CT fluoroscopy-guided cutting needle biopsy of focal pure ground-glass opacity lung lesions: Diagnostic yield in 83 lesions

Daisaku Inoue, Hideo Gobara, Takao Hiraki, Hidefumi Mimura, Katsuya Kato, Kentaro Shibamoto, Tatsuhiko Iishi, Yusuke Matsui, Shinichi Toyooka, Susumu Kanazawa

Research output: Contribution to journalArticle

22 Citations (Scopus)

Abstract

Objective: The objective of our study was to retrospectively determine the diagnostic yield of CT fluoroscopy-guided cutting needle biopsy of focal pure ground-glass opacity lung lesions. Materials and methods: Biopsies were performed using 20-G coaxial cutting needles for 83 focal pure ground-glass opacity lung lesions (mean lesion size, 12.1 mm). After excluding the lesions for which biopsy specimens were unobtainable and final diagnoses were undetermined, the diagnostic yield, including sensitivity and specificity for a diagnosis of malignancy and accuracy, was calculated. The lesions were then divided into 2 groups: the diagnostic failure group, comprising lesions with false-negative results and for which a biopsy specimen was unobtainable; and the diagnostic success group, comprising lesions with true-negative results and true-positive results. Various variables were compared between the 2 groups by univariate analysis. Results: Biopsy specimens were obtained from 82 lesions, while specimens could not be obtained from 1 lesion. Final diagnosis was undetermined in 16 lesions. The sensitivity and specificity for a diagnosis of malignancy were 95% (58/61) and 100% (5/5), respectively. Diagnostic accuracy was 95% (63/66). The 4 lesions in diagnostic failure group were smaller, deeper, and more likely to be located in the lower lobe and further, for those lesions, number of specimens obtained was smaller, compared with 63 lesions in diagnostic success group. However, none of the differences were statistically significant. Conclusion: CT fluoroscopy-guided cutting needle biopsy provided high diagnostic yield for focal pure ground-glass opacity lung lesions.

Original languageEnglish
Pages (from-to)354-359
Number of pages6
JournalEuropean Journal of Radiology
Volume81
Issue number2
DOIs
Publication statusPublished - Feb 2012

Fingerprint

Fluoroscopy
Needle Biopsy
Glass
Biopsy
Lung
Sensitivity and Specificity
Needles
Neoplasms

Keywords

  • CT
  • Diagnostic yield
  • Ground-glass opacity lesion
  • Lung biopsy
  • Pulmonary neoplasms

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

CT fluoroscopy-guided cutting needle biopsy of focal pure ground-glass opacity lung lesions : Diagnostic yield in 83 lesions. / Inoue, Daisaku; Gobara, Hideo; Hiraki, Takao; Mimura, Hidefumi; Kato, Katsuya; Shibamoto, Kentaro; Iishi, Tatsuhiko; Matsui, Yusuke; Toyooka, Shinichi; Kanazawa, Susumu.

In: European Journal of Radiology, Vol. 81, No. 2, 02.2012, p. 354-359.

Research output: Contribution to journalArticle

@article{7b3c2ce082a2472985104601ec4f63e9,
title = "CT fluoroscopy-guided cutting needle biopsy of focal pure ground-glass opacity lung lesions: Diagnostic yield in 83 lesions",
abstract = "Objective: The objective of our study was to retrospectively determine the diagnostic yield of CT fluoroscopy-guided cutting needle biopsy of focal pure ground-glass opacity lung lesions. Materials and methods: Biopsies were performed using 20-G coaxial cutting needles for 83 focal pure ground-glass opacity lung lesions (mean lesion size, 12.1 mm). After excluding the lesions for which biopsy specimens were unobtainable and final diagnoses were undetermined, the diagnostic yield, including sensitivity and specificity for a diagnosis of malignancy and accuracy, was calculated. The lesions were then divided into 2 groups: the diagnostic failure group, comprising lesions with false-negative results and for which a biopsy specimen was unobtainable; and the diagnostic success group, comprising lesions with true-negative results and true-positive results. Various variables were compared between the 2 groups by univariate analysis. Results: Biopsy specimens were obtained from 82 lesions, while specimens could not be obtained from 1 lesion. Final diagnosis was undetermined in 16 lesions. The sensitivity and specificity for a diagnosis of malignancy were 95{\%} (58/61) and 100{\%} (5/5), respectively. Diagnostic accuracy was 95{\%} (63/66). The 4 lesions in diagnostic failure group were smaller, deeper, and more likely to be located in the lower lobe and further, for those lesions, number of specimens obtained was smaller, compared with 63 lesions in diagnostic success group. However, none of the differences were statistically significant. Conclusion: CT fluoroscopy-guided cutting needle biopsy provided high diagnostic yield for focal pure ground-glass opacity lung lesions.",
keywords = "CT, Diagnostic yield, Ground-glass opacity lesion, Lung biopsy, Pulmonary neoplasms",
author = "Daisaku Inoue and Hideo Gobara and Takao Hiraki and Hidefumi Mimura and Katsuya Kato and Kentaro Shibamoto and Tatsuhiko Iishi and Yusuke Matsui and Shinichi Toyooka and Susumu Kanazawa",
year = "2012",
month = "2",
doi = "10.1016/j.ejrad.2010.11.025",
language = "English",
volume = "81",
pages = "354--359",
journal = "Journal of Medical Imaging",
issn = "0720-048X",
publisher = "Elsevier Ireland Ltd",
number = "2",

