending stress was applied to the position where the electric field had been applied. Comparison of the Weibull plots of mechanical strength between electrically failed and unfailed (as-sintered) specimens has shown that no damage due to dielectric breakdown occurred and that the poling process naturally involved in the dielectric strength measurement increased the mechanical strength. Mechanical strength before dielectric breakdown was estimated by taking into account this strengthening effect which depended on the poling voltage, time and temperature. A clear correlation between mechanical and dielectric strengths was obtained with the correlation coefficient of 0.73.

AB - Mechanical strengths of porous BaTiO3 thick films were measured after dielectric breakdown, the bending stress was applied to the position where the electric field had been applied. Comparison of the Weibull plots of mechanical strength between electrically failed and unfailed (as-sintered) specimens has shown that no damage due to dielectric breakdown occurred and that the poling process naturally involved in the dielectric strength measurement increased the mechanical strength. Mechanical strength before dielectric breakdown was estimated by taking into account this strengthening effect which depended on the poling voltage, time and temperature. A clear correlation between mechanical and dielectric strengths was obtained with the correlation coefficient of 0.73.

UR - http://www.scopus.com/inward/record.url?scp=0024128509&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0024128509&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:0024128509

VL - 96

SP - 847

EP - 851

JO - Nippon Seramikkusu Kyokai Gakujutsu Ronbunshi/Journal of the Ceramic Society of Japan

JF - Nippon Seramikkusu Kyokai Gakujutsu Ronbunshi/Journal of the Ceramic Society of Japan

SN - 1882-0743

IS - 8

ER -