Assessment of commercial polymers with and without reactive groups using amino acid derivative reactivity assay based on both molar concentration approach and gravimetric approach

Masaharu Fujita, Natsumi Nakashima, Sayaka Wanibuchi, Yusuke Yamamoto, Hajime Kojima, Atsushi Ono, Toshihiko Kasahara

Research output: Contribution to journalArticlepeer-review

Abstract

The amino acid derivative reactivity assay (ADRA), an alternative method for testing skin sensitization, has been established based on the molar concentration approach. However, the additional development of gravimetric concentration and fluorescence detection methods has expanded its range of application to mixtures, which cannot be evaluated using the conventional testing method, the direct peptide reactivity assay (DPRA). Although polymers are generally treated as mixtures, there have been no reports of actual polymer evaluations using alternative methods owing to their insolubility. Therefore, in this study, we evaluated skin sensitization potential of polymers, which is difficult to predict, using ADRA. As polymers have molecular weights ranging from several thousand to more than several tens of thousand Daltons, they are unlikely to cause skin sensitization due to their extremely low penetration into the skin, according to the 500-Da rule. However, if highly reactive functional groups remain at the ends or side chains of polymers, relatively low-molecular-weight polymer components may penetrate the skin to cause sensitization. Polymers can be roughly classified into three major types based on the features of their constituent monomers; we investigated the sensitization capacity of each type of polymer. Polymers with alert sensitization structures at their ends were classified as skin sensitizers, whereas those with no residual reactive groups were classified as nonsensitizers. Although polymers with a glycidyl group need to be evaluated carefully, we concluded that ADRA (0.5 mg/ml) is generally sufficient for polymer hazard assessment.

Original languageEnglish
JournalJournal of Applied Toxicology
DOIs
Publication statusAccepted/In press - 2022

Keywords

  • ADRA
  • amino acid derivative reactivity assay
  • gravimetric approach
  • molar concentration approach
  • polymer

ASJC Scopus subject areas

  • Toxicology

Fingerprint

Dive into the research topics of 'Assessment of commercial polymers with and without reactive groups using amino acid derivative reactivity assay based on both molar concentration approach and gravimetric approach'. Together they form a unique fingerprint.

Cite this