Advanced endocardial mapping systems

Hiroshi Morita, Yasuyuki Kouno, Tohru Ohe

Research output: Contribution to journalArticle

Abstract

The technique of endocardial mapping was developed by the advancement of radiofrequency catheter ablation techniques. Because the catheter ablation has been performed various complex arrhythmias, simple-catheter based mapping methods was limited and multiple electrodes catheter mapping and computed mapping system were developed. The basket catheter has 64-unipolar electrodes and can records endocardial potential during arrhythmia for a moment. The electro-anatomical mapping system, CARTO system, can records entire circuit of arrhythmia and point the critical area, but it will expend more time for mapping and can not indicate for unstable arrhythmias. The new mapping systems, include noncontact mapping system and LocaLisa system, will be able to use in the near future in Japan.

Original languageEnglish
Pages (from-to)1334-1340
Number of pages7
JournalNihon rinsho. Japanese journal of clinical medicine
Volume60
Issue number7
Publication statusPublished - 2002

Fingerprint

Cardiac Arrhythmias
Catheter Ablation
Catheters
Electrodes
Ablation Techniques
Japan

Cite this

Advanced endocardial mapping systems. / Morita, Hiroshi; Kouno, Yasuyuki; Ohe, Tohru.

In: Nihon rinsho. Japanese journal of clinical medicine, Vol. 60, No. 7, 2002, p. 1334-1340.

Research output: Contribution to journalArticle

Morita, Hiroshi ; Kouno, Yasuyuki ; Ohe, Tohru. / Advanced endocardial mapping systems. In: Nihon rinsho. Japanese journal of clinical medicine. 2002 ; Vol. 60, No. 7. pp. 1334-1340.
@article{7d405f1360bd4a66a2db15e338211e0f,
title = "Advanced endocardial mapping systems",
abstract = "The technique of endocardial mapping was developed by the advancement of radiofrequency catheter ablation techniques. Because the catheter ablation has been performed various complex arrhythmias, simple-catheter based mapping methods was limited and multiple electrodes catheter mapping and computed mapping system were developed. The basket catheter has 64-unipolar electrodes and can records endocardial potential during arrhythmia for a moment. The electro-anatomical mapping system, CARTO system, can records entire circuit of arrhythmia and point the critical area, but it will expend more time for mapping and can not indicate for unstable arrhythmias. The new mapping systems, include noncontact mapping system and LocaLisa system, will be able to use in the near future in Japan.",
author = "Hiroshi Morita and Yasuyuki Kouno and Tohru Ohe",
year = "2002",
language = "English",
volume = "60",
pages = "1334--1340",
journal = "Nippon rinsho. Japanese journal of clinical medicine",
issn = "0047-1852",
publisher = "Nipponrinsho Co., Inc.",
number = "7",

}

TY - JOUR

T1 - Advanced endocardial mapping systems

AU - Morita, Hiroshi

AU - Kouno, Yasuyuki

AU - Ohe, Tohru

PY - 2002

Y1 - 2002

N2 - The technique of endocardial mapping was developed by the advancement of radiofrequency catheter ablation techniques. Because the catheter ablation has been performed various complex arrhythmias, simple-catheter based mapping methods was limited and multiple electrodes catheter mapping and computed mapping system were developed. The basket catheter has 64-unipolar electrodes and can records endocardial potential during arrhythmia for a moment. The electro-anatomical mapping system, CARTO system, can records entire circuit of arrhythmia and point the critical area, but it will expend more time for mapping and can not indicate for unstable arrhythmias. The new mapping systems, include noncontact mapping system and LocaLisa system, will be able to use in the near future in Japan.

AB - The technique of endocardial mapping was developed by the advancement of radiofrequency catheter ablation techniques. Because the catheter ablation has been performed various complex arrhythmias, simple-catheter based mapping methods was limited and multiple electrodes catheter mapping and computed mapping system were developed. The basket catheter has 64-unipolar electrodes and can records endocardial potential during arrhythmia for a moment. The electro-anatomical mapping system, CARTO system, can records entire circuit of arrhythmia and point the critical area, but it will expend more time for mapping and can not indicate for unstable arrhythmias. The new mapping systems, include noncontact mapping system and LocaLisa system, will be able to use in the near future in Japan.

UR - http://www.scopus.com/inward/record.url?scp=0036636141&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0036636141&partnerID=8YFLogxK

M3 - Article

C2 - 12136611

AN - SCOPUS:0036636141

VL - 60

SP - 1334

EP - 1340

JO - Nippon rinsho. Japanese journal of clinical medicine

JF - Nippon rinsho. Japanese journal of clinical medicine

SN - 0047-1852

IS - 7