Effects of structural orientation of enamel and dentine on light attenuation and local refractive index: An optical coherence tomography study

Ilnaz Hariri, Alireza Sadr, Yasushi Shimada, Junji Tagami, Yasunori Sumi

Research output: Contribution to journalArticle

70 Citations (Scopus)

Abstract

Objectives: To investigate optical properties of human enamel and dentine in relationship to structural orientation of enamel prisms and dentinal tubules by optical coherence tomography (OCT). Methods: Discs of 300-400 μm thickness including enamel with cross-cut or long-cut prisms and mid-coronal dentine with cross-cut, long-cut or oblique-cut tubules were obtained from 28 non-carious freshly extracted human third molars sectioned at different directions. Each disc was placed over a metal plate and B-scan images were obtained by a swept-source OCT at 1330 nm centre wavelength (Dental SS-OCT Prototype 1, Panasonic Healthcare Co., Ltd, Japan). Refractive index (n) calculated from optical path length and real thickness, and OCT signal slope (OCTSS) in relation to structural orientation were statistically compared among groups (α = 0.05). The discs were sectioned and observed under SEM to confirm prism or tubule orientations. Results: No significant differences were found in n and OCTSS among cross-cut and long-cut enamel groups (p > 0.05). However, in dentine, there was a significant difference in both variables among different regions. In cross-cut tubule orientation, the average n and OCTSS values were significantly lower compared to other two groups (long-cut and oblique-cut) (p < 0.05). There was a significant difference in both variables between enamel and dentine (p < 0.05). Conclusions: Unlike enamel, refractive index and OCT signal patterns in dentine vary according to structural orientation, with dentine tubules playing the role. Attenuation of OCT signal intensity was small in enamel. The findings may contribute to a better understanding of the interactions of light with the dental tissue. Clinical significance: Precise records of refractive indices and OCT signal patterns may be important for clinical diagnosis of caries and measurement of structural depth for operative purposes using this technology. Effects of dentine structural orientation on refractive index and scattering pattern must be considered when observing human teeth by OCT cross-sectional imaging.

Original languageEnglish
Pages (from-to)387-396
Number of pages10
JournalJournal of Dentistry
Volume40
Issue number5
DOIs
Publication statusPublished - May 2012
Externally publishedYes

Fingerprint

Refractometry
Optical Coherence Tomography
Dentin
Dental Enamel
Light
Tooth
Third Molar
Japan
Metals
Technology
Delivery of Health Care

Keywords

  • Attenuation
  • Dentine tubule
  • Enamel prisms
  • OCT
  • Refractive index
  • Tissue characterisation

ASJC Scopus subject areas

  • Dentistry(all)

Cite this

Effects of structural orientation of enamel and dentine on light attenuation and local refractive index : An optical coherence tomography study. / Hariri, Ilnaz; Sadr, Alireza; Shimada, Yasushi; Tagami, Junji; Sumi, Yasunori.

In: Journal of Dentistry, Vol. 40, No. 5, 05.2012, p. 387-396.

Research output: Contribution to journalArticle

@article{5a2d8783c7ec47c982e7022d21c38933,
title = "Effects of structural orientation of enamel and dentine on light attenuation and local refractive index: An optical coherence tomography study",
abstract = "Objectives: To investigate optical properties of human enamel and dentine in relationship to structural orientation of enamel prisms and dentinal tubules by optical coherence tomography (OCT). Methods: Discs of 300-400 μm thickness including enamel with cross-cut or long-cut prisms and mid-coronal dentine with cross-cut, long-cut or oblique-cut tubules were obtained from 28 non-carious freshly extracted human third molars sectioned at different directions. Each disc was placed over a metal plate and B-scan images were obtained by a swept-source OCT at 1330 nm centre wavelength (Dental SS-OCT Prototype 1, Panasonic Healthcare Co., Ltd, Japan). Refractive index (n) calculated from optical path length and real thickness, and OCT signal slope (OCTSS) in relation to structural orientation were statistically compared among groups (α = 0.05). The discs were sectioned and observed under SEM to confirm prism or tubule orientations. Results: No significant differences were found in n and OCTSS among cross-cut and long-cut enamel groups (p > 0.05). However, in dentine, there was a significant difference in both variables among different regions. In cross-cut tubule orientation, the average n and OCTSS values were significantly lower compared to other two groups (long-cut and oblique-cut) (p < 0.05). There was a significant difference in both variables between enamel and dentine (p < 0.05). Conclusions: Unlike enamel, refractive index and OCT signal patterns in dentine vary according to structural orientation, with dentine tubules playing the role. Attenuation of OCT signal intensity was small in enamel. The findings may contribute to a better understanding of the interactions of light with the dental tissue. Clinical significance: Precise records of refractive indices and OCT signal patterns may be important for clinical diagnosis of caries and measurement of structural depth for operative purposes using this technology. Effects of dentine structural orientation on refractive index and scattering pattern must be considered when observing human teeth by OCT cross-sectional imaging.",
keywords = "Attenuation, Dentine tubule, Enamel prisms, OCT, Refractive index, Tissue characterisation",
author = "Ilnaz Hariri and Alireza Sadr and Yasushi Shimada and Junji Tagami and Yasunori Sumi",
year = "2012",
month = "5",
doi = "10.1016/j.jdent.2012.01.017",
language = "English",
volume = "40",
pages = "387--396",
journal = "Journal of Dentistry",
issn = "0300-5712",
publisher = "Elsevier BV",
number = "5",

