Belle-II VXD radiation monitoring and beam abort with sCVD diamond sensors

K. Adamczyk, H. Aihara, C. Angelini, T. Aziz, V. Babu, S. Bacher, S. Bahinipati, E. Barberio, T. Baroncelli, A. K. Basith, G. Batignani, A. Bauer, P. K. Behera, T. Bergauer, S. Bettarini, B. Bhuyan, T. Bilka, F. Bosi, L. Bosisio, A. BozekF. Buchsteiner, G. Casarosa, M. Ceccanti, D. Červenkov, S. R. Chendvankar, N. Dash, S. T. Divekar, Z. Doležal, D. Dutta, F. Forti, M. Friedl, K. Hara, T. Higuchi, T. Horiguchi, C. Irmler, A. Ishikawa, H. B. Jeon, C. Joo, J. Kandra, K. H. Kang, E. Kato, T. Kawasaki, P. Kodyš, T. Kohriki, S. Koike, M. M. Kolwalkar, P. Kvasnička, L. Lanceri, J. Lettenbicher, P. Mammini, S. N. Mayekar, G. B. Mohanty, S. Mohanty, T. Morii, K. R. Nakamura, Z. Natkaniec, K. Negishi, N. K. Nisar, Y. Onuki, W. Ostrowicz, A. Paladino, E. Paoloni, H. Park, F. Pilo, A. Profeti, I. Rashevskaya, K. K. Rao, G. Rizzo, M. Rozanska, S. Sandilya, J. Sasaki, N. Sato, S. Schultschik, C. Schwanda, Y. Seino, N. Shimizu, J. Stypula, S. Tanaka, K. Tanida, G. N. Taylor, R. Thalmeier, R. Thomas, T. Tsuboyama, Satoru Uozumi, P. Urquijo, Lorenzo Vitale, M. Volpi, S. Watanuki, I. J. Watson, J. Webb, J. Wiechczynski, S. Williams, B. Würkner, H. Yamamoto, H. Yin, T. Yoshinobu

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

The Belle-II VerteX Detector (VXD) has been designed to improve the performances with respect to Belle and to cope with an unprecedented luminosity of 8×1035 cm-2 s-1 achievable by the SuperKEKB. Special care is needed to monitor both the radiation dose accumulated throughout the life of the experiment and the instantaneous radiation rate, in order to be able to promptly react to sudden spikes for the purpose of protecting the detectors. A radiation monitoring and beam abort system based on single-crystal diamond sensors is now under an active development for the VXD. The sensors will be placed in several key positions in the vicinity of the interaction region. The severe space limitations require a challenging remote readout of the sensors.

Original languageEnglish
Pages (from-to)480-482
Number of pages3
JournalNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume824
DOIs
Publication statusPublished - Jul 11 2016
Externally publishedYes

Keywords

  • Beam radiation monitoring
  • CVD diamond sensors
  • Diamond radiation detectors
  • Radiation hardness

ASJC Scopus subject areas

  • Instrumentation
  • Nuclear and High Energy Physics

Fingerprint Dive into the research topics of 'Belle-II VXD radiation monitoring and beam abort with sCVD diamond sensors'. Together they form a unique fingerprint.

  • Cite this

    Adamczyk, K., Aihara, H., Angelini, C., Aziz, T., Babu, V., Bacher, S., Bahinipati, S., Barberio, E., Baroncelli, T., Basith, A. K., Batignani, G., Bauer, A., Behera, P. K., Bergauer, T., Bettarini, S., Bhuyan, B., Bilka, T., Bosi, F., Bosisio, L., ... Yoshinobu, T. (2016). Belle-II VXD radiation monitoring and beam abort with sCVD diamond sensors. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 824, 480-482. https://doi.org/10.1016/j.nima.2015.09.007