}

TY - JOUR

T1 - CT fluoroscopy-guided cutting needle biopsy of focal pure ground-glass opacity lung lesions

T2 - Diagnostic yield in 83 lesions

AU - Inoue, Daisaku

AU - Gobara, Hideo

AU - Hiraki, Takao

AU - Mimura, Hidefumi

AU - Kato, Katsuya

AU - Shibamoto, Kentaro

AU - Iishi, Tatsuhiko

AU - Matsui, Yusuke

AU - Toyooka, Shinichi

AU - Kanazawa, Susumu

PY - 2012/2

Y1 - 2012/2

N2 - Objective: The objective of our study was to retrospectively determine the diagnostic yield of CT fluoroscopy-guided cutting needle biopsy of focal pure ground-glass opacity lung lesions. Materials and methods: Biopsies were performed using 20-G coaxial cutting needles for 83 focal pure ground-glass opacity lung lesions (mean lesion size, 12.1 mm). After excluding the lesions for which biopsy specimens were unobtainable and final diagnoses were undetermined, the diagnostic yield, including sensitivity and specificity for a diagnosis of malignancy and accuracy, was calculated. The lesions were then divided into 2 groups: the diagnostic failure group, comprising lesions with false-negative results and for which a biopsy specimen was unobtainable; and the diagnostic success group, comprising lesions with true-negative results and true-positive results. Various variables were compared between the 2 groups by univariate analysis. Results: Biopsy specimens were obtained from 82 lesions, while specimens could not be obtained from 1 lesion. Final diagnosis was undetermined in 16 lesions. The sensitivity and specificity for a diagnosis of malignancy were 95% (58/61) and 100% (5/5), respectively. Diagnostic accuracy was 95% (63/66). The 4 lesions in diagnostic failure group were smaller, deeper, and more likely to be located in the lower lobe and further, for those lesions, number of specimens obtained was smaller, compared with 63 lesions in diagnostic success group. However, none of the differences were statistically significant. Conclusion: CT fluoroscopy-guided cutting needle biopsy provided high diagnostic yield for focal pure ground-glass opacity lung lesions.

AB - Objective: The objective of our study was to retrospectively determine the diagnostic yield of CT fluoroscopy-guided cutting needle biopsy of focal pure ground-glass opacity lung lesions. Materials and methods: Biopsies were performed using 20-G coaxial cutting needles for 83 focal pure ground-glass opacity lung lesions (mean lesion size, 12.1 mm). After excluding the lesions for which biopsy specimens were unobtainable and final diagnoses were undetermined, the diagnostic yield, including sensitivity and specificity for a diagnosis of malignancy and accuracy, was calculated. The lesions were then divided into 2 groups: the diagnostic failure group, comprising lesions with false-negative results and for which a biopsy specimen was unobtainable; and the diagnostic success group, comprising lesions with true-negative results and true-positive results. Various variables were compared between the 2 groups by univariate analysis. Results: Biopsy specimens were obtained from 82 lesions, while specimens could not be obtained from 1 lesion. Final diagnosis was undetermined in 16 lesions. The sensitivity and specificity for a diagnosis of malignancy were 95% (58/61) and 100% (5/5), respectively. Diagnostic accuracy was 95% (63/66). The 4 lesions in diagnostic failure group were smaller, deeper, and more likely to be located in the lower lobe and further, for those lesions, number of specimens obtained was smaller, compared with 63 lesions in diagnostic success group. However, none of the differences were statistically significant. Conclusion: CT fluoroscopy-guided cutting needle biopsy provided high diagnostic yield for focal pure ground-glass opacity lung lesions.

KW - CT

KW - Diagnostic yield

KW - Ground-glass opacity lesion

KW - Lung biopsy

KW - Pulmonary neoplasms

UR - http://www.scopus.com/inward/record.url?scp=84855567303&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84855567303&partnerID=8YFLogxK

U2 - 10.1016/j.ejrad.2010.11.025

DO - 10.1016/j.ejrad.2010.11.025

M3 - Article

C2 - 21193278

AN - SCOPUS:84855567303

VL - 81

SP - 354

EP - 359

JO - Journal of Medical Imaging

JF - Journal of Medical Imaging

SN - 0720-048X

IS - 2

ER -