In this study, the performances of the TinyPump (priming volume 5 mL) system including the pediatric cannulae (Stöckert Pediatric Arterial Cannulae 2.6, 3.0, and 4.0 mm, Stöckert Instruments GmbH, Munich, Germany; Polystan 20-Fr Venous Catheter, MAQUET GmbH, Rastatt, Germany) and an oxygenator (Terumo Capiox RX05 Baby-RX, Terumo Cardiovascular Systems Co., Tokyo, Japan) were studied in vitro followed with preliminary ex vivo studies in 20-kg piglets. In vitro results revealed that the TinyPump system met the requirements for pump speed, pump flow, and pressure drop as extracorporeal circulatory support during open heart surgery and extracorporeal membrane oxygenation (ECMO) in pediatric patients. In 2-h ex vivo studies using 20-kg piglets where the blood contacting surface of the TinyPump was coated with a biocompatible phospholipid polymer, the plasma-free hemoglobin levels remained less than 5.0 mg/dL and no thrombus formation was observed inside the pump. The TinyPump system including the oxygenator and connecting circuits resulted in an overall priming volume of 68 mL, the smallest ever reported. The TinyPump can be a safe option for pediatric circulatory support during open heart surgery and ECMO without requiring blood transfusion.

Original languageEnglish
Pages (from-to)408-412
Number of pages5
JournalArtificial Organs
Volume31
Issue number5
DOIs
Publication statusPublished - May 2007

Fingerprint

Pediatrics
Blood
Pumps
Oxygenators
Extracorporeal Membrane Oxygenation
Thoracic Surgery
Oxygenation
Germany
Surgery
Tokyo
Cardiovascular System
Membranes
Cardiovascular system
Blood Transfusion
Catheters
Hemoglobin
Phospholipids
Japan
Polymers
Hemoglobins

Keywords

  • Cardiopulmonary bypass
  • Centrifugal blood pump
  • Extracorporeal membrane oxygenation
  • Pediatric circulatory support
  • Ventricular assist device

ASJC Scopus subject areas

  • Biophysics

Cite this

Ohuchi, K., Hoshi, H., Iwasaki, Y., Ishihara, K., Yoshikawa, M., Ugaki, S., ... Takatani, S. (2007). Feasibility of a tiny centrifugal blood pump (TinyPump) for pediatric extracorporeal circulatory support. Artificial Organs, 31(5), 408-412. https://doi.org/10.1111/j.1525-1594.2007.00401.x

Feasibility of a tiny centrifugal blood pump (TinyPump) for pediatric extracorporeal circulatory support. / Ohuchi, Katsuhiro; Hoshi, Hideo; Iwasaki, Yasuhiko; Ishihara, Kazuhiko; Yoshikawa, Masaharu; Ugaki, Shinya; Ishino, Kozo; Osaki, Satoru; Kotani, Yasuhiro; Sano, Shunji; Takatani, Setsuo.

In: Artificial Organs, Vol. 31, No. 5, 05.2007, p. 408-412.

Research output: Contribution to journalArticle

Ohuchi, K, Hoshi, H, Iwasaki, Y, Ishihara, K, Yoshikawa, M, Ugaki, S, Ishino, K, Osaki, S, Kotani, Y, Sano, S & Takatani, S 2007, 'Feasibility of a tiny centrifugal blood pump (TinyPump) for pediatric extracorporeal circulatory support', Artificial Organs, vol. 31, no. 5, pp. 408-412. https://doi.org/10.1111/j.1525-1594.2007.00401.x
Ohuchi, Katsuhiro ; Hoshi, Hideo ; Iwasaki, Yasuhiko ; Ishihara, Kazuhiko ; Yoshikawa, Masaharu ; Ugaki, Shinya ; Ishino, Kozo ; Osaki, Satoru ; Kotani, Yasuhiro ; Sano, Shunji ; Takatani, Setsuo. / Feasibility of a tiny centrifugal blood pump (TinyPump) for pediatric extracorporeal circulatory support. In: Artificial Organs. 2007 ; Vol. 31, No. 5. pp. 408-412.
@article{7abab940ecfb472b99be66a86b291ec1,
title = "Feasibility of a tiny centrifugal blood pump (TinyPump) for pediatric extracorporeal circulatory support",
abstract = "In this study, the performances of the TinyPump (priming volume 5 mL) system including the pediatric cannulae (St{\"o}ckert Pediatric Arterial Cannulae 2.6, 3.0, and 4.0 mm, St{\"o}ckert Instruments GmbH, Munich, Germany; Polystan 20-Fr Venous Catheter, MAQUET GmbH, Rastatt, Germany) and an oxygenator (Terumo Capiox RX05 Baby-RX, Terumo Cardiovascular Systems Co., Tokyo, Japan) were studied in vitro followed with preliminary ex vivo studies in 20-kg piglets. In vitro results revealed that the TinyPump system met the requirements for pump speed, pump flow, and pressure drop as extracorporeal circulatory support during open heart surgery and extracorporeal membrane oxygenation (ECMO) in pediatric patients. In 2-h ex vivo studies using 20-kg piglets where the blood contacting surface of the TinyPump was coated with a biocompatible phospholipid polymer, the plasma-free hemoglobin levels remained less than 5.0 mg/dL and no thrombus formation was observed inside the pump. The TinyPump system including the oxygenator and connecting circuits resulted in an overall priming volume of 68 mL, the smallest ever reported. The TinyPump can be a safe option for pediatric circulatory support during open heart surgery and ECMO without requiring blood transfusion.",
keywords = "Cardiopulmonary bypass, Centrifugal blood pump, Extracorporeal membrane oxygenation, Pediatric circulatory support, Ventricular assist device",
author = "Katsuhiro Ohuchi and Hideo Hoshi and Yasuhiko Iwasaki and Kazuhiko Ishihara and Masaharu Yoshikawa and Shinya Ugaki and Kozo Ishino and Satoru Osaki and Yasuhiro Kotani and Shunji Sano and Setsuo Takatani",
year = "2007",
month = "5",
doi = "10.1111/j.1525-1594.2007.00401.x",
language = "English",
volume = "31",
pages = "408--412",
journal = "Artificial Organs",
issn = "0160-564X",
publisher = "Wiley-Blackwell",
number = "5",

