Clinical problems in long-duration fetal magnetocardiogram recording

Takayoshi Hosono, Yoshiko Sugita, Akihiko Kandori, Kazuyo Arishiro, Akiko Suetake, Yoshihide Chiba, Hirotsugu Fukuda, Tomoaki Ikeda, Kuniomi Ogata, Tsuyoshi Miyashita, Keiji Tsukada

Research output: Contribution to journalArticle

Abstract

Fetal magnetocardiography (FMCG) was recorded for 20 min to investigate its clinical efficacy. The multichannel SQUID system (MC-6400, Hitachi-Hightechnologies, Japan), which covers a wide area of the torso of pregnant women was used for recording FMCG. We also used simple methods to relieve adverse problems in long-duration measurement for pregnant women in the supine position: (1) light 10-min walking before FMCG measurement to reduce fetal movement, (2) placing a soft cushion under the patient's back to relieve back pains and (3) bending the knees to avoid supine hypotensive syndrome. All these methods were useful in relieving adverse problems.

Original languageEnglish
Pages (from-to)753-756
Number of pages4
JournalInternational Congress Series
Volume1300
DOIs
Publication statusPublished - Jun 2007

Fingerprint

Magnetocardiography
Pregnant Women
Torso
Fetal Movement
Supine Position
Back Pain
Walking
Knee
Japan
Light

Keywords

  • Back pain
  • Fetal magnetocardiography
  • Fetal movement
  • Long-duration recording
  • Supine hypotension syndrome

ASJC Scopus subject areas

  • Medicine(all)

Cite this

Clinical problems in long-duration fetal magnetocardiogram recording. / Hosono, Takayoshi; Sugita, Yoshiko; Kandori, Akihiko; Arishiro, Kazuyo; Suetake, Akiko; Chiba, Yoshihide; Fukuda, Hirotsugu; Ikeda, Tomoaki; Ogata, Kuniomi; Miyashita, Tsuyoshi; Tsukada, Keiji.

In: International Congress Series, Vol. 1300, 06.2007, p. 753-756.

Research output: Contribution to journalArticle

Hosono, T, Sugita, Y, Kandori, A, Arishiro, K, Suetake, A, Chiba, Y, Fukuda, H, Ikeda, T, Ogata, K, Miyashita, T & Tsukada, K 2007, 'Clinical problems in long-duration fetal magnetocardiogram recording', International Congress Series, vol. 1300, pp. 753-756. https://doi.org/10.1016/j.ics.2006.12.078
Hosono T, Sugita Y, Kandori A, Arishiro K, Suetake A, Chiba Y et al. Clinical problems in long-duration fetal magnetocardiogram recording. International Congress Series. 2007 Jun;1300:753-756. https://doi.org/10.1016/j.ics.2006.12.078
Hosono, Takayoshi ; Sugita, Yoshiko ; Kandori, Akihiko ; Arishiro, Kazuyo ; Suetake, Akiko ; Chiba, Yoshihide ; Fukuda, Hirotsugu ; Ikeda, Tomoaki ; Ogata, Kuniomi ; Miyashita, Tsuyoshi ; Tsukada, Keiji. / Clinical problems in long-duration fetal magnetocardiogram recording. In: International Congress Series. 2007 ; Vol. 1300. pp. 753-756.
@article{9a8e82a0e0b04f7aa7cfa56ecabac4ef,
title = "Clinical problems in long-duration fetal magnetocardiogram recording",
abstract = "Fetal magnetocardiography (FMCG) was recorded for 20 min to investigate its clinical efficacy. The multichannel SQUID system (MC-6400, Hitachi-Hightechnologies, Japan), which covers a wide area of the torso of pregnant women was used for recording FMCG. We also used simple methods to relieve adverse problems in long-duration measurement for pregnant women in the supine position: (1) light 10-min walking before FMCG measurement to reduce fetal movement, (2) placing a soft cushion under the patient's back to relieve back pains and (3) bending the knees to avoid supine hypotensive syndrome. All these methods were useful in relieving adverse problems.",
keywords = "Back pain, Fetal magnetocardiography, Fetal movement, Long-duration recording, Supine hypotension syndrome",
author = "Takayoshi Hosono and Yoshiko Sugita and Akihiko Kandori and Kazuyo Arishiro and Akiko Suetake and Yoshihide Chiba and Hirotsugu Fukuda and Tomoaki Ikeda and Kuniomi Ogata and Tsuyoshi Miyashita and Keiji Tsukada",
year = "2007",
month = "6",
doi = "10.1016/j.ics.2006.12.078",
language = "English",
volume = "1300",
pages = "753--756",
journal = "International Congress Series",
issn = "0531-5131",
publisher = "Elsevier BV",

}

TY - JOUR

T1 - Clinical problems in long-duration fetal magnetocardiogram recording

AU - Hosono, Takayoshi

AU - Sugita, Yoshiko

AU - Kandori, Akihiko

AU - Arishiro, Kazuyo

AU - Suetake, Akiko

AU - Chiba, Yoshihide

AU - Fukuda, Hirotsugu

AU - Ikeda, Tomoaki

AU - Ogata, Kuniomi

AU - Miyashita, Tsuyoshi

AU - Tsukada, Keiji

PY - 2007/6

Y1 - 2007/6

N2 - Fetal magnetocardiography (FMCG) was recorded for 20 min to investigate its clinical efficacy. The multichannel SQUID system (MC-6400, Hitachi-Hightechnologies, Japan), which covers a wide area of the torso of pregnant women was used for recording FMCG. We also used simple methods to relieve adverse problems in long-duration measurement for pregnant women in the supine position: (1) light 10-min walking before FMCG measurement to reduce fetal movement, (2) placing a soft cushion under the patient's back to relieve back pains and (3) bending the knees to avoid supine hypotensive syndrome. All these methods were useful in relieving adverse problems.

AB - Fetal magnetocardiography (FMCG) was recorded for 20 min to investigate its clinical efficacy. The multichannel SQUID system (MC-6400, Hitachi-Hightechnologies, Japan), which covers a wide area of the torso of pregnant women was used for recording FMCG. We also used simple methods to relieve adverse problems in long-duration measurement for pregnant women in the supine position: (1) light 10-min walking before FMCG measurement to reduce fetal movement, (2) placing a soft cushion under the patient's back to relieve back pains and (3) bending the knees to avoid supine hypotensive syndrome. All these methods were useful in relieving adverse problems.

KW - Back pain

KW - Fetal magnetocardiography

KW - Fetal movement

KW - Long-duration recording

KW - Supine hypotension syndrome

UR - http://www.scopus.com/inward/record.url?scp=34250000551&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=34250000551&partnerID=8YFLogxK

U2 - 10.1016/j.ics.2006.12.078

DO - 10.1016/j.ics.2006.12.078

M3 - Article

AN - SCOPUS:34250000551

VL - 1300

SP - 753

EP - 756

JO - International Congress Series

JF - International Congress Series

SN - 0531-5131

ER -