High spatial resolution MRA of renal arteries using contrast behavior between fat and water during transient phase before reaching a steady state

Katsuhiro Kida, Sachiko Goto, Yoshiharu Azuma

Research output: Contribution to journalArticle

Abstract

Purpose: Our aim is high spatial resolution imaging of maximum intensity projection (MIP) images in renal magnetic resonance angiography (MRA) by constructing a protocol for acquiring three-dimensional volume data with isotropic voxels. Materials and methods: We eliminated water-selective excitation (WATS) and utilized effective contrast behavior between fat and water before reaching a steady state - that is, during the transient phase - to cover fat suppression by WATS. In a phantom study, the optimal flip angle was investigated under the "low-high Y" profile order using distilled water and baby oil to construct a protocol with isotropic voxels. Signal intensity, contrast, noise and signal-to-noise ratio were investigated to compare image qualities between the conventional and the constructed isotropic protocols. In a clinical study, three radiologists and two radiological technologists visually evaluated clinical images of 20 volunteers for spatial resolution, contrast and overall reader confidence in two protocols. Results: We constructed an isotropic protocol with voxel dimensions of 0.78 mm × 0.78 mm × 0.78 mm at a flip angle of 90°. We maintained the scan time but enlarged the x-y pixel dimensions from 0.59 mm × 0.59 mm to 0.78 mm × 0.78 mm and shortened image height from 48 mm to 42.9 mm. Data from the phantom study were worse in the isotropic protocol than in the conventional protocol. However, overall reader confidence in the clinical images was significantly better in the isotropic protocol than in the conventional protocol (p <.001). Conclusion: Our study indicated the value of addressing high spatial resolution imaging of MIP images for renal MRA by constructing an isotropic protocol.

Original languageEnglish
Pages (from-to)846-850
Number of pages5
JournalEuropean Journal of Radiology
Volume81
Issue number5
DOIs
Publication statusPublished - May 2012

Fingerprint

Magnetic Resonance Angiography
Renal Artery
Fats
Water
Kidney
Signal-To-Noise Ratio
Noise
Volunteers
Oils

Keywords

  • High spatial resolution
  • Isotropic voxel
  • MIP image
  • Renal MRA
  • Transient phase
  • Visual evaluation

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

High spatial resolution MRA of renal arteries using contrast behavior between fat and water during transient phase before reaching a steady state. / Kida, Katsuhiro; Goto, Sachiko; Azuma, Yoshiharu.

In: European Journal of Radiology, Vol. 81, No. 5, 05.2012, p. 846-850.

Research output: Contribution to journalArticle

@article{5644439e90eb404e837a5d1046611b8c,
title = "High spatial resolution MRA of renal arteries using contrast behavior between fat and water during transient phase before reaching a steady state",
abstract = "Purpose: Our aim is high spatial resolution imaging of maximum intensity projection (MIP) images in renal magnetic resonance angiography (MRA) by constructing a protocol for acquiring three-dimensional volume data with isotropic voxels. Materials and methods: We eliminated water-selective excitation (WATS) and utilized effective contrast behavior between fat and water before reaching a steady state - that is, during the transient phase - to cover fat suppression by WATS. In a phantom study, the optimal flip angle was investigated under the {"}low-high Y{"} profile order using distilled water and baby oil to construct a protocol with isotropic voxels. Signal intensity, contrast, noise and signal-to-noise ratio were investigated to compare image qualities between the conventional and the constructed isotropic protocols. In a clinical study, three radiologists and two radiological technologists visually evaluated clinical images of 20 volunteers for spatial resolution, contrast and overall reader confidence in two protocols. Results: We constructed an isotropic protocol with voxel dimensions of 0.78 mm × 0.78 mm × 0.78 mm at a flip angle of 90°. We maintained the scan time but enlarged the x-y pixel dimensions from 0.59 mm × 0.59 mm to 0.78 mm × 0.78 mm and shortened image height from 48 mm to 42.9 mm. Data from the phantom study were worse in the isotropic protocol than in the conventional protocol. However, overall reader confidence in the clinical images was significantly better in the isotropic protocol than in the conventional protocol (p <.001). Conclusion: Our study indicated the value of addressing high spatial resolution imaging of MIP images for renal MRA by constructing an isotropic protocol.",
keywords = "High spatial resolution, Isotropic voxel, MIP image, Renal MRA, Transient phase, Visual evaluation",
author = "Katsuhiro Kida and Sachiko Goto and Yoshiharu Azuma",
year = "2012",
month = "5",
doi = "10.1016/j.ejrad.2011.02.031",
language = "English",
volume = "81",
pages = "846--850",
journal = "Journal of Medical Imaging",
issn = "0720-048X",
publisher = "Elsevier Ireland Ltd",
number = "5",

