A nano emulsion generator using a microchannel and a bolt blamped type transducer

Takefumi Kanda, Yusuke Kiyama, Koichi Suzumori

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

The goal of this research is to generate antitumor substance emulsion which has a droplets' diameter of 200 nm or less. In our previous study, a microchannel device was oscillated by 2.3 MHz plate type vibrator. In this study, a small bolt clamped type transducer has been designed and fabricated to apply higher pressure against the micron-size droplets. The cross sectional pattern of the ultrasonic microchannel device and the bolt clamped type transducer was designed by using FEM. By using the device, we have succeeded in generating nano emulsion and the peak of diameter was in 100 nm.

Original languageEnglish
Title of host publicationIEEE International Ultrasonics Symposium, IUS
Pages194-196
Number of pages3
DOIs
Publication statusPublished - 2013
Event2013 IEEE International Ultrasonics Symposium, IUS 2013 - Prague, Czech Republic
Duration: Jul 21 2013Jul 25 2013

Other

Other2013 IEEE International Ultrasonics Symposium, IUS 2013
CountryCzech Republic
CityPrague
Period7/21/137/25/13

Fingerprint

bolts
microchannels
emulsions
transducers
generators
ultrasonics

Keywords

  • Bolt clamped type transducer
  • Microchannel
  • Nano emulsion
  • Piezoelectric vibrator

ASJC Scopus subject areas

  • Acoustics and Ultrasonics

Cite this

Kanda, T., Kiyama, Y., & Suzumori, K. (2013). A nano emulsion generator using a microchannel and a bolt blamped type transducer. In IEEE International Ultrasonics Symposium, IUS (pp. 194-196). [6725077] https://doi.org/10.1109/ULTSYM.2013.0050

A nano emulsion generator using a microchannel and a bolt blamped type transducer. / Kanda, Takefumi; Kiyama, Yusuke; Suzumori, Koichi.

IEEE International Ultrasonics Symposium, IUS. 2013. p. 194-196 6725077.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Kanda, T, Kiyama, Y & Suzumori, K 2013, A nano emulsion generator using a microchannel and a bolt blamped type transducer. in IEEE International Ultrasonics Symposium, IUS., 6725077, pp. 194-196, 2013 IEEE International Ultrasonics Symposium, IUS 2013, Prague, Czech Republic, 7/21/13. https://doi.org/10.1109/ULTSYM.2013.0050
Kanda T, Kiyama Y, Suzumori K. A nano emulsion generator using a microchannel and a bolt blamped type transducer. In IEEE International Ultrasonics Symposium, IUS. 2013. p. 194-196. 6725077 https://doi.org/10.1109/ULTSYM.2013.0050
Kanda, Takefumi ; Kiyama, Yusuke ; Suzumori, Koichi. / A nano emulsion generator using a microchannel and a bolt blamped type transducer. IEEE International Ultrasonics Symposium, IUS. 2013. pp. 194-196
@inproceedings{50732f8c75574d4e8ba6b09b3d1209dd,
title = "A nano emulsion generator using a microchannel and a bolt blamped type transducer",
abstract = "The goal of this research is to generate antitumor substance emulsion which has a droplets' diameter of 200 nm or less. In our previous study, a microchannel device was oscillated by 2.3 MHz plate type vibrator. In this study, a small bolt clamped type transducer has been designed and fabricated to apply higher pressure against the micron-size droplets. The cross sectional pattern of the ultrasonic microchannel device and the bolt clamped type transducer was designed by using FEM. By using the device, we have succeeded in generating nano emulsion and the peak of diameter was in 100 nm.",
keywords = "Bolt clamped type transducer, Microchannel, Nano emulsion, Piezoelectric vibrator",
author = "Takefumi Kanda and Yusuke Kiyama and Koichi Suzumori",
year = "2013",
doi = "10.1109/ULTSYM.2013.0050",
language = "English",
isbn = "9781467356862",
pages = "194--196",
booktitle = "IEEE International Ultrasonics Symposium, IUS",

}

TY - GEN

T1 - A nano emulsion generator using a microchannel and a bolt blamped type transducer

AU - Kanda, Takefumi

AU - Kiyama, Yusuke

AU - Suzumori, Koichi

PY - 2013

Y1 - 2013

N2 - The goal of this research is to generate antitumor substance emulsion which has a droplets' diameter of 200 nm or less. In our previous study, a microchannel device was oscillated by 2.3 MHz plate type vibrator. In this study, a small bolt clamped type transducer has been designed and fabricated to apply higher pressure against the micron-size droplets. The cross sectional pattern of the ultrasonic microchannel device and the bolt clamped type transducer was designed by using FEM. By using the device, we have succeeded in generating nano emulsion and the peak of diameter was in 100 nm.

AB - The goal of this research is to generate antitumor substance emulsion which has a droplets' diameter of 200 nm or less. In our previous study, a microchannel device was oscillated by 2.3 MHz plate type vibrator. In this study, a small bolt clamped type transducer has been designed and fabricated to apply higher pressure against the micron-size droplets. The cross sectional pattern of the ultrasonic microchannel device and the bolt clamped type transducer was designed by using FEM. By using the device, we have succeeded in generating nano emulsion and the peak of diameter was in 100 nm.

KW - Bolt clamped type transducer

KW - Microchannel

KW - Nano emulsion

KW - Piezoelectric vibrator

UR - http://www.scopus.com/inward/record.url?scp=84894309849&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84894309849&partnerID=8YFLogxK

U2 - 10.1109/ULTSYM.2013.0050

DO - 10.1109/ULTSYM.2013.0050

M3 - Conference contribution

SN - 9781467356862

SP - 194

EP - 196

BT - IEEE International Ultrasonics Symposium, IUS

ER -