}

TY - JOUR

T1 - Effects of structural orientation of enamel and dentine on light attenuation and local refractive index

T2 - An optical coherence tomography study

AU - Hariri, Ilnaz

AU - Sadr, Alireza

AU - Shimada, Yasushi

AU - Tagami, Junji

AU - Sumi, Yasunori

PY - 2012/5

Y1 - 2012/5

N2 - Objectives: To investigate optical properties of human enamel and dentine in relationship to structural orientation of enamel prisms and dentinal tubules by optical coherence tomography (OCT). Methods: Discs of 300-400 μm thickness including enamel with cross-cut or long-cut prisms and mid-coronal dentine with cross-cut, long-cut or oblique-cut tubules were obtained from 28 non-carious freshly extracted human third molars sectioned at different directions. Each disc was placed over a metal plate and B-scan images were obtained by a swept-source OCT at 1330 nm centre wavelength (Dental SS-OCT Prototype 1, Panasonic Healthcare Co., Ltd, Japan). Refractive index (n) calculated from optical path length and real thickness, and OCT signal slope (OCTSS) in relation to structural orientation were statistically compared among groups (α = 0.05). The discs were sectioned and observed under SEM to confirm prism or tubule orientations. Results: No significant differences were found in n and OCTSS among cross-cut and long-cut enamel groups (p > 0.05). However, in dentine, there was a significant difference in both variables among different regions. In cross-cut tubule orientation, the average n and OCTSS values were significantly lower compared to other two groups (long-cut and oblique-cut) (p < 0.05). There was a significant difference in both variables between enamel and dentine (p < 0.05). Conclusions: Unlike enamel, refractive index and OCT signal patterns in dentine vary according to structural orientation, with dentine tubules playing the role. Attenuation of OCT signal intensity was small in enamel. The findings may contribute to a better understanding of the interactions of light with the dental tissue. Clinical significance: Precise records of refractive indices and OCT signal patterns may be important for clinical diagnosis of caries and measurement of structural depth for operative purposes using this technology. Effects of dentine structural orientation on refractive index and scattering pattern must be considered when observing human teeth by OCT cross-sectional imaging.

AB - Objectives: To investigate optical properties of human enamel and dentine in relationship to structural orientation of enamel prisms and dentinal tubules by optical coherence tomography (OCT). Methods: Discs of 300-400 μm thickness including enamel with cross-cut or long-cut prisms and mid-coronal dentine with cross-cut, long-cut or oblique-cut tubules were obtained from 28 non-carious freshly extracted human third molars sectioned at different directions. Each disc was placed over a metal plate and B-scan images were obtained by a swept-source OCT at 1330 nm centre wavelength (Dental SS-OCT Prototype 1, Panasonic Healthcare Co., Ltd, Japan). Refractive index (n) calculated from optical path length and real thickness, and OCT signal slope (OCTSS) in relation to structural orientation were statistically compared among groups (α = 0.05). The discs were sectioned and observed under SEM to confirm prism or tubule orientations. Results: No significant differences were found in n and OCTSS among cross-cut and long-cut enamel groups (p > 0.05). However, in dentine, there was a significant difference in both variables among different regions. In cross-cut tubule orientation, the average n and OCTSS values were significantly lower compared to other two groups (long-cut and oblique-cut) (p < 0.05). There was a significant difference in both variables between enamel and dentine (p < 0.05). Conclusions: Unlike enamel, refractive index and OCT signal patterns in dentine vary according to structural orientation, with dentine tubules playing the role. Attenuation of OCT signal intensity was small in enamel. The findings may contribute to a better understanding of the interactions of light with the dental tissue. Clinical significance: Precise records of refractive indices and OCT signal patterns may be important for clinical diagnosis of caries and measurement of structural depth for operative purposes using this technology. Effects of dentine structural orientation on refractive index and scattering pattern must be considered when observing human teeth by OCT cross-sectional imaging.

KW - Attenuation

KW - Dentine tubule

KW - Enamel prisms

KW - OCT

KW - Refractive index

KW - Tissue characterisation

UR - http://www.scopus.com/inward/record.url?scp=84859608184&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84859608184&partnerID=8YFLogxK

U2 - 10.1016/j.jdent.2012.01.017

DO - 10.1016/j.jdent.2012.01.017

M3 - Article

C2 - 22342164

AN - SCOPUS:84859608184

VL - 40

SP - 387

EP - 396

JO - Journal of Dentistry

JF - Journal of Dentistry

SN - 0300-5712

IS - 5

ER -