Electronic gradiometer in cylindrical magnetic shield for compact magnetocardiograph

A. Tsukamoto, K. Saitoh, K. Takagi, K. Yokosawa, D. Suzuki, K. Ogata, T. Miyashita, A. Kandori, Keiji Tsukada

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

An electronic first-order gradiometer in a cylindrical magnetic shield was investigated. The planar gradiometer exhibited better noise reduction performance than the axial gradiometer inside the cylindrical magnetic shield. This improvement was attributed to the anisotropic distribution of the magnetic field inside the cylindrical magnetic shield.

Original languageEnglish
Pages (from-to)5080-5082
Number of pages3
JournalApplied Physics Letters
Volume83
Issue number24
DOIs
Publication statusPublished - Dec 15 2003
Externally publishedYes

Fingerprint

gradiometers
electronics
noise reduction
magnetic fields

ASJC Scopus subject areas

  • Physics and Astronomy (miscellaneous)

Cite this

Tsukamoto, A., Saitoh, K., Takagi, K., Yokosawa, K., Suzuki, D., Ogata, K., ... Tsukada, K. (2003). Electronic gradiometer in cylindrical magnetic shield for compact magnetocardiograph. Applied Physics Letters, 83(24), 5080-5082. https://doi.org/10.1063/1.1630379

Electronic gradiometer in cylindrical magnetic shield for compact magnetocardiograph. / Tsukamoto, A.; Saitoh, K.; Takagi, K.; Yokosawa, K.; Suzuki, D.; Ogata, K.; Miyashita, T.; Kandori, A.; Tsukada, Keiji.

In: Applied Physics Letters, Vol. 83, No. 24, 15.12.2003, p. 5080-5082.

Research output: Contribution to journalArticle

Tsukamoto, A, Saitoh, K, Takagi, K, Yokosawa, K, Suzuki, D, Ogata, K, Miyashita, T, Kandori, A & Tsukada, K 2003, 'Electronic gradiometer in cylindrical magnetic shield for compact magnetocardiograph', Applied Physics Letters, vol. 83, no. 24, pp. 5080-5082. https://doi.org/10.1063/1.1630379
Tsukamoto A, Saitoh K, Takagi K, Yokosawa K, Suzuki D, Ogata K et al. Electronic gradiometer in cylindrical magnetic shield for compact magnetocardiograph. Applied Physics Letters. 2003 Dec 15;83(24):5080-5082. https://doi.org/10.1063/1.1630379
Tsukamoto, A. ; Saitoh, K. ; Takagi, K. ; Yokosawa, K. ; Suzuki, D. ; Ogata, K. ; Miyashita, T. ; Kandori, A. ; Tsukada, Keiji. / Electronic gradiometer in cylindrical magnetic shield for compact magnetocardiograph. In: Applied Physics Letters. 2003 ; Vol. 83, No. 24. pp. 5080-5082.
@article{85fabaace4244f12b7a9409acf17b3a9,
title = "Electronic gradiometer in cylindrical magnetic shield for compact magnetocardiograph",
abstract = "An electronic first-order gradiometer in a cylindrical magnetic shield was investigated. The planar gradiometer exhibited better noise reduction performance than the axial gradiometer inside the cylindrical magnetic shield. This improvement was attributed to the anisotropic distribution of the magnetic field inside the cylindrical magnetic shield.",
author = "A. Tsukamoto and K. Saitoh and K. Takagi and K. Yokosawa and D. Suzuki and K. Ogata and T. Miyashita and A. Kandori and Keiji Tsukada",
year = "2003",
month = "12",
day = "15",
doi = "10.1063/1.1630379",
language = "English",
volume = "83",
pages = "5080--5082",
journal = "Applied Physics Letters",
issn = "0003-6951",
publisher = "American Institute of Physics Publising LLC",
number = "24",

}

TY - JOUR

T1 - Electronic gradiometer in cylindrical magnetic shield for compact magnetocardiograph

AU - Tsukamoto, A.

AU - Saitoh, K.

AU - Takagi, K.

AU - Yokosawa, K.

AU - Suzuki, D.

AU - Ogata, K.

AU - Miyashita, T.

AU - Kandori, A.

AU - Tsukada, Keiji

PY - 2003/12/15

Y1 - 2003/12/15

N2 - An electronic first-order gradiometer in a cylindrical magnetic shield was investigated. The planar gradiometer exhibited better noise reduction performance than the axial gradiometer inside the cylindrical magnetic shield. This improvement was attributed to the anisotropic distribution of the magnetic field inside the cylindrical magnetic shield.

AB - An electronic first-order gradiometer in a cylindrical magnetic shield was investigated. The planar gradiometer exhibited better noise reduction performance than the axial gradiometer inside the cylindrical magnetic shield. This improvement was attributed to the anisotropic distribution of the magnetic field inside the cylindrical magnetic shield.

UR - http://www.scopus.com/inward/record.url?scp=0346669749&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0346669749&partnerID=8YFLogxK

U2 - 10.1063/1.1630379

DO - 10.1063/1.1630379

M3 - Article

VL - 83

SP - 5080

EP - 5082

JO - Applied Physics Letters

JF - Applied Physics Letters

SN - 0003-6951

IS - 24

ER -