}

TY - JOUR

T1 - Feasibility of a tiny centrifugal blood pump (TinyPump) for pediatric extracorporeal circulatory support

AU - Ohuchi, Katsuhiro

AU - Hoshi, Hideo

AU - Iwasaki, Yasuhiko

AU - Ishihara, Kazuhiko

AU - Yoshikawa, Masaharu

AU - Ugaki, Shinya

AU - Ishino, Kozo

AU - Osaki, Satoru

AU - Kotani, Yasuhiro

AU - Sano, Shunji

AU - Takatani, Setsuo

PY - 2007/5

Y1 - 2007/5

N2 - In this study, the performances of the TinyPump (priming volume 5 mL) system including the pediatric cannulae (Stöckert Pediatric Arterial Cannulae 2.6, 3.0, and 4.0 mm, Stöckert Instruments GmbH, Munich, Germany; Polystan 20-Fr Venous Catheter, MAQUET GmbH, Rastatt, Germany) and an oxygenator (Terumo Capiox RX05 Baby-RX, Terumo Cardiovascular Systems Co., Tokyo, Japan) were studied in vitro followed with preliminary ex vivo studies in 20-kg piglets. In vitro results revealed that the TinyPump system met the requirements for pump speed, pump flow, and pressure drop as extracorporeal circulatory support during open heart surgery and extracorporeal membrane oxygenation (ECMO) in pediatric patients. In 2-h ex vivo studies using 20-kg piglets where the blood contacting surface of the TinyPump was coated with a biocompatible phospholipid polymer, the plasma-free hemoglobin levels remained less than 5.0 mg/dL and no thrombus formation was observed inside the pump. The TinyPump system including the oxygenator and connecting circuits resulted in an overall priming volume of 68 mL, the smallest ever reported. The TinyPump can be a safe option for pediatric circulatory support during open heart surgery and ECMO without requiring blood transfusion.

AB - In this study, the performances of the TinyPump (priming volume 5 mL) system including the pediatric cannulae (Stöckert Pediatric Arterial Cannulae 2.6, 3.0, and 4.0 mm, Stöckert Instruments GmbH, Munich, Germany; Polystan 20-Fr Venous Catheter, MAQUET GmbH, Rastatt, Germany) and an oxygenator (Terumo Capiox RX05 Baby-RX, Terumo Cardiovascular Systems Co., Tokyo, Japan) were studied in vitro followed with preliminary ex vivo studies in 20-kg piglets. In vitro results revealed that the TinyPump system met the requirements for pump speed, pump flow, and pressure drop as extracorporeal circulatory support during open heart surgery and extracorporeal membrane oxygenation (ECMO) in pediatric patients. In 2-h ex vivo studies using 20-kg piglets where the blood contacting surface of the TinyPump was coated with a biocompatible phospholipid polymer, the plasma-free hemoglobin levels remained less than 5.0 mg/dL and no thrombus formation was observed inside the pump. The TinyPump system including the oxygenator and connecting circuits resulted in an overall priming volume of 68 mL, the smallest ever reported. The TinyPump can be a safe option for pediatric circulatory support during open heart surgery and ECMO without requiring blood transfusion.

KW - Cardiopulmonary bypass

KW - Centrifugal blood pump

KW - Extracorporeal membrane oxygenation

KW - Pediatric circulatory support

KW - Ventricular assist device

UR - http://www.scopus.com/inward/record.url?scp=34247612585&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=34247612585&partnerID=8YFLogxK

U2 - 10.1111/j.1525-1594.2007.00401.x

DO - 10.1111/j.1525-1594.2007.00401.x

M3 - Article

C2 - 17470213

AN - SCOPUS:34247612585

VL - 31

SP - 408

EP - 412

JO - Artificial Organs

JF - Artificial Organs

SN - 0160-564X

IS - 5

ER -