TY - JOUR
T1 - Determination of zirconium, niobium, hafnium and tantalum at ng g -1 levels in geological materials by direct nebulisation of sample HF solution into FI-ICP-MS
AU - Makishima, Akio
AU - Nakamura, Eizo
AU - Nakano, Toshio
PY - 1999/12/1
Y1 - 1999/12/1
N2 - We have developed a rapid and accurate method to determine Zr, Nb, Hf and Ta (denoted as HFSE) in geological samples by inductively coupled plasma-mass spectrometry fitted with a flow injection system (FI-ICP-MS). The method involves sample decomposition by HF followed by HF dissolution of HFSE coprecipitated with insoluble Mg and Ca fluoride residues formed during the initial HF attack. This HF solution was directly nebulized into an ICP mass spectrometer. An external calibration curve method and an isotope dilution method (ID) were applied for the determination of Nb and Ta, and of Zr and Hf, respectively. Recovery yields of HFSE were, 96% for peridotite, basalt and andesite compositions, apart from Zr and Hf for peridotite (> 85%). No matrix effects for either signal intensities of HFSE or isotope ratios of Zr and Hf were observed in basalt, andesite and peridotite solutions down to a dilution factor of 100. Detection limits in silicate rocks were 40, 2, 1 and 0.1 ng g-1 for Zr, Nb, Hf and Ta, respectively. This technique required only 0.1 ml of sample solution, and thus is suitable for analysing small and/or precious samples such as meteorites, mantle peridotites and their mineral separates. We also present newly determined data for the Zr, Nb, Hf and Ta concentrations in USGS silicate reference materials DTS-1, PCC-1, BCR-1, BHVO-1 and AGV-1, GSJ reference materials JB-1, -2, -3, JA-1, -2 and -3, and the Smithsonian reference Allende powder.
AB - We have developed a rapid and accurate method to determine Zr, Nb, Hf and Ta (denoted as HFSE) in geological samples by inductively coupled plasma-mass spectrometry fitted with a flow injection system (FI-ICP-MS). The method involves sample decomposition by HF followed by HF dissolution of HFSE coprecipitated with insoluble Mg and Ca fluoride residues formed during the initial HF attack. This HF solution was directly nebulized into an ICP mass spectrometer. An external calibration curve method and an isotope dilution method (ID) were applied for the determination of Nb and Ta, and of Zr and Hf, respectively. Recovery yields of HFSE were, 96% for peridotite, basalt and andesite compositions, apart from Zr and Hf for peridotite (> 85%). No matrix effects for either signal intensities of HFSE or isotope ratios of Zr and Hf were observed in basalt, andesite and peridotite solutions down to a dilution factor of 100. Detection limits in silicate rocks were 40, 2, 1 and 0.1 ng g-1 for Zr, Nb, Hf and Ta, respectively. This technique required only 0.1 ml of sample solution, and thus is suitable for analysing small and/or precious samples such as meteorites, mantle peridotites and their mineral separates. We also present newly determined data for the Zr, Nb, Hf and Ta concentrations in USGS silicate reference materials DTS-1, PCC-1, BCR-1, BHVO-1 and AGV-1, GSJ reference materials JB-1, -2, -3, JA-1, -2 and -3, and the Smithsonian reference Allende powder.
KW - Flow injection
KW - Geological reference materials
KW - Hf
KW - ICP-MS
KW - Nb
KW - Peridotite
KW - Ta
KW - Zr
UR - http://www.scopus.com/inward/record.url?scp=0002387389&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0002387389&partnerID=8YFLogxK
U2 - 10.1111/j.1751-908X.1999.tb00555.x
DO - 10.1111/j.1751-908X.1999.tb00555.x
M3 - Article
AN - SCOPUS:0002387389
SN - 0150-5505
VL - 23
SP - 7
EP - 20
JO - Geostandards and Geoanalytical Research
JF - Geostandards and Geoanalytical Research
IS - 1
ER -