A high-resolution soft X-ray photoemission apparatus combined with a laser molecular-beam epitaxy system at SPring-8 BL17SU

K. Horiba, Ritsuko Eguchi, N. Kamakura, K. Yamamoto, M. Matsunami, Y. Takata, Y. Senba, H. Ohashi, S. Shin

Research output: Chapter in Book/Report/Conference proceedingConference contribution

4 Citations (Scopus)

Abstract

We have constructed a high-resolution synchrotron-radiation photoemission apparatus combined with a laser molecular-beam epitaxy (laser MBE) system in order to investigate the electronic structure of thin films. The system is installed at the newly-built soft x-ray undulator beamline BL17SU of SPring-8. Single crystal thin films fabricated by laser MBE can be transferred quickly into the photoemission chamber under ultra-high vacuum condition. The photoemission spectrometer is equipped for high-throughput and high energy-resolution angle-resolved photoemission measurements. High energy-resolution and stability of the beamline optics enable us to achieve the best total energy resolution of 51 meV at 867 eV excitation. The performance and characteristics of the system is demonstrated by showing results on LaNiO 3 thin films.

Original languageEnglish
Title of host publicationAIP Conference Proceedings
Pages1611-1614
Number of pages4
Volume879
DOIs
Publication statusPublished - 2007
Externally publishedYes
EventSYNCHROTRON RADIATION INSTRUMENTATION: 9th International Conference on Synchrotron Radiation Instrumentation - Daegu, Korea, Republic of
Duration: May 28 2006Jun 28 2006

Other

OtherSYNCHROTRON RADIATION INSTRUMENTATION: 9th International Conference on Synchrotron Radiation Instrumentation
CountryKorea, Republic of
CityDaegu
Period5/28/066/28/06

Fingerprint

molecular beam epitaxy
photoelectric emission
laser beams
high resolution
x rays
thin films
ultrahigh vacuum
energy
synchrotron radiation
chambers
optics
spectrometers
electronic structure
single crystals
excitation

Keywords

  • Laser molecular beam epitaxy
  • Photoemission spectroscopy

ASJC Scopus subject areas

  • Physics and Astronomy(all)

Cite this

Horiba, K., Eguchi, R., Kamakura, N., Yamamoto, K., Matsunami, M., Takata, Y., ... Shin, S. (2007). A high-resolution soft X-ray photoemission apparatus combined with a laser molecular-beam epitaxy system at SPring-8 BL17SU. In AIP Conference Proceedings (Vol. 879, pp. 1611-1614) https://doi.org/10.1063/1.2436374

A high-resolution soft X-ray photoemission apparatus combined with a laser molecular-beam epitaxy system at SPring-8 BL17SU. / Horiba, K.; Eguchi, Ritsuko; Kamakura, N.; Yamamoto, K.; Matsunami, M.; Takata, Y.; Senba, Y.; Ohashi, H.; Shin, S.

