Detection of normal transitions in a hybrid single-phase Bi2223 high temperature superconducting transformer by using the active power method and a magnetic flux detection coil

Nozomu Nanato, S. Nakamura, S. Tanaka

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

The authors have been developing a hybrid single-phase Bi2223 high temperature superconducting (HTS) transformer used in the AC current source with rated current of over 500A. Its primary coil is a copper coil and secondary coil is a Bi2223 HTS coil. In this paper, the authors propose a new detection method of normal transitions in the secondary coil by using the active power method and a magnetic flux detection coil attached on the inside of the secondary coil. In the proposed method, the normal transitions are detected by measuring active power dissipated in the secondary coil, and induced voltage of the magnetic flux detection coil by a primary and leakage flux of the secondary coil enables to calculate the active power dissipated in only the secondary coil. As experimental results for a hybrid single-phase Bi2223 HTS transformer, it was found that the proposed method enabled to detect the normal transitions in its secondary superconducting coil.

Original languageEnglish
Article number012085
JournalJournal of Physics: Conference Series
Volume871
Issue number1
DOIs
Publication statusPublished - Jul 26 2017

Fingerprint

transformers
magnetic flux
coils
alternating current
leakage
copper

ASJC Scopus subject areas

  • Physics and Astronomy(all)

Cite this

@article{d9520f890aa143e4baae364f4d8293db,
title = "Detection of normal transitions in a hybrid single-phase Bi2223 high temperature superconducting transformer by using the active power method and a magnetic flux detection coil",
abstract = "The authors have been developing a hybrid single-phase Bi2223 high temperature superconducting (HTS) transformer used in the AC current source with rated current of over 500A. Its primary coil is a copper coil and secondary coil is a Bi2223 HTS coil. In this paper, the authors propose a new detection method of normal transitions in the secondary coil by using the active power method and a magnetic flux detection coil attached on the inside of the secondary coil. In the proposed method, the normal transitions are detected by measuring active power dissipated in the secondary coil, and induced voltage of the magnetic flux detection coil by a primary and leakage flux of the secondary coil enables to calculate the active power dissipated in only the secondary coil. As experimental results for a hybrid single-phase Bi2223 HTS transformer, it was found that the proposed method enabled to detect the normal transitions in its secondary superconducting coil.",
author = "Nozomu Nanato and S. Nakamura and S. Tanaka",
year = "2017",
month = "7",
day = "26",
doi = "10.1088/1742-6596/871/1/012085",
language = "English",
volume = "871",
journal = "Journal of Physics: Conference Series",
issn = "1742-6588",
publisher = "IOP Publishing Ltd.",
number = "1",

}

TY - JOUR

T1 - Detection of normal transitions in a hybrid single-phase Bi2223 high temperature superconducting transformer by using the active power method and a magnetic flux detection coil

AU - Nanato, Nozomu

AU - Nakamura, S.

AU - Tanaka, S.

PY - 2017/7/26

Y1 - 2017/7/26

N2 - The authors have been developing a hybrid single-phase Bi2223 high temperature superconducting (HTS) transformer used in the AC current source with rated current of over 500A. Its primary coil is a copper coil and secondary coil is a Bi2223 HTS coil. In this paper, the authors propose a new detection method of normal transitions in the secondary coil by using the active power method and a magnetic flux detection coil attached on the inside of the secondary coil. In the proposed method, the normal transitions are detected by measuring active power dissipated in the secondary coil, and induced voltage of the magnetic flux detection coil by a primary and leakage flux of the secondary coil enables to calculate the active power dissipated in only the secondary coil. As experimental results for a hybrid single-phase Bi2223 HTS transformer, it was found that the proposed method enabled to detect the normal transitions in its secondary superconducting coil.

AB - The authors have been developing a hybrid single-phase Bi2223 high temperature superconducting (HTS) transformer used in the AC current source with rated current of over 500A. Its primary coil is a copper coil and secondary coil is a Bi2223 HTS coil. In this paper, the authors propose a new detection method of normal transitions in the secondary coil by using the active power method and a magnetic flux detection coil attached on the inside of the secondary coil. In the proposed method, the normal transitions are detected by measuring active power dissipated in the secondary coil, and induced voltage of the magnetic flux detection coil by a primary and leakage flux of the secondary coil enables to calculate the active power dissipated in only the secondary coil. As experimental results for a hybrid single-phase Bi2223 HTS transformer, it was found that the proposed method enabled to detect the normal transitions in its secondary superconducting coil.

UR - http://www.scopus.com/inward/record.url?scp=85027993033&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85027993033&partnerID=8YFLogxK

U2 - 10.1088/1742-6596/871/1/012085

DO - 10.1088/1742-6596/871/1/012085

M3 - Article

VL - 871

JO - Journal of Physics: Conference Series

JF - Journal of Physics: Conference Series

SN - 1742-6588

IS - 1

M1 - 012085

ER -