A bacterial biosensor for oxidative stress using the constitutively expressed redox-sensitive protein roGFP2

Carlos R. Arias-Barreiro, Keisuke Okazaki, Apostolos Koutsaftis, Salmaan H. Inayat-Hussain, Akiwo Tani, Maki Katsuhara, Kazuhide Kimbara, Izumi Mori

Research output: Contribution to journalArticle

17 Citations (Scopus)

Abstract

A highly specific, high throughput-amenable bacterial biosensor for chemically induced cellular oxidation was developed using constitutively expressed redox-sensitive green fluorescent protein roGFP2 in E. coli (E. coli-roGFP2). Disulfide formation between two key cysteine residues of roGFP2 was assessed using a double-wavelength ratiometric approach. This study demonstrates that only a few minutes were required to detect oxidation using E. coli-roGFP2, in contrast to conventional bacterial oxidative stress sensors. Cellular oxidation induced by hydrogen peroxide, menadione, sodium selenite, zinc pyrithione, triphenyltin and naphthalene became detectable after 10 seconds and reached the maxima between 80 to 210 seconds, contrary to Cd2+, Cu2+, Pb2+, Zn2+ and sodium arsenite, which induced the oxidation maximum immediately. The lowest observable effect concentrations (in ppm) were determined as 1.0 × 10-7 (arsenite), 1.0 × 10-4 (naphthalene), 1.0 × 10-4 (Cu2+), 3.8 × 10-4 (H2O2), 1.0 × 10-3 (Cd2+), 1.0 × 10-3 (Zn2+), 1.0 × 10-2 (menadione), 1.0 (triphenyltin), 1.56 (zinc pyrithione), 3.1 (selenite) and 6.3 (Pb2+), respectively. Heavy metal-induced oxidation showed unclear response patterns, whereas concentration-dependent sigmoid curves were observed for other compounds. In vivo GSH content and in vitro roGFP2 oxidation assays together with E. coli-roGFP2 results suggest that roGFP2 is sensitive to redox potential change and thiol modification induced by environmental stressors. Based on redox-sensitive technology, E. coli-roGFP2 provides a fast comprehensive detection system for toxicants that induce cellular oxidation.

Original languageEnglish
Pages (from-to)6290-6306
Number of pages17
JournalSensors
Volume10
Issue number7
DOIs
Publication statusPublished - Jul 2010

Fingerprint

Oxidative stress
Biosensing Techniques
bioinstrumentation
Biosensors
Oxidation-Reduction
Oxidative Stress
Escherichia coli
proteins
Proteins
Oxidation
oxidation
Vitamin K 3
Naphthalene
naphthalene
Sodium Selenite
Selenious Acid
Zinc
zinc
Sigmoid Colon
Sodium

Keywords

  • Environmental stressors
  • Oxidative biosensor
  • Ratiometric measurement
  • Redox- sensitive GFP
  • ROS

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Atomic and Molecular Physics, and Optics
  • Analytical Chemistry
  • Biochemistry

Cite this

A bacterial biosensor for oxidative stress using the constitutively expressed redox-sensitive protein roGFP2. / Arias-Barreiro, Carlos R.; Okazaki, Keisuke; Koutsaftis, Apostolos; Inayat-Hussain, Salmaan H.; Tani, Akiwo; Katsuhara, Maki; Kimbara, Kazuhide; Mori, Izumi.

In: Sensors, Vol. 10, No. 7, 07.2010, p. 6290-6306.

Research output: Contribution to journalArticle

Arias-Barreiro, Carlos R. ; Okazaki, Keisuke ; Koutsaftis, Apostolos ; Inayat-Hussain, Salmaan H. ; Tani, Akiwo ; Katsuhara, Maki ; Kimbara, Kazuhide ; Mori, Izumi. / A bacterial biosensor for oxidative stress using the constitutively expressed redox-sensitive protein roGFP2. In: Sensors. 2010 ; Vol. 10, No. 7. pp. 6290-6306.
@article{a07e43d7517b443aa206ba40cfd62bf0,
title = "A bacterial biosensor for oxidative stress using the constitutively expressed redox-sensitive protein roGFP2",
abstract = "A highly specific, high throughput-amenable bacterial biosensor for chemically induced cellular oxidation was developed using constitutively expressed redox-sensitive green fluorescent protein roGFP2 in E. coli (E. coli-roGFP2). Disulfide formation between two key cysteine residues of roGFP2 was assessed using a double-wavelength ratiometric approach. This study demonstrates that only a few minutes were required to detect oxidation using E. coli-roGFP2, in contrast to conventional bacterial oxidative stress sensors. Cellular oxidation induced by hydrogen peroxide, menadione, sodium selenite, zinc pyrithione, triphenyltin and naphthalene became detectable after 10 seconds and reached the maxima between 80 to 210 seconds, contrary to Cd2+, Cu2+, Pb2+, Zn2+ and sodium arsenite, which induced the oxidation maximum immediately. The lowest observable effect concentrations (in ppm) were determined as 1.0 × 10-7 (arsenite), 1.0 × 10-4 (naphthalene), 1.0 × 10-4 (Cu2+), 3.8 × 10-4 (H2O2), 1.0 × 10-3 (Cd2+), 1.0 × 10-3 (Zn2+), 1.0 × 10-2 (menadione), 1.0 (triphenyltin), 1.56 (zinc pyrithione), 3.1 (selenite) and 6.3 (Pb2+), respectively. Heavy metal-induced oxidation showed unclear response patterns, whereas concentration-dependent sigmoid curves were observed for other compounds. In vivo GSH content and in vitro roGFP2 oxidation assays together with E. coli-roGFP2 results suggest that roGFP2 is sensitive to redox potential change and thiol modification induced by environmental stressors. Based on redox-sensitive technology, E. coli-roGFP2 provides a fast comprehensive detection system for toxicants that induce cellular oxidation.",
keywords = "Environmental stressors, Oxidative biosensor, Ratiometric measurement, Redox- sensitive GFP, ROS",
author = "Arias-Barreiro, {Carlos R.} and Keisuke Okazaki and Apostolos Koutsaftis and Inayat-Hussain, {Salmaan H.} and Akiwo Tani and Maki Katsuhara and Kazuhide Kimbara and Izumi Mori",
year = "2010",
month = "7",
doi = "10.3390/s100706290",
language = "English",
volume = "10",
pages = "6290--6306",
journal = "Sensors",
issn = "1424-3210",
publisher = "Multidisciplinary Digital Publishing Institute (MDPI)",
number = "7",

