Improvement of sensitivity for a compact magnetometer using HTS-SQUID with rotating sample

Daichi Hamasaki, Naohiro Okamoto, Mohd Mawardi Saari, Kenji Sakai, Toshihiko Kiwa, Keiji Tsukada

Research output: Contribution to journalArticle

Abstract

We have improved previously developed compact magnetometer using HTS-SQUID with rotating sample. In the previous system, the attenuation of rotating speed had resulted to the deformation of the averaged waveform signal, reducing the reproducibility in measurements. In this paper, we have used a more superior motor in order to decrease the attenuation of the rotational speed for the precise averaging of the output signal and improving the signal-to-noise ratio. Moreover, to improve sensitivity, we optimized the pickup coil and compared the signal-to-noise ratio of the circular and elliptical pickup coils which having the same number of turns, resistance and inductance. As a result, the signal-to-noise ratio was improved with high accuracy and the magnetometer showed susceptibility sensitivity of 3.8×10-9 emu.

Original languageEnglish
Pages (from-to)347-351
Number of pages5
JournalIEEJ Transactions on Fundamentals and Materials
Volume134
Issue number5
DOIs
Publication statusPublished - 2014

Fingerprint

SQUIDs
Magnetometers
Signal to noise ratio
Pickups
Inductance

Keywords

  • Diamagnetism
  • HTS-SQUID
  • Magnetometer
  • Rotating sample

ASJC Scopus subject areas

  • Electrical and Electronic Engineering

Cite this

Improvement of sensitivity for a compact magnetometer using HTS-SQUID with rotating sample. / Hamasaki, Daichi; Okamoto, Naohiro; Saari, Mohd Mawardi; Sakai, Kenji; Kiwa, Toshihiko; Tsukada, Keiji.

In: IEEJ Transactions on Fundamentals and Materials, Vol. 134, No. 5, 2014, p. 347-351.

Research output: Contribution to journalArticle

@article{ea136d1987214581a3fcabdc5497d01d,
title = "Improvement of sensitivity for a compact magnetometer using HTS-SQUID with rotating sample",
abstract = "We have improved previously developed compact magnetometer using HTS-SQUID with rotating sample. In the previous system, the attenuation of rotating speed had resulted to the deformation of the averaged waveform signal, reducing the reproducibility in measurements. In this paper, we have used a more superior motor in order to decrease the attenuation of the rotational speed for the precise averaging of the output signal and improving the signal-to-noise ratio. Moreover, to improve sensitivity, we optimized the pickup coil and compared the signal-to-noise ratio of the circular and elliptical pickup coils which having the same number of turns, resistance and inductance. As a result, the signal-to-noise ratio was improved with high accuracy and the magnetometer showed susceptibility sensitivity of 3.8×10-9 emu.",
keywords = "Diamagnetism, HTS-SQUID, Magnetometer, Rotating sample",
author = "Daichi Hamasaki and Naohiro Okamoto and Saari, {Mohd Mawardi} and Kenji Sakai and Toshihiko Kiwa and Keiji Tsukada",
year = "2014",
doi = "10.1541/ieejfms.134.347",
language = "English",
volume = "134",
pages = "347--351",
journal = "IEEJ Transactions on Fundamentals and Materials",
issn = "0385-4205",
publisher = "The Institute of Electrical Engineers of Japan",
number = "5",

}

TY - JOUR

T1 - Improvement of sensitivity for a compact magnetometer using HTS-SQUID with rotating sample

AU - Hamasaki, Daichi

AU - Okamoto, Naohiro

AU - Saari, Mohd Mawardi

AU - Sakai, Kenji

AU - Kiwa, Toshihiko

AU - Tsukada, Keiji

PY - 2014

Y1 - 2014

N2 - We have improved previously developed compact magnetometer using HTS-SQUID with rotating sample. In the previous system, the attenuation of rotating speed had resulted to the deformation of the averaged waveform signal, reducing the reproducibility in measurements. In this paper, we have used a more superior motor in order to decrease the attenuation of the rotational speed for the precise averaging of the output signal and improving the signal-to-noise ratio. Moreover, to improve sensitivity, we optimized the pickup coil and compared the signal-to-noise ratio of the circular and elliptical pickup coils which having the same number of turns, resistance and inductance. As a result, the signal-to-noise ratio was improved with high accuracy and the magnetometer showed susceptibility sensitivity of 3.8×10-9 emu.

AB - We have improved previously developed compact magnetometer using HTS-SQUID with rotating sample. In the previous system, the attenuation of rotating speed had resulted to the deformation of the averaged waveform signal, reducing the reproducibility in measurements. In this paper, we have used a more superior motor in order to decrease the attenuation of the rotational speed for the precise averaging of the output signal and improving the signal-to-noise ratio. Moreover, to improve sensitivity, we optimized the pickup coil and compared the signal-to-noise ratio of the circular and elliptical pickup coils which having the same number of turns, resistance and inductance. As a result, the signal-to-noise ratio was improved with high accuracy and the magnetometer showed susceptibility sensitivity of 3.8×10-9 emu.

KW - Diamagnetism

KW - HTS-SQUID

KW - Magnetometer

KW - Rotating sample

UR - http://www.scopus.com/inward/record.url?scp=84899864898&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84899864898&partnerID=8YFLogxK

U2 - 10.1541/ieejfms.134.347

DO - 10.1541/ieejfms.134.347

M3 - Article

AN - SCOPUS:84899864898

VL - 134

SP - 347

EP - 351

JO - IEEJ Transactions on Fundamentals and Materials

JF - IEEJ Transactions on Fundamentals and Materials

SN - 0385-4205

IS - 5