AIP Conference Proceedings. Vol. 879 2007. p. 1611-1614.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Horiba, K, Eguchi, R, Kamakura, N, Yamamoto, K, Matsunami, M, Takata, Y, Senba, Y, Ohashi, H & Shin, S 2007, A high-resolution soft X-ray photoemission apparatus combined with a laser molecular-beam epitaxy system at SPring-8 BL17SU. in AIP Conference Proceedings. vol. 879, pp. 1611-1614, SYNCHROTRON RADIATION INSTRUMENTATION: 9th International Conference on Synchrotron Radiation Instrumentation, Daegu, Korea, Republic of, 5/28/06. https://doi.org/10.1063/1.2436374
Horiba K, Eguchi R, Kamakura N, Yamamoto K, Matsunami M, Takata Y et al. A high-resolution soft X-ray photoemission apparatus combined with a laser molecular-beam epitaxy system at SPring-8 BL17SU. In AIP Conference Proceedings. Vol. 879. 2007. p. 1611-1614 https://doi.org/10.1063/1.2436374
Horiba, K. ; Eguchi, Ritsuko ; Kamakura, N. ; Yamamoto, K. ; Matsunami, M. ; Takata, Y. ; Senba, Y. ; Ohashi, H. ; Shin, S. / A high-resolution soft X-ray photoemission apparatus combined with a laser molecular-beam epitaxy system at SPring-8 BL17SU. AIP Conference Proceedings. Vol. 879 2007. pp. 1611-1614
@inproceedings{2718dd5d959a4bf59b9f4bacfd193641,
title = "A high-resolution soft X-ray photoemission apparatus combined with a laser molecular-beam epitaxy system at SPring-8 BL17SU",
abstract = "We have constructed a high-resolution synchrotron-radiation photoemission apparatus combined with a laser molecular-beam epitaxy (laser MBE) system in order to investigate the electronic structure of thin films. The system is installed at the newly-built soft x-ray undulator beamline BL17SU of SPring-8. Single crystal thin films fabricated by laser MBE can be transferred quickly into the photoemission chamber under ultra-high vacuum condition. The photoemission spectrometer is equipped for high-throughput and high energy-resolution angle-resolved photoemission measurements. High energy-resolution and stability of the beamline optics enable us to achieve the best total energy resolution of 51 meV at 867 eV excitation. The performance and characteristics of the system is demonstrated by showing results on LaNiO 3 thin films.",
keywords = "Laser molecular beam epitaxy, Photoemission spectroscopy",
author = "K. Horiba and Ritsuko Eguchi and N. Kamakura and K. Yamamoto and M. Matsunami and Y. Takata and Y. Senba and H. Ohashi and S. Shin",
year = "2007",
doi = "10.1063/1.2436374",
language = "English",
isbn = "0735403732",
volume = "879",
pages = "1611--1614",
booktitle = "AIP Conference Proceedings",

}

TY - GEN

T1 - A high-resolution soft X-ray photoemission apparatus combined with a laser molecular-beam epitaxy system at SPring-8 BL17SU

AU - Horiba, K.

AU - Eguchi, Ritsuko

AU - Kamakura, N.

AU - Yamamoto, K.

AU - Matsunami, M.

AU - Takata, Y.

AU - Senba, Y.

AU - Ohashi, H.

AU - Shin, S.

PY - 2007

Y1 - 2007

N2 - We have constructed a high-resolution synchrotron-radiation photoemission apparatus combined with a laser molecular-beam epitaxy (laser MBE) system in order to investigate the electronic structure of thin films. The system is installed at the newly-built soft x-ray undulator beamline BL17SU of SPring-8. Single crystal thin films fabricated by laser MBE can be transferred quickly into the photoemission chamber under ultra-high vacuum condition. The photoemission spectrometer is equipped for high-throughput and high energy-resolution angle-resolved photoemission measurements. High energy-resolution and stability of the beamline optics enable us to achieve the best total energy resolution of 51 meV at 867 eV excitation. The performance and characteristics of the system is demonstrated by showing results on LaNiO 3 thin films.

AB - We have constructed a high-resolution synchrotron-radiation photoemission apparatus combined with a laser molecular-beam epitaxy (laser MBE) system in order to investigate the electronic structure of thin films. The system is installed at the newly-built soft x-ray undulator beamline BL17SU of SPring-8. Single crystal thin films fabricated by laser MBE can be transferred quickly into the photoemission chamber under ultra-high vacuum condition. The photoemission spectrometer is equipped for high-throughput and high energy-resolution angle-resolved photoemission measurements. High energy-resolution and stability of the beamline optics enable us to achieve the best total energy resolution of 51 meV at 867 eV excitation. The performance and characteristics of the system is demonstrated by showing results on LaNiO 3 thin films.

KW - Laser molecular beam epitaxy

KW - Photoemission spectroscopy

UR - http://www.scopus.com/inward/record.url?scp=33947424683&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33947424683&partnerID=8YFLogxK

U2 - 10.1063/1.2436374

DO - 10.1063/1.2436374

M3 - Conference contribution

AN - SCOPUS:33947424683

SN - 0735403732

SN - 9780735403734

VL - 879

SP - 1611

EP - 1614

BT - AIP Conference Proceedings

ER -