Impact of tissue photon attenuation in small animal cardiac PET imaging

Nobuyuki Hayakawa, Tomohiko Yamane, Anahi Paula Arias-Loza, Tetsuya Shinaji, Hiroshi Wakabayashi, Constantin Lapa, Rudolf A. Werner, Mehrbod S. Javadi, Theo Pelzer, Takahiro Higuchi

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

Objectives Tissue photon attenuation is one of the essential artifacts requiring correction in clinical cardiac positron emission tomography (PET) imaging. However, due to small body size its impact on diagnostic accuracy in small rodents is considered to be limited or even ignorable. The present cardiac PET study compares lean and obese rats to determine the influence of tissue attenuation on quantitative assessment as well as regional tracer distribution. Methods A dedicated small animal PET system equipped with a 57Co rotating source for transmission was used. To assess the impact of tissue attenuation in rats with different body sizes, cardiac 18F­FDG -PET studies for Zucker diabetic fatty rats (obese rats) and Zucker lean rats (lean rats) were performed. The radiotracer activity reduction by attenuation was compared between the two groups. Regional tracer distribution calculated with and without attenuation correction was also assessed. Results The chest diameter was significantly longer in obese than in lean rats (5.6 ± 0.3 cm in obese and 4.5 ± 0.2 cm in lean rats, p < 0.0001). Whereas the activity reduction by attenuation was significantly greater in obese than in lean rats (44.1 ± 2.5% and 5.1 ± 3.1%, p < 0.0001), the regional variation of tissue attenuation among the ventricular walls was minimal in both lean (p = 0.73) and obese rats (p = 0.65). Conclusion Attenuation correction is indispensable for accurate comparison of cardiac tracer activity between animals with different body size, whereas it can be omitted for evaluation of regional tracer distribution.

Original languageEnglish
Pages (from-to)257-260
Number of pages4
JournalInternational Journal of Cardiology
Volume227
DOIs
Publication statusPublished - Jan 15 2017
Externally publishedYes

Fingerprint

Photons
Positron-Emission Tomography
Body Size
Zucker Rats
Artifacts
Rodentia
Thorax

Keywords

  • Attenuation correction
  • Cardiac PET
  • Small animal
  • Tissue photon attenuation

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Cite this

Impact of tissue photon attenuation in small animal cardiac PET imaging. / Hayakawa, Nobuyuki; Yamane, Tomohiko; Arias-Loza, Anahi Paula; Shinaji, Tetsuya; Wakabayashi, Hiroshi; Lapa, Constantin; Werner, Rudolf A.; Javadi, Mehrbod S.; Pelzer, Theo; Higuchi, Takahiro.

In: International Journal of Cardiology, Vol. 227, 15.01.2017, p. 257-260.

Research output: Contribution to journalArticle

Hayakawa, N, Yamane, T, Arias-Loza, AP, Shinaji, T, Wakabayashi, H, Lapa, C, Werner, RA, Javadi, MS, Pelzer, T & Higuchi, T 2017, 'Impact of tissue photon attenuation in small animal cardiac PET imaging', International Journal of Cardiology, vol. 227, pp. 257-260. https://doi.org/10.1016/j.ijcard.2016.11.119
Hayakawa N, Yamane T, Arias-Loza AP, Shinaji T, Wakabayashi H, Lapa C et al. Impact of tissue photon attenuation in small animal cardiac PET imaging. International Journal of Cardiology. 2017 Jan 15;227:257-260. https://doi.org/10.1016/j.ijcard.2016.11.119
Hayakawa, Nobuyuki ; Yamane, Tomohiko ; Arias-Loza, Anahi Paula ; Shinaji, Tetsuya ; Wakabayashi, Hiroshi ; Lapa, Constantin ; Werner, Rudolf A. ; Javadi, Mehrbod S. ; Pelzer, Theo ; Higuchi, Takahiro. / Impact of tissue photon attenuation in small animal cardiac PET imaging. In: International Journal of Cardiology. 2017 ; Vol. 227. pp. 257-260.
@article{d6d8718b3edc424cbedd2a56ca523a92,
title = "Impact of tissue photon attenuation in small animal cardiac PET imaging",
abstract = "Objectives Tissue photon attenuation is one of the essential artifacts requiring correction in clinical cardiac positron emission tomography (PET) imaging. However, due to small body size its impact on diagnostic accuracy in small rodents is considered to be limited or even ignorable. The present cardiac PET study compares lean and obese rats to determine the influence of tissue attenuation on quantitative assessment as well as regional tracer distribution. Methods A dedicated small animal PET system equipped with a 57Co rotating source for transmission was used. To assess the impact of tissue attenuation in rats with different body sizes, cardiac 18F­FDG -PET studies for Zucker diabetic fatty rats (obese rats) and Zucker lean rats (lean rats) were performed. The radiotracer activity reduction by attenuation was compared between the two groups. Regional tracer distribution calculated with and without attenuation correction was also assessed. Results The chest diameter was significantly longer in obese than in lean rats (5.6 ± 0.3 cm in obese and 4.5 ± 0.2 cm in lean rats, p < 0.0001). Whereas the activity reduction by attenuation was significantly greater in obese than in lean rats (44.1 ± 2.5{\%} and 5.1 ± 3.1{\%}, p < 0.0001), the regional variation of tissue attenuation among the ventricular walls was minimal in both lean (p = 0.73) and obese rats (p = 0.65). Conclusion Attenuation correction is indispensable for accurate comparison of cardiac tracer activity between animals with different body size, whereas it can be omitted for evaluation of regional tracer distribution.",
keywords = "Attenuation correction, Cardiac PET, Small animal, Tissue photon attenuation",
author = "Nobuyuki Hayakawa and Tomohiko Yamane and Arias-Loza, {Anahi Paula} and Tetsuya Shinaji and Hiroshi Wakabayashi and Constantin Lapa and Werner, {Rudolf A.} and Javadi, {Mehrbod S.} and Theo Pelzer and Takahiro Higuchi",
year = "2017",
month = "1",
day = "15",
doi = "10.1016/j.ijcard.2016.11.119",
language = "English",
volume = "227",
pages = "257--260",
journal = "International Journal of Cardiology",
issn = "0167-5273",
publisher = "Elsevier Ireland Ltd",