}

TY - JOUR

T1 - High spatial resolution MRA of renal arteries using contrast behavior between fat and water during transient phase before reaching a steady state

AU - Kida, Katsuhiro

AU - Goto, Sachiko

AU - Azuma, Yoshiharu

PY - 2012/5

Y1 - 2012/5

N2 - Purpose: Our aim is high spatial resolution imaging of maximum intensity projection (MIP) images in renal magnetic resonance angiography (MRA) by constructing a protocol for acquiring three-dimensional volume data with isotropic voxels. Materials and methods: We eliminated water-selective excitation (WATS) and utilized effective contrast behavior between fat and water before reaching a steady state - that is, during the transient phase - to cover fat suppression by WATS. In a phantom study, the optimal flip angle was investigated under the "low-high Y" profile order using distilled water and baby oil to construct a protocol with isotropic voxels. Signal intensity, contrast, noise and signal-to-noise ratio were investigated to compare image qualities between the conventional and the constructed isotropic protocols. In a clinical study, three radiologists and two radiological technologists visually evaluated clinical images of 20 volunteers for spatial resolution, contrast and overall reader confidence in two protocols. Results: We constructed an isotropic protocol with voxel dimensions of 0.78 mm × 0.78 mm × 0.78 mm at a flip angle of 90°. We maintained the scan time but enlarged the x-y pixel dimensions from 0.59 mm × 0.59 mm to 0.78 mm × 0.78 mm and shortened image height from 48 mm to 42.9 mm. Data from the phantom study were worse in the isotropic protocol than in the conventional protocol. However, overall reader confidence in the clinical images was significantly better in the isotropic protocol than in the conventional protocol (p <.001). Conclusion: Our study indicated the value of addressing high spatial resolution imaging of MIP images for renal MRA by constructing an isotropic protocol.

AB - Purpose: Our aim is high spatial resolution imaging of maximum intensity projection (MIP) images in renal magnetic resonance angiography (MRA) by constructing a protocol for acquiring three-dimensional volume data with isotropic voxels. Materials and methods: We eliminated water-selective excitation (WATS) and utilized effective contrast behavior between fat and water before reaching a steady state - that is, during the transient phase - to cover fat suppression by WATS. In a phantom study, the optimal flip angle was investigated under the "low-high Y" profile order using distilled water and baby oil to construct a protocol with isotropic voxels. Signal intensity, contrast, noise and signal-to-noise ratio were investigated to compare image qualities between the conventional and the constructed isotropic protocols. In a clinical study, three radiologists and two radiological technologists visually evaluated clinical images of 20 volunteers for spatial resolution, contrast and overall reader confidence in two protocols. Results: We constructed an isotropic protocol with voxel dimensions of 0.78 mm × 0.78 mm × 0.78 mm at a flip angle of 90°. We maintained the scan time but enlarged the x-y pixel dimensions from 0.59 mm × 0.59 mm to 0.78 mm × 0.78 mm and shortened image height from 48 mm to 42.9 mm. Data from the phantom study were worse in the isotropic protocol than in the conventional protocol. However, overall reader confidence in the clinical images was significantly better in the isotropic protocol than in the conventional protocol (p <.001). Conclusion: Our study indicated the value of addressing high spatial resolution imaging of MIP images for renal MRA by constructing an isotropic protocol.

KW - High spatial resolution

KW - Isotropic voxel

KW - MIP image

KW - Renal MRA

KW - Transient phase

KW - Visual evaluation

UR - http://www.scopus.com/inward/record.url?scp=84859960577&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84859960577&partnerID=8YFLogxK

U2 - 10.1016/j.ejrad.2011.02.031

DO - 10.1016/j.ejrad.2011.02.031

M3 - Article

C2 - 21429683

AN - SCOPUS:84859960577

VL - 81

SP - 846

EP - 850

JO - Journal of Medical Imaging

JF - Journal of Medical Imaging

SN - 0720-048X

IS - 5

ER -