T1 - A reinforced sternal wiring technique for transverse thoracosternotomy closure in bilateral lung transplantation
T2 - From biomechanical test to clinical application
AU - Oto, Takahiro
AU - Venkatachalam, Ramkumar
AU - Morsi, Yos S.
AU - Marasco, Silvana
AU - Pick, Adrian
AU - Rabinov, Marc
AU - Rosenfeldt, Franklin
PY - 2007/7
Y1 - 2007/7
N2 - Objectives: A high incidence of failure of transverse thoracosternotomy closure, involving the loops of wire cutting through the sternum, remains a significant morbidity after bilateral lung transplantation. We postulated that placing peristernal wires inside the usual longitudinal wires could prevent the longitudinal wires from cutting through the sternum. The aims of this study were to investigate the biomechanical and clinical efficacy of the proposed reinforced sternal closure technique. Methods: In vitro, 24 artificial sternal models were wired with the reinforced or conventional wiring techniques and were tested either by means of longitudinal distraction or anterior-posterior shear (n = 6 per group). In vivo, the 6-month outcomes of 70 bilateral lung transplantations, including 27 reinforced and 43 conventional wiring techniques, were assessed. Results: Reinforced wiring was stronger than conventional wiring for both longitudinal distraction (yield load: 585 ± 60 vs 334 ± 21 N [P = .03]; maximum load: 807 ± 60 vs 525 ± 34 N [P = .03]; postyield stiffness: 91.0 ± 22.0 vs 32.8 ± 11.8 N/mm [P = .04]) and anterior-posterior shear (yield load: 405 ± 9 vs 364 ± 16 N [P = .03]; postyield stiffness: 47.4 ± 6.1 vs 27.5 ± 5.1 N/mm [P = .04]). In multivariate analysis, the use of the conventional wiring technique (odds ratio, 5.38; P = .04) and osteoporosis (odds ratio, 18.31; P = .0005) were significant risk factors associated with sternal dehiscence. In the patients with osteoporosis (n = 25), the incidence of sternal dehiscence in the reinforced wiring group (4/16 [25%]) was significantly lower than that in the conventional wiring group (7/9 [78%], P = .02). Conclusion: Osteoporosis is a significant risk factor for sternal dehiscence after bilateral lung transplantation. The new reinforced sternal wiring technique provides biomechanically superior fixation of the sternum and clinically reduces the incidence of sternal dehiscence in high-risk osteoporotic patients undergoing bilateral lung transplantation.
AB - Objectives: A high incidence of failure of transverse thoracosternotomy closure, involving the loops of wire cutting through the sternum, remains a significant morbidity after bilateral lung transplantation. We postulated that placing peristernal wires inside the usual longitudinal wires could prevent the longitudinal wires from cutting through the sternum. The aims of this study were to investigate the biomechanical and clinical efficacy of the proposed reinforced sternal closure technique. Methods: In vitro, 24 artificial sternal models were wired with the reinforced or conventional wiring techniques and were tested either by means of longitudinal distraction or anterior-posterior shear (n = 6 per group). In vivo, the 6-month outcomes of 70 bilateral lung transplantations, including 27 reinforced and 43 conventional wiring techniques, were assessed. Results: Reinforced wiring was stronger than conventional wiring for both longitudinal distraction (yield load: 585 ± 60 vs 334 ± 21 N [P = .03]; maximum load: 807 ± 60 vs 525 ± 34 N [P = .03]; postyield stiffness: 91.0 ± 22.0 vs 32.8 ± 11.8 N/mm [P = .04]) and anterior-posterior shear (yield load: 405 ± 9 vs 364 ± 16 N [P = .03]; postyield stiffness: 47.4 ± 6.1 vs 27.5 ± 5.1 N/mm [P = .04]). In multivariate analysis, the use of the conventional wiring technique (odds ratio, 5.38; P = .04) and osteoporosis (odds ratio, 18.31; P = .0005) were significant risk factors associated with sternal dehiscence. In the patients with osteoporosis (n = 25), the incidence of sternal dehiscence in the reinforced wiring group (4/16 [25%]) was significantly lower than that in the conventional wiring group (7/9 [78%], P = .02). Conclusion: Osteoporosis is a significant risk factor for sternal dehiscence after bilateral lung transplantation. The new reinforced sternal wiring technique provides biomechanically superior fixation of the sternum and clinically reduces the incidence of sternal dehiscence in high-risk osteoporotic patients undergoing bilateral lung transplantation.
UR - http://www.scopus.com/inward/record.url?scp=34250711375&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=34250711375&partnerID=8YFLogxK
U2 - 10.1016/j.jtcvs.2007.03.003
DO - 10.1016/j.jtcvs.2007.03.003
M3 - Article
C2 - 17599512
AN - SCOPUS:34250711375
VL - 134
SP - 218
EP - 224
JO - Journal of Thoracic and Cardiovascular Surgery
JF - Journal of Thoracic and Cardiovascular Surgery
SN - 0022-5223
IS - 1
ER -