AC magnetic field imaging by using digital micro-mirror device

Research output: Chapter in Book/Report/Conference proceedingConference contribution

2 Citations (Scopus)

Abstract

We demonstrated optical imagings of AC magnetic fields. A digital micro-mirror device and a lock-in detection allowed obtaining sub-millimeter resolution images without using magnetic shields. Images of gradient field from a wire suggested its potential to apply for signal-source estimations.

Original languageEnglish
Title of host publication22nd Microoptics Conference, MOC 2017
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages212-213
Number of pages2
Volume2017-November
ISBN (Electronic)9784863486096
DOIs
Publication statusPublished - Jan 2 2018
Event22nd Microoptics Conference, MOC 2017 - Tokyo, Japan
Duration: Nov 19 2017Nov 22 2017

Other

Other22nd Microoptics Conference, MOC 2017
CountryJapan
CityTokyo
Period11/19/1711/22/17

Fingerprint

image resolution
Image resolution
alternating current
Mirrors
wire
Wire
Magnetic fields
mirrors
Imaging techniques
gradients
magnetic fields

ASJC Scopus subject areas

  • Atomic and Molecular Physics, and Optics
  • Electronic, Optical and Magnetic Materials

Cite this

Taue, S., Toyota, Y., Fujimori, K., & Fukano, H. (2018). AC magnetic field imaging by using digital micro-mirror device. In 22nd Microoptics Conference, MOC 2017 (Vol. 2017-November, pp. 212-213). Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.23919/MOC.2017.8244562

AC magnetic field imaging by using digital micro-mirror device. / Taue, Shuji; Toyota, Yoshitaka; Fujimori, Kazuhiro; Fukano, Hideki.

22nd Microoptics Conference, MOC 2017. Vol. 2017-November Institute of Electrical and Electronics Engineers Inc., 2018. p. 212-213.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Taue, S, Toyota, Y, Fujimori, K & Fukano, H 2018, AC magnetic field imaging by using digital micro-mirror device. in 22nd Microoptics Conference, MOC 2017. vol. 2017-November, Institute of Electrical and Electronics Engineers Inc., pp. 212-213, 22nd Microoptics Conference, MOC 2017, Tokyo, Japan, 11/19/17. https://doi.org/10.23919/MOC.2017.8244562
Taue S, Toyota Y, Fujimori K, Fukano H. AC magnetic field imaging by using digital micro-mirror device. In 22nd Microoptics Conference, MOC 2017. Vol. 2017-November. Institute of Electrical and Electronics Engineers Inc. 2018. p. 212-213 https://doi.org/10.23919/MOC.2017.8244562
Taue, Shuji ; Toyota, Yoshitaka ; Fujimori, Kazuhiro ; Fukano, Hideki. / AC magnetic field imaging by using digital micro-mirror device. 22nd Microoptics Conference, MOC 2017. Vol. 2017-November Institute of Electrical and Electronics Engineers Inc., 2018. pp. 212-213
@inproceedings{dddf9040da3c49deb5113ae30ba83f63,
title = "AC magnetic field imaging by using digital micro-mirror device",
abstract = "We demonstrated optical imagings of AC magnetic fields. A digital micro-mirror device and a lock-in detection allowed obtaining sub-millimeter resolution images without using magnetic shields. Images of gradient field from a wire suggested its potential to apply for signal-source estimations.",
author = "Shuji Taue and Yoshitaka Toyota and Kazuhiro Fujimori and Hideki Fukano",
year = "2018",
month = "1",
day = "2",
doi = "10.23919/MOC.2017.8244562",
language = "English",
volume = "2017-November",
pages = "212--213",
booktitle = "22nd Microoptics Conference, MOC 2017",
publisher = "Institute of Electrical and Electronics Engineers Inc.",

}

TY - GEN

T1 - AC magnetic field imaging by using digital micro-mirror device

AU - Taue, Shuji

AU - Toyota, Yoshitaka

AU - Fujimori, Kazuhiro

AU - Fukano, Hideki

PY - 2018/1/2

Y1 - 2018/1/2

N2 - We demonstrated optical imagings of AC magnetic fields. A digital micro-mirror device and a lock-in detection allowed obtaining sub-millimeter resolution images without using magnetic shields. Images of gradient field from a wire suggested its potential to apply for signal-source estimations.

AB - We demonstrated optical imagings of AC magnetic fields. A digital micro-mirror device and a lock-in detection allowed obtaining sub-millimeter resolution images without using magnetic shields. Images of gradient field from a wire suggested its potential to apply for signal-source estimations.

UR - http://www.scopus.com/inward/record.url?scp=85045931127&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85045931127&partnerID=8YFLogxK

U2 - 10.23919/MOC.2017.8244562

DO - 10.23919/MOC.2017.8244562

M3 - Conference contribution

AN - SCOPUS:85045931127

VL - 2017-November

SP - 212

EP - 213

BT - 22nd Microoptics Conference, MOC 2017

PB - Institute of Electrical and Electronics Engineers Inc.

ER -