}

TY - JOUR

T1 - A bacterial biosensor for oxidative stress using the constitutively expressed redox-sensitive protein roGFP2

AU - Arias-Barreiro, Carlos R.

AU - Okazaki, Keisuke

AU - Koutsaftis, Apostolos

AU - Inayat-Hussain, Salmaan H.

AU - Tani, Akiwo

AU - Katsuhara, Maki

AU - Kimbara, Kazuhide

AU - Mori, Izumi

PY - 2010/7

Y1 - 2010/7

N2 - A highly specific, high throughput-amenable bacterial biosensor for chemically induced cellular oxidation was developed using constitutively expressed redox-sensitive green fluorescent protein roGFP2 in E. coli (E. coli-roGFP2). Disulfide formation between two key cysteine residues of roGFP2 was assessed using a double-wavelength ratiometric approach. This study demonstrates that only a few minutes were required to detect oxidation using E. coli-roGFP2, in contrast to conventional bacterial oxidative stress sensors. Cellular oxidation induced by hydrogen peroxide, menadione, sodium selenite, zinc pyrithione, triphenyltin and naphthalene became detectable after 10 seconds and reached the maxima between 80 to 210 seconds, contrary to Cd2+, Cu2+, Pb2+, Zn2+ and sodium arsenite, which induced the oxidation maximum immediately. The lowest observable effect concentrations (in ppm) were determined as 1.0 × 10-7 (arsenite), 1.0 × 10-4 (naphthalene), 1.0 × 10-4 (Cu2+), 3.8 × 10-4 (H2O2), 1.0 × 10-3 (Cd2+), 1.0 × 10-3 (Zn2+), 1.0 × 10-2 (menadione), 1.0 (triphenyltin), 1.56 (zinc pyrithione), 3.1 (selenite) and 6.3 (Pb2+), respectively. Heavy metal-induced oxidation showed unclear response patterns, whereas concentration-dependent sigmoid curves were observed for other compounds. In vivo GSH content and in vitro roGFP2 oxidation assays together with E. coli-roGFP2 results suggest that roGFP2 is sensitive to redox potential change and thiol modification induced by environmental stressors. Based on redox-sensitive technology, E. coli-roGFP2 provides a fast comprehensive detection system for toxicants that induce cellular oxidation.

AB - A highly specific, high throughput-amenable bacterial biosensor for chemically induced cellular oxidation was developed using constitutively expressed redox-sensitive green fluorescent protein roGFP2 in E. coli (E. coli-roGFP2). Disulfide formation between two key cysteine residues of roGFP2 was assessed using a double-wavelength ratiometric approach. This study demonstrates that only a few minutes were required to detect oxidation using E. coli-roGFP2, in contrast to conventional bacterial oxidative stress sensors. Cellular oxidation induced by hydrogen peroxide, menadione, sodium selenite, zinc pyrithione, triphenyltin and naphthalene became detectable after 10 seconds and reached the maxima between 80 to 210 seconds, contrary to Cd2+, Cu2+, Pb2+, Zn2+ and sodium arsenite, which induced the oxidation maximum immediately. The lowest observable effect concentrations (in ppm) were determined as 1.0 × 10-7 (arsenite), 1.0 × 10-4 (naphthalene), 1.0 × 10-4 (Cu2+), 3.8 × 10-4 (H2O2), 1.0 × 10-3 (Cd2+), 1.0 × 10-3 (Zn2+), 1.0 × 10-2 (menadione), 1.0 (triphenyltin), 1.56 (zinc pyrithione), 3.1 (selenite) and 6.3 (Pb2+), respectively. Heavy metal-induced oxidation showed unclear response patterns, whereas concentration-dependent sigmoid curves were observed for other compounds. In vivo GSH content and in vitro roGFP2 oxidation assays together with E. coli-roGFP2 results suggest that roGFP2 is sensitive to redox potential change and thiol modification induced by environmental stressors. Based on redox-sensitive technology, E. coli-roGFP2 provides a fast comprehensive detection system for toxