Abstract

Purpose To develop and validate the functionality of a novel wide-view visual presentation system with a horizontal and vertical eccentricity angle of 60° for retinotopic mapping by functional MRI (fMRI). Materials and Methods The wide-view presentation system consisted of a 52-mm diameter optical fiber, an entrance apparatus and a presentation apparatus. The terminal edge of the optical fiber at the entrance is flat, while the terminal edge on the presentation apparatus is a sphere of 60 mm in diameter. The subjects wore contact lenses with +20, +22, or +25 magnification to focus on the stimulus, and the visual field eccentricity angle could reach 60°. The signal to noise ratio valuation experiment was performed to evaluate the clarity and quality of the MRI picture image. Checkerboard and random dot stimuli were used to prove that this system could be applied to retinotopic mapping by fMRI. Results The results of the experiment demonstrated that the system is safe in the MRI environment with minimal distortion and can be used for visual retinotopic mapping studies. Wide-field mapping areas (V6, MST) were found in the human visual cortex. Compared with previous studies, the V1 and MT+ surface area approaches but does not fully cover the anatomical area. Nonetheless, the area achieved using the new system is larger than those achievable in previous fMRI studies. Conclusion We developed a versatile, low-cost system for presenting wide-view visual stimuli in the MRI environment. The fMRI retinotopic mapping results proved the viability of this system.

Original languageEnglish
Pages (from-to)441-447
Number of pages7
JournalJournal of Magnetic Resonance Imaging
Volume33
Issue number2
DOIs
Publication statusPublished - Feb 2011

Fingerprint

Magnetic Resonance Imaging
Optical Fibers
Contact Lenses
Signal-To-Noise Ratio
Visual Cortex
Visual Fields
Costs and Cost Analysis

Keywords

  • fMRI
  • retinotopic mapping
  • wide-view visual presentation

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Development of a wide-view visual presentation system for visual retinotopic mapping during functional MRI. / Yan, Tianyi; Jin, Fengzhe; He, Jiping; Wu, Jinglong.

In: Journal of Magnetic Resonance Imaging, Vol. 33, No. 2, 02.2011, p. 441-447.

Research output: Contribution to journalArticle

@article{fe027feb6fc84c0aa1408ca6f71e94af,
title = "Development of a wide-view visual presentation system for visual retinotopic mapping during functional MRI",
abstract = "Purpose To develop and validate the functionality of a novel wide-view visual presentation system with a horizontal and vertical eccentricity angle of 60° for retinotopic mapping by functional MRI (fMRI). Materials and Methods The wide-view presentation system consisted of a 52-mm diameter optical fiber, an entrance apparatus and a presentation apparatus. The terminal edge of the optical fiber at the entrance is flat, while the terminal edge on the presentation apparatus is a sphere of 60 mm in diameter. The subjects wore contact lenses with +20, +22, or +25 magnification to focus on the stimulus, and the visual field eccentricity angle could reach 60°. The signal to noise ratio valuation experiment was performed to evaluate the clarity and quality of the MRI picture image. Checkerboard and random dot stimuli were used to prove that this system could be applied to retinotopic mapping by fMRI. Results The results of the experiment demonstrated that the system is safe in the MRI environment with minimal distortion and can be used for visual retinotopic mapping studies. Wide-field mapping areas (V6, MST) were found in the human visual cortex. Compared with previous studies, the V1 and MT+ surface area approaches but does not fully cover the anatomical area. Nonetheless, the area achieved using the new system is larger than those achievable in previous fMRI studies. Conclusion We developed a versatile, low-cost system for presenting wide-view visual stimuli in the MRI environment. The fMRI retinotopic mapping results proved the viability of this system.",
keywords = "fMRI, retinotopic mapping, wide-view visual presentation",
author = "Tianyi Yan and Fengzhe Jin and Jiping He and Jinglong Wu",
year = "2011",
month = "2",
doi = "10.1002/jmri.22404",
language = "English",
volume = "33",
pages = "441--447",
journal = "Journal of Magnetic Resonance Imaging",
issn = "1053-1807",
publisher = "John Wiley and Sons Inc.",
number = "2",

}

TY - JOUR

T1 - Development of a wide-view visual presentation system for visual retinotopic mapping during functional MRI

AU - Yan, Tianyi

AU - Jin, Fengzhe

AU - He, Jiping

AU - Wu, Jinglong

PY - 2011/2

Y1 - 2011/2

N2 - Purpose To develop and validate the functionality of a novel wide-view visual presentation system with a horizontal and vertical eccentricity angle of 60° for retinotopic mapping by functional MRI (fMRI). Materials and Methods The wide-view presentation system consisted of a 52-mm diameter optical fiber, an entrance apparatus and a presentation apparatus. The terminal edge of the optical fiber at the entrance is flat, while the terminal edge on the presentation apparatus is a sphere of 60 mm in diameter. The subjects wore contact lenses with +20, +22, or +25 magnification to focus on the stimulus, and the visual field eccentricity angle could reach 60°. The signal to noise ratio valuation experiment was performed to evaluate the clarity and quality of the MRI picture image. Checkerboard and random dot stimuli were used to prove that this system could be applied to retinotopic mapping by fMRI. Results The results of the experiment demonstrated that the system is safe in the MRI environment with minimal distortion and can be used for visual retinotopic mapping studies. Wide-field mapping areas (V6, MST) were found in the human visual cortex. Compared with previous studies, the V1 and MT+ surface area approaches but does not fully cover the anatomical area. Nonetheless, the area achieved using the new system is larger than those achievable in previous fMRI studies. Conclusion We developed a versatile, low-cost system for presenting wide-view visual stimuli in the MRI environment. The fMRI retinotopic mapping results proved the viability of this system.

AB - Purpose To develop and validate the functionality of a novel wide-view visual presentation system with a horizontal and vertical eccentricity angle of 60° for retinotopic mapping by functional MRI (fMRI). Materials and Methods The wide-view presentation system consisted of a 52-mm diameter optical fiber, an entrance apparatus and a presentation apparatus. The terminal edge of the optical fiber at the entrance is flat, while the terminal edge on the presentation apparatus is a sphere of 60 mm in diameter. The subjects wore contact lenses with +20, +22, or +25 magnification to focus on the stimulus, and the visual field eccentricity angle could reach 60°. The signal to noise ratio valuation experiment was performed to evaluate the clarity and quality of the MRI picture image. Checkerboard and random dot stimuli were used to prove that this system could be applied to retinotopic mapping by fMRI. Results The results of the experiment demonstrated that the system is safe in the MRI environment with minimal distortion and can be used for visual retinotopic mapping studies. Wide-field mapping areas (V6, MST) were found in the human visual cortex. Compared with previous studies, the V1 and MT+ surface area approaches but does not fully cover the anatomical area. Nonetheless, the area achieved using the new system is larger than those achievable in previous fMRI studies. Conclusion We developed a versatile, low-cost system for presenting wide-view visual stimuli in the MRI environment. The fMRI retinotopic mapping results proved the viability of this system.

KW - fMRI

KW - retinotopic mapping

KW - wide-view visual presentation

UR - http://www.scopus.com/inward/record.url?scp=79551518920&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79551518920&partnerID=8YFLogxK

U2 - 10.1002/jmri.22404

DO - 10.1002/jmri.22404

M3 - Article

C2 - 21274987

AN - SCOPUS:79551518920

VL - 33

SP - 441

EP - 447

JO - Journal of Magnetic Resonance Imaging

JF - Journal of Magnetic Resonance Imaging

SN - 1053-1807

IS - 2

ER -