Impact of multileaf collimator leaf positioning accuracy on intensity modulated radiation therapy.

Motoharu Sasaki, Masahide Tominaga, Hitoshi Ikushima, Taro Kishi, Tetsuya Kawashita, Yasuo Hara, Yukiko Fukunaga, Masashi Kimura, Yasufumi Shitakubo, Satoru Takashi, Masataka Oita

Research output: Contribution to journalArticle

Abstract

In multileaf collimator (MLC)-based intensity modulated radiation therapy (IMRT), the dose is influenced by the uncertainty of MLC driving control. In this study, we examined the influence of MLC driving control accuracy on dose evaluation (gamma analysis) by evaluating 60-day MLC driving control accuracy (stationary positioning accuracy and positioning reproducibility) once a week as well as measuring IMRT dose distribution. The MLC positioning accuracy accompanied variation over time and tended to expand by 0.1 to 0.15 mm in one week and about 1 mm in 60 days. In terms of reproducibility, errors were within 0.2 mm for more than 95%. For prostate IMRT, when MLC stationary positioning accuracy was around 1 mm, no significant difference was observed in the pass rate in gamma analysis. Therefore, the results suggest that regular maintenance by setting a permissible value determined by the MLC positioning accuracy test can be an effective indicator in the future for maintaining the safety of IMRT.

Original languageEnglish
Pages (from-to)497-506
Number of pages10
JournalNihon Hoshasen Gijutsu Gakkai zasshi
Volume67
Issue number5
Publication statusPublished - 2011
Externally publishedYes

Fingerprint

Radiotherapy
Uncertainty
Prostate
Maintenance
Safety

ASJC Scopus subject areas

  • Medicine(all)

Cite this

Sasaki, M., Tominaga, M., Ikushima, H., Kishi, T., Kawashita, T., Hara, Y., ... Oita, M. (2011). Impact of multileaf collimator leaf positioning accuracy on intensity modulated radiation therapy. Nihon Hoshasen Gijutsu Gakkai zasshi, 67(5), 497-506.

Impact of multileaf collimator leaf positioning accuracy on intensity modulated radiation therapy. / Sasaki, Motoharu; Tominaga, Masahide; Ikushima, Hitoshi; Kishi, Taro; Kawashita, Tetsuya; Hara, Yasuo; Fukunaga, Yukiko; Kimura, Masashi; Shitakubo, Yasufumi; Takashi, Satoru; Oita, Masataka.

In: Nihon Hoshasen Gijutsu Gakkai zasshi, Vol. 67, No. 5, 2011, p. 497-506.

Research output: Contribution to journalArticle

Sasaki, M, Tominaga, M, Ikushima, H, Kishi, T, Kawashita, T, Hara, Y, Fukunaga, Y, Kimura, M, Shitakubo, Y, Takashi, S & Oita, M 2011, 'Impact of multileaf collimator leaf positioning accuracy on intensity modulated radiation therapy.', Nihon Hoshasen Gijutsu Gakkai zasshi, vol. 67, no. 5, pp. 497-506.
Sasaki M, Tominaga M, Ikushima H, Kishi T, Kawashita T, Hara Y et al. Impact of multileaf collimator leaf positioning accuracy on intensity modulated radiation therapy. Nihon Hoshasen Gijutsu Gakkai zasshi. 2011;67(5):497-506.
Sasaki, Motoharu ; Tominaga, Masahide ; Ikushima, Hitoshi ; Kishi, Taro ; Kawashita, Tetsuya ; Hara, Yasuo ; Fukunaga, Yukiko ; Kimura, Masashi ; Shitakubo, Yasufumi ; Takashi, Satoru ; Oita, Masataka. / Impact of multileaf collimator leaf positioning accuracy on intensity modulated radiation therapy. In: Nihon Hoshasen Gijutsu Gakkai zasshi. 2011 ; Vol. 67, No. 5. pp. 497-506.
@article{2fa2068ed23846cbaaedf28193c3ff7d,
title = "Impact of multileaf collimator leaf positioning accuracy on intensity modulated radiation therapy.",
abstract = "In multileaf collimator (MLC)-based intensity modulated radiation therapy (IMRT), the dose is influenced by the uncertainty of MLC driving control. In this study, we examined the influence of MLC driving control accuracy on dose evaluation (gamma analysis) by evaluating 60-day MLC driving control accuracy (stationary positioning accuracy and positioning reproducibility) once a week as well as measuring IMRT dose distribution. The MLC positioning accuracy accompanied variation over time and tended to expand by 0.1 to 0.15 mm in one week and about 1 mm in 60 days. In terms of reproducibility, errors were within 0.2 mm for more than 95{\%}. For prostate IMRT, when MLC stationary positioning accuracy was around 1 mm, no significant difference was observed in the pass rate in gamma analysis. Therefore, the results suggest that regular maintenance by setting a permissible value determined by the MLC positioning accuracy test can be an effective indicator in the future for maintaining the safety of IMRT.",
author = "Motoharu Sasaki and Masahide Tominaga and Hitoshi Ikushima and Taro Kishi and Tetsuya Kawashita and Yasuo Hara and Yukiko Fukunaga and Masashi Kimura and Yasufumi Shitakubo and Satoru Takashi and Masataka Oita",
year = "2011",
language = "English",
volume = "67",
pages = "497--506",
journal = "Nippon Hoshasen Gijutsu Gakkai zasshi",
issn = "0369-4305",
publisher = "Nihon Hoshasen Gijutsu Gakkai/Japanese Society of Radiological Technology",
number = "5",

