Effect of lights with various wavelengths on bleaching by 30% hydrogen peroxide

Minh Nguyet Luong, Masayuki Otsuki, Yasushi Shimada, Thwe Zin Ei, Yasunori Sumi, Junji Tagami

Research output: Contribution to journalArticle

Abstract

The objective of this study was to evaluate the bleaching effect of light sources with various wavelengths using 30% hydrogen peroxide (HP) in vitro. The hematoporphyrin-stained paper was bleached with HP and irradiated for 10 min using LED light sources with 265, 310, 365, 405, or 450 nm respectively. In control group, HP was applied for 10 min without light irradiation. The bleaching procedure was repeated two times. The L*a*b* values of the samples before bleaching and after each bleaching step were measured using a colorimeter. Color changes of specimens were then calculated and statistically analyzed. There was an interaction between light sources and time of irradiation in the color change (p < 0.05). Time and light sources significantly affected ΔE and ΔL (p < 0.05). The light source of 256 nm showed the highest bleaching effect over time followed by that of 310 nm, which were statistically different from other groups (p < 0.001). The 365 nm, 450 nm groups, and control group showed low bleaching effect visually with no significant differences in ΔE and ΔL (p > 0.05). It was concluded that the wavelengths of the light sources affected the bleaching by HP. The 310-nm light can be a potential source for bleaching.

Original languageEnglish
JournalLasers in Medical Science
DOIs
Publication statusAccepted/In press - Jan 1 2018

Fingerprint

Hydrogen Peroxide
Light
Color
Hematoporphyrins
Control Groups

Keywords

  • Bleaching
  • Hydrogen peroxide
  • LED
  • Ultraviolet
  • Wavelength

ASJC Scopus subject areas

  • Surgery
  • Dermatology

Cite this

Effect of lights with various wavelengths on bleaching by 30% hydrogen peroxide. / Luong, Minh Nguyet; Otsuki, Masayuki; Shimada, Yasushi; Ei, Thwe Zin; Sumi, Yasunori; Tagami, Junji.

In: Lasers in Medical Science, 01.01.2018.

Research output: Contribution to journalArticle

Luong, Minh Nguyet ; Otsuki, Masayuki ; Shimada, Yasushi ; Ei, Thwe Zin ; Sumi, Yasunori ; Tagami, Junji. / Effect of lights with various wavelengths on bleaching by 30% hydrogen peroxide. In: Lasers in Medical Science. 2018.
@article{658d63b74bb44c7b8e6191886a0520c6,
title = "Effect of lights with various wavelengths on bleaching by 30{\%} hydrogen peroxide",
abstract = "The objective of this study was to evaluate the bleaching effect of light sources with various wavelengths using 30{\%} hydrogen peroxide (HP) in vitro. The hematoporphyrin-stained paper was bleached with HP and irradiated for 10 min using LED light sources with 265, 310, 365, 405, or 450 nm respectively. In control group, HP was applied for 10 min without light irradiation. The bleaching procedure was repeated two times. The L*a*b* values of the samples before bleaching and after each bleaching step were measured using a colorimeter. Color changes of specimens were then calculated and statistically analyzed. There was an interaction between light sources and time of irradiation in the color change (p < 0.05). Time and light sources significantly affected ΔE and ΔL (p < 0.05). The light source of 256 nm showed the highest bleaching effect over time followed by that of 310 nm, which were statistically different from other groups (p < 0.001). The 365 nm, 450 nm groups, and control group showed low bleaching effect visually with no significant differences in ΔE and ΔL (p > 0.05). It was concluded that the wavelengths of the light sources affected the bleaching by HP. The 310-nm light can be a potential source for bleaching.",
keywords = "Bleaching, Hydrogen peroxide, LED, Ultraviolet, Wavelength",
author = "Luong, {Minh Nguyet} and Masayuki Otsuki and Yasushi Shimada and Ei, {Thwe Zin} and Yasunori Sumi and Junji Tagami",
year = "2018",
month = "1",
day = "1",
doi = "10.1007/s10103-018-2670-y",
language = "English",
journal = "Lasers in Medical Science",
issn = "0268-8921",
publisher = "Springer London",

}

TY - JOUR

T1 - Effect of lights with various wavelengths on bleaching by 30% hydrogen peroxide

AU - Luong, Minh Nguyet

AU - Otsuki, Masayuki

AU - Shimada, Yasushi

AU - Ei, Thwe Zin

AU - Sumi, Yasunori

AU - Tagami, Junji

PY - 2018/1/1

Y1 - 2018/1/1

N2 - The objective of this study was to evaluate the bleaching effect of light sources with various wavelengths using 30% hydrogen peroxide (HP) in vitro. The hematoporphyrin-stained paper was bleached with HP and irradiated for 10 min using LED light sources with 265, 310, 365, 405, or 450 nm respectively. In control group, HP was applied for 10 min without light irradiation. The bleaching procedure was repeated two times. The L*a*b* values of the samples before bleaching and after each bleaching step were measured using a colorimeter. Color changes of specimens were then calculated and statistically analyzed. There was an interaction between light sources and time of irradiation in the color change (p < 0.05). Time and light sources significantly affected ΔE and ΔL (p < 0.05). The light source of 256 nm showed the highest bleaching effect over time followed by that of 310 nm, which were statistically different from other groups (p < 0.001). The 365 nm, 450 nm groups, and control group showed low bleaching effect visually with no significant differences in ΔE and ΔL (p > 0.05). It was concluded that the wavelengths of the light sources affected the bleaching by HP. The 310-nm light can be a potential source for bleaching.

AB - The objective of this study was to evaluate the bleaching effect of light sources with various wavelengths using 30% hydrogen peroxide (HP) in vitro. The hematoporphyrin-stained paper was bleached with HP and irradiated for 10 min using LED light sources with 265, 310, 365, 405, or 450 nm respectively. In control group, HP was applied for 10 min without light irradiation. The bleaching procedure was repeated two times. The L*a*b* values of the samples before bleaching and after each bleaching step were measured using a colorimeter. Color changes of specimens were then calculated and statistically analyzed. There was an interaction between light sources and time of irradiation in the color change (p < 0.05). Time and light sources significantly affected ΔE and ΔL (p < 0.05). The light source of 256 nm showed the highest bleaching effect over time followed by that of 310 nm, which were statistically different from other groups (p < 0.001). The 365 nm, 450 nm groups, and control group showed low bleaching effect visually with no significant differences in ΔE and ΔL (p > 0.05). It was concluded that the wavelengths of the light sources affected the bleaching by HP. The 310-nm light can be a potential source for bleaching.

KW - Bleaching

KW - Hydrogen peroxide

KW - LED

KW - Ultraviolet

KW - Wavelength

UR - http://www.scopus.com/inward/record.url?scp=85056448879&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85056448879&partnerID=8YFLogxK

U2 - 10.1007/s10103-018-2670-y

DO - 10.1007/s10103-018-2670-y

M3 - Article

C2 - 30421363

AN - SCOPUS:85056448879

JO - Lasers in Medical Science

JF - Lasers in Medical Science

SN - 0268-8921

ER -