}

TY - JOUR

T1 - Impact of tissue photon attenuation in small animal cardiac PET imaging

AU - Hayakawa, Nobuyuki

AU - Yamane, Tomohiko

AU - Arias-Loza, Anahi Paula

AU - Shinaji, Tetsuya

AU - Wakabayashi, Hiroshi

AU - Lapa, Constantin

AU - Werner, Rudolf A.

AU - Javadi, Mehrbod S.

AU - Pelzer, Theo

AU - Higuchi, Takahiro

PY - 2017/1/15

Y1 - 2017/1/15

N2 - Objectives Tissue photon attenuation is one of the essential artifacts requiring correction in clinical cardiac positron emission tomography (PET) imaging. However, due to small body size its impact on diagnostic accuracy in small rodents is considered to be limited or even ignorable. The present cardiac PET study compares lean and obese rats to determine the influence of tissue attenuation on quantitative assessment as well as regional tracer distribution. Methods A dedicated small animal PET system equipped with a 57Co rotating source for transmission was used. To assess the impact of tissue attenuation in rats with different body sizes, cardiac 18F­FDG -PET studies for Zucker diabetic fatty rats (obese rats) and Zucker lean rats (lean rats) were performed. The radiotracer activity reduction by attenuation was compared between the two groups. Regional tracer distribution calculated with and without attenuation correction was also assessed. Results The chest diameter was significantly longer in obese than in lean rats (5.6 ± 0.3 cm in obese and 4.5 ± 0.2 cm in lean rats, p < 0.0001). Whereas the activity reduction by attenuation was significantly greater in obese than in lean rats (44.1 ± 2.5% and 5.1 ± 3.1%, p < 0.0001), the regional variation of tissue attenuation among the ventricular walls was minimal in both lean (p = 0.73) and obese rats (p = 0.65). Conclusion Attenuation correction is indispensable for accurate comparison of cardiac tracer activity between animals with different body size, whereas it can be omitted for evaluation of regional tracer distribution.

AB - Objectives Tissue photon attenuation is one of the essential artifacts requiring correction in clinical cardiac positron emission tomography (PET) imaging. However, due to small body size its impact on diagnostic accuracy in small rodents is considered to be limited or even ignorable. The present cardiac PET study compares lean and obese rats to determine the influence of tissue attenuation on quantitative assessment as well as regional tracer distribution. Methods A dedicated small animal PET system equipped with a 57Co rotating source for transmission was used. To assess the impact of tissue attenuation in rats with different body sizes, cardiac 18F­FDG -PET studies for Zucker diabetic fatty rats (obese rats) and Zucker lean rats (lean rats) were performed. The radiotracer activity reduction by attenuation was compared between the two groups. Regional tracer distribution calculated with and without attenuation correction was also assessed. Results The chest diameter was significantly longer in obese than in lean rats (5.6 ± 0.3 cm in obese and 4.5 ± 0.2 cm in lean rats, p < 0.0001). Whereas the activity reduction by attenuation was significantly greater in obese than in lean rats (44.1 ± 2.5% and 5.1 ± 3.1%, p < 0.0001), the regional variation of tissue attenuation among the ventricular walls was minimal in both lean (p = 0.73) and obese rats (p = 0.65). Conclusion Attenuation correction is indispensable for accurate comparison of cardiac tracer activity between animals with different body size, whereas it can be omitted for evaluation of regional tracer distribution.

KW - Attenuation correction

KW - Cardiac PET

KW - Small animal

KW - Tissue photon attenuation

UR - http://www.scopus.com/inward/record.url?scp=85006077925&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85006077925&partnerID=8YFLogxK

U2 - 10.1016/j.ijcard.2016.11.119

DO - 10.1016/j.ijcard.2016.11.119

M3 - Article

C2 - 27839818

AN - SCOPUS:85006077925

VL - 227

SP - 257

EP - 260

JO - International Journal of Cardiology

JF - International Journal of Cardiology

SN - 0167-5273

ER -