}

TY - JOUR

T1 - Impact of multileaf collimator leaf positioning accuracy on intensity modulated radiation therapy.

AU - Sasaki, Motoharu

AU - Tominaga, Masahide

AU - Ikushima, Hitoshi

AU - Kishi, Taro

AU - Kawashita, Tetsuya

AU - Hara, Yasuo

AU - Fukunaga, Yukiko

AU - Kimura, Masashi

AU - Shitakubo, Yasufumi

AU - Takashi, Satoru

AU - Oita, Masataka

PY - 2011

Y1 - 2011

N2 - In multileaf collimator (MLC)-based intensity modulated radiation therapy (IMRT), the dose is influenced by the uncertainty of MLC driving control. In this study, we examined the influence of MLC driving control accuracy on dose evaluation (gamma analysis) by evaluating 60-day MLC driving control accuracy (stationary positioning accuracy and positioning reproducibility) once a week as well as measuring IMRT dose distribution. The MLC positioning accuracy accompanied variation over time and tended to expand by 0.1 to 0.15 mm in one week and about 1 mm in 60 days. In terms of reproducibility, errors were within 0.2 mm for more than 95%. For prostate IMRT, when MLC stationary positioning accuracy was around 1 mm, no significant difference was observed in the pass rate in gamma analysis. Therefore, the results suggest that regular maintenance by setting a permissible value determined by the MLC positioning accuracy test can be an effective indicator in the future for maintaining the safety of IMRT.

AB - In multileaf collimator (MLC)-based intensity modulated radiation therapy (IMRT), the dose is influenced by the uncertainty of MLC driving control. In this study, we examined the influence of MLC driving control accuracy on dose evaluation (gamma analysis) by evaluating 60-day MLC driving control accuracy (stationary positioning accuracy and positioning reproducibility) once a week as well as measuring IMRT dose distribution. The MLC positioning accuracy accompanied variation over time and tended to expand by 0.1 to 0.15 mm in one week and about 1 mm in 60 days. In terms of reproducibility, errors were within 0.2 mm for more than 95%. For prostate IMRT, when MLC stationary positioning accuracy was around 1 mm, no significant difference was observed in the pass rate in gamma analysis. Therefore, the results suggest that regular maintenance by setting a permissible value determined by the MLC positioning accuracy test can be an effective indicator in the future for maintaining the safety of IMRT.

UR - http://www.scopus.com/inward/record.url?scp=84863934579&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84863934579&partnerID=8YFLogxK

M3 - Article

VL - 67

SP - 497

EP - 506

JO - Nippon Hoshasen Gijutsu Gakkai zasshi

JF - Nippon Hoshasen Gijutsu Gakkai zasshi

SN - 0369-4305

IS - 5

ER -