Development of a new device control system for β-NMR experiments

N. Yoshida, H. Ueno, Akihiro Yoshimi, Y. Ishibashi, Y. Ichikawa, Y. Abe, K. Asahi, M. Chikamori, T. Fujita, T. Furukawa, E. Hikota, D. Nagae, Y. Ohtomo, Y. Saito, H. Shirai, T. Suzuki, X. F. Yang

Research output: Contribution to journalArticle

Abstract

We have developed a device-control system of a β-NMR apparatus for the measurement of nuclear electromagnetic nuclear moments of rare isotopes. In this development, we installed fast relay switches into a high-power tank circuit in order to apply a strong oscillating magnetic field and to sweep its frequency as wide as possible. The system enables to conduct NMR frequency scans with wide frequency windows by dynamically changing the tank-circuit resonant frequency. Furthermore, logical electric-circuit modules of the data taking system were replaced by a programmable logic module. The system performance was evaluated in the β-NMR experiments conducted at the RIBF facility using 20F and 33Cl radioactive isotopes.

Original languageEnglish
Pages (from-to)705-709
Number of pages5
JournalNuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms
Volume317
Issue numberPART B
DOIs
Publication statusPublished - Dec 15 2013

Fingerprint

Nuclear magnetic resonance
Control systems
nuclear magnetic resonance
Networks (circuits)
modules
sweep frequency
data systems
Experiments
relay
Radioisotopes
radioactive isotopes
Isotopes
logic
resonant frequencies
Natural frequencies
switches
isotopes
Switches
Magnetic fields
electromagnetism

Keywords

  • β-NMR
  • Adiabatic fast passage method
  • Electromagnetic moments
  • High-power radio-frequency oscillating field

ASJC Scopus subject areas

  • Instrumentation
  • Nuclear and High Energy Physics

Cite this

Development of a new device control system for β-NMR experiments. / Yoshida, N.; Ueno, H.; Yoshimi, Akihiro; Ishibashi, Y.; Ichikawa, Y.; Abe, Y.; Asahi, K.; Chikamori, M.; Fujita, T.; Furukawa, T.; Hikota, E.; Nagae, D.; Ohtomo, Y.; Saito, Y.; Shirai, H.; Suzuki, T.; Yang, X. F.

In: Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, Vol. 317, No. PART B, 15.12.2013, p. 705-709.

Research output: Contribution to journalArticle

Yoshida, N, Ueno, H, Yoshimi, A, Ishibashi, Y, Ichikawa, Y, Abe, Y, Asahi, K, Chikamori, M, Fujita, T, Furukawa, T, Hikota, E, Nagae, D, Ohtomo, Y, Saito, Y, Shirai, H, Suzuki, T & Yang, XF 2013, 'Development of a new device control system for β-NMR experiments', Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, vol. 317, no. PART B, pp. 705-709. https://doi.org/10.1016/j.nimb.2013.08.057
Yoshida, N. ; Ueno, H. ; Yoshimi, Akihiro ; Ishibashi, Y. ; Ichikawa, Y. ; Abe, Y. ; Asahi, K. ; Chikamori, M. ; Fujita, T. ; Furukawa, T. ; Hikota, E. ; Nagae, D. ; Ohtomo, Y. ; Saito, Y. ; Shirai, H. ; Suzuki, T. ; Yang, X. F. / Development of a new device control system for β-NMR experiments. In: Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms. 2013 ; Vol. 317, No. PART B. pp. 705-709.
@article{0c631dce61b64a3d8b15507f3821e9f2,
title = "Development of a new device control system for β-NMR experiments",
abstract = "We have developed a device-control system of a β-NMR apparatus for the measurement of nuclear electromagnetic nuclear moments of rare isotopes. In this development, we installed fast relay switches into a high-power tank circuit in order to apply a strong oscillating magnetic field and to sweep its frequency as wide as possible. The system enables to conduct NMR frequency scans with wide frequency windows by dynamically changing the tank-circuit resonant frequency. Furthermore, logical electric-circuit modules of the data taking system were replaced by a programmable logic module. The system performance was evaluated in the β-NMR experiments conducted at the RIBF facility using 20F and 33Cl radioactive isotopes.",
keywords = "β-NMR, Adiabatic fast passage method, Electromagnetic moments, High-power radio-frequency oscillating field",
author = "N. Yoshida and H. Ueno and Akihiro Yoshimi and Y. Ishibashi and Y. Ichikawa and Y. Abe and K. Asahi and M. Chikamori and T. Fujita and T. Furukawa and E. Hikota and D. Nagae and Y. Ohtomo and Y. Saito and H. Shirai and T. Suzuki and Yang, {X. F.}",
year = "2013",
month = "12",
day = "15",
doi = "10.1016/j.nimb.2013.08.057",
language = "English",
volume = "317",
pages = "705--709",
journal = "Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms",
issn = "0168-583X",
publisher = "Elsevier",
number = "PART B",

}

TY - JOUR

T1 - Development of a new device control system for β-NMR experiments

AU - Yoshida, N.

AU - Ueno, H.

AU - Yoshimi, Akihiro

AU - Ishibashi, Y.

AU - Ichikawa, Y.

AU - Abe, Y.

AU - Asahi, K.

AU - Chikamori, M.

AU - Fujita, T.

AU - Furukawa, T.

AU - Hikota, E.

AU - Nagae, D.

AU - Ohtomo, Y.

AU - Saito, Y.

AU - Shirai, H.

AU - Suzuki, T.

AU - Yang, X. F.

PY - 2013/12/15

Y1 - 2013/12/15

N2 - We have developed a device-control system of a β-NMR apparatus for the measurement of nuclear electromagnetic nuclear moments of rare isotopes. In this development, we installed fast relay switches into a high-power tank circuit in order to apply a strong oscillating magnetic field and to sweep its frequency as wide as possible. The system enables to conduct NMR frequency scans with wide frequency windows by dynamically changing the tank-circuit resonant frequency. Furthermore, logical electric-circuit modules of the data taking system were replaced by a programmable logic module. The system performance was evaluated in the β-NMR experiments conducted at the RIBF facility using 20F and 33Cl radioactive isotopes.

AB - We have developed a device-control system of a β-NMR apparatus for the measurement of nuclear electromagnetic nuclear moments of rare isotopes. In this development, we installed fast relay switches into a high-power tank circuit in order to apply a strong oscillating magnetic field and to sweep its frequency as wide as possible. The system enables to conduct NMR frequency scans with wide frequency windows by dynamically changing the tank-circuit resonant frequency. Furthermore, logical electric-circuit modules of the data taking system were replaced by a programmable logic module. The system performance was evaluated in the β-NMR experiments conducted at the RIBF facility using 20F and 33Cl radioactive isotopes.

KW - β-NMR

KW - Adiabatic fast passage method

KW - Electromagnetic moments

KW - High-power radio-frequency oscillating field

UR - http://www.scopus.com/inward/record.url?scp=84890122524&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84890122524&partnerID=8YFLogxK

U2 - 10.1016/j.nimb.2013.08.057

DO - 10.1016/j.nimb.2013.08.057

M3 - Article

AN - SCOPUS:84890122524

VL - 317

SP - 705

EP - 709

JO - Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms

JF - Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms

SN - 0168-583X

IS - PART B

ER -