A colorimetric paper-based analytical device coupled with hollow fiber membrane liquid phase microextraction (HF-LPME) for highly sensitive detection of hexavalent chromium in water samples

Waleed Alahmad, Nuttanee Tungkijanansin, Takashi Kaneta, Pakorn Varanusupakul

Research output: Contribution to journalArticle

11 Citations (Scopus)

Abstract

A simple and highly sensitive procedure based on the combination of hollow fiber membrane liquid phase microextraction and a microfluidic paper-based analytical device (µPAD) was developed for pre-concentration and determination of hexavalent chromium in water samples. The hexavalent chromium was pre-concentrated using the HF-LPME technique via ion exchange or a coupled transport process through a supported ionic liquid (Aliquat 336) prior to colorimetric detection with diphenylcarbazide on the µPAD. The violet colour could be seen by the naked eye. Images from the µPADs were scanned using a commercial desktop scanner at 600 dpi resolution. ImageJ software was used for quantitative analysis by measuring the intensity values at green colour channel since it gave the best sensitivity among the RGB colour. Under optimal conditions, the calibration curve was linear in the range 10–90 µg L-1, with a limit of detection of 3 µg L-1. The developed method was successfully applied to determine the level of hexavalent chromium spiked into natural water samples at the parts-per-billion (ppb) level, and the results were in good agreement with those obtained using inductively coupled plasma atomic emission spectroscopy (ICP-AES). The developed method was able to improve the detection limit of the conventional µPAD, and was expected to be used for the effective analysis of hexavalent chromium in natural water.

Original languageEnglish
Pages (from-to)78-84
Number of pages7
JournalTalanta
Volume190
DOIs
Publication statusPublished - Dec 1 2018

Fingerprint

Liquid Phase Microextraction
Liquid membranes
Equipment and Supplies
Membranes
Water
Fibers
Color
Limit of Detection
Diphenylcarbazide
Atomic emission spectroscopy
Ionic Liquids
Atomic Spectrophotometry
Microfluidics
Ion Exchange
Inductively coupled plasma
Calibration
Ion exchange
Software
chromium hexavalent ion
Chemical analysis

Keywords

  • Colorimetric detection
  • Hexavalent chromium
  • Hollow fiber membrane liquid phase microextraction
  • Microfluidic paper-based analytical devices

ASJC Scopus subject areas

  • Chemistry(all)

Cite this

A colorimetric paper-based analytical device coupled with hollow fiber membrane liquid phase microextraction (HF-LPME) for highly sensitive detection of hexavalent chromium in water samples. / Alahmad, Waleed; Tungkijanansin, Nuttanee; Kaneta, Takashi; Varanusupakul, Pakorn.

In: Talanta, Vol. 190, 01.12.2018, p. 78-84.

Research output: Contribution to journalArticle

@article{2be1cb72d0b845fdb85ba39b56a5695f,
title = "A colorimetric paper-based analytical device coupled with hollow fiber membrane liquid phase microextraction (HF-LPME) for highly sensitive detection of hexavalent chromium in water samples",
abstract = "A simple and highly sensitive procedure based on the combination of hollow fiber membrane liquid phase microextraction and a microfluidic paper-based analytical device (µPAD) was developed for pre-concentration and determination of hexavalent chromium in water samples. The hexavalent chromium was pre-concentrated using the HF-LPME technique via ion exchange or a coupled transport process through a supported ionic liquid (Aliquat 336) prior to colorimetric detection with diphenylcarbazide on the µPAD. The violet colour could be seen by the naked eye. Images from the µPADs were scanned using a commercial desktop scanner at 600 dpi resolution. ImageJ software was used for quantitative analysis by measuring the intensity values at green colour channel since it gave the best sensitivity among the RGB colour. Under optimal conditions, the calibration curve was linear in the range 10–90 µg L-1, with a limit of detection of 3 µg L-1. The developed method was successfully applied to determine the level of hexavalent chromium spiked into natural water samples at the parts-per-billion (ppb) level, and the results were in good agreement with those obtained using inductively coupled plasma atomic emission spectroscopy (ICP-AES). The developed method was able to improve the detection limit of the conventional µPAD, and was expected to be used for the effective analysis of hexavalent chromium in natural water.",
keywords = "Colorimetric detection, Hexavalent chromium, Hollow fiber membrane liquid phase microextraction, Microfluidic paper-based analytical devices",
author = "Waleed Alahmad and Nuttanee Tungkijanansin and Takashi Kaneta and Pakorn Varanusupakul",
year = "2018",
month = "12",
day = "1",
doi = "10.1016/j.talanta.2018.07.056",
language = "English",
volume = "190",
pages = "78--84",
journal = "Talanta",
issn = "0039-9140",
publisher = "Elsevier",

}

TY - JOUR

T1 - A colorimetric paper-based analytical device coupled with hollow fiber membrane liquid phase microextraction (HF-LPME) for highly sensitive detection of hexavalent chromium in water samples

AU - Alahmad, Waleed

AU - Tungkijanansin, Nuttanee

AU - Kaneta, Takashi

AU - Varanusupakul, Pakorn

PY - 2018/12/1

Y1 - 2018/12/1

N2 - A simple and highly sensitive procedure based on the combination of hollow fiber membrane liquid phase microextraction and a microfluidic paper-based analytical device (µPAD) was developed for pre-concentration and determination of hexavalent chromium in water samples. The hexavalent chromium was pre-concentrated using the HF-LPME technique via ion exchange or a coupled transport process through a supported ionic liquid (Aliquat 336) prior to colorimetric detection with diphenylcarbazide on the µPAD. The violet colour could be seen by the naked eye. Images from the µPADs were scanned using a commercial desktop scanner at 600 dpi resolution. ImageJ software was used for quantitative analysis by measuring the intensity values at green colour channel since it gave the best sensitivity among the RGB colour. Under optimal conditions, the calibration curve was linear in the range 10–90 µg L-1, with a limit of detection of 3 µg L-1. The developed method was successfully applied to determine the level of hexavalent chromium spiked into natural water samples at the parts-per-billion (ppb) level, and the results were in good agreement with those obtained using inductively coupled plasma atomic emission spectroscopy (ICP-AES). The developed method was able to improve the detection limit of the conventional µPAD, and was expected to be used for the effective analysis of hexavalent chromium in natural water.

AB - A simple and highly sensitive procedure based on the combination of hollow fiber membrane liquid phase microextraction and a microfluidic paper-based analytical device (µPAD) was developed for pre-concentration and determination of hexavalent chromium in water samples. The hexavalent chromium was pre-concentrated using the HF-LPME technique via ion exchange or a coupled transport process through a supported ionic liquid (Aliquat 336) prior to colorimetric detection with diphenylcarbazide on the µPAD. The violet colour could be seen by the naked eye. Images from the µPADs were scanned using a commercial desktop scanner at 600 dpi resolution. ImageJ software was used for quantitative analysis by measuring the intensity values at green colour channel since it gave the best sensitivity among the RGB colour. Under optimal conditions, the calibration curve was linear in the range 10–90 µg L-1, with a limit of detection of 3 µg L-1. The developed method was successfully applied to determine the level of hexavalent chromium spiked into natural water samples at the parts-per-billion (ppb) level, and the results were in good agreement with those obtained using inductively coupled plasma atomic emission spectroscopy (ICP-AES). The developed method was able to improve the detection limit of the conventional µPAD, and was expected to be used for the effective analysis of hexavalent chromium in natural water.

KW - Colorimetric detection

KW - Hexavalent chromium

KW - Hollow fiber membrane liquid phase microextraction

KW - Microfluidic paper-based analytical devices

UR - http://www.scopus.com/inward/record.url?scp=85050468889&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85050468889&partnerID=8YFLogxK

U2 - 10.1016/j.talanta.2018.07.056

DO - 10.1016/j.talanta.2018.07.056

M3 - Article

AN - SCOPUS:85050468889

VL - 190

SP - 78

EP - 84

JO - Talanta

JF - Talanta

SN - 0039-9140

ER -