T1 - Accuracy of absorbed dose calculation and measurement of scatter factors with different depth of mini-phantoms using a pinpoint ionization chamber
AU - Oita, Masataka
AU - Watanabe, Yoshiharu
AU - Fujita, Katsuhisa
AU - Furuya, Teruo
AU - Nankumo, Junya
AU - Oda, Makoto
N1 - Copyright:
This record is sourced from MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine
PY - 2004/11
Y1 - 2004/11
N2 - The output factor of high-energy X-ray machines varies with collimation. According to Khan's theory, collimator and phantom scatter factors contribute to total scatter factor. For precise X-ray irradiation, the two factors need to be taken into consideration. To obtain proper factors, we made two original polystyrene cylindrical mini-phantoms. These phantoms are both 4 cm in diameter and have a pinpoint ion chamber placed at a depth of 5 cm and 10 cm, respectively. Using a 6 MV X-ray machine, collimator scatter factors were calculated for various field arrangements (i.e., field sizes ranging from 4 cm x 4 cm to 40 cm x 40 cm at isocenter). To determine if calculated values were appropriate, we measured point doses of 20 X-ray irradiation patterns using a Farmer-type ion chamber with a water equivalent phantom at depths of 5 cm and 10 cm, respectively. Two hundred MUs were irradiated to the above-mentioned depths for each field. Based on the measured doses, variations were obtained for four calculation methods. Accounting for 1) secondary collimator (jaw) setting, 2) blocked field (multi-leaf collimator) setting, 3) Khan's theory using a 5 cm mini-phantom, and 4) Khan's theory using a 10 cm mini-phantom. Dose variations in each method of calculation were as follows: 1) +0.3 to +10.2% (mean, +2.0 to +3.2%) , 2) -2.3 to 0.0% (mean, -0.8 to -0.6%), 3) 0.0 to +1.5% (mean, +0.1 to +0.3%), 4) 0.0 to +1.4% (mean, -0.1 to +0.1%).
AB - The output factor of high-energy X-ray machines varies with collimation. According to Khan's theory, collimator and phantom scatter factors contribute to total scatter factor. For precise X-ray irradiation, the two factors need to be taken into consideration. To obtain proper factors, we made two original polystyrene cylindrical mini-phantoms. These phantoms are both 4 cm in diameter and have a pinpoint ion chamber placed at a depth of 5 cm and 10 cm, respectively. Using a 6 MV X-ray machine, collimator scatter factors were calculated for various field arrangements (i.e., field sizes ranging from 4 cm x 4 cm to 40 cm x 40 cm at isocenter). To determine if calculated values were appropriate, we measured point doses of 20 X-ray irradiation patterns using a Farmer-type ion chamber with a water equivalent phantom at depths of 5 cm and 10 cm, respectively. Two hundred MUs were irradiated to the above-mentioned depths for each field. Based on the measured doses, variations were obtained for four calculation methods. Accounting for 1) secondary collimator (jaw) setting, 2) blocked field (multi-leaf collimator) setting, 3) Khan's theory using a 5 cm mini-phantom, and 4) Khan's theory using a 10 cm mini-phantom. Dose variations in each method of calculation were as follows: 1) +0.3 to +10.2% (mean, +2.0 to +3.2%) , 2) -2.3 to 0.0% (mean, -0.8 to -0.6%), 3) 0.0 to +1.5% (mean, +0.1 to +0.3%), 4) 0.0 to +1.4% (mean, -0.1 to +0.1%).
UR - http://www.scopus.com/inward/record.url?scp=16644362187&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=16644362187&partnerID=8YFLogxK
U2 - 10.6009/jjrt.KJ00003326585
DO - 10.6009/jjrt.KJ00003326585
M3 - Article
C2 - 15568013
AN - SCOPUS:16644362187
VL - 60
SP - 1604
EP - 1610
JO - Nippon Hoshasen Gijutsu Gakkai zasshi
JF - Nippon Hoshasen Gijutsu Gakkai zasshi
SN - 0369-4305
IS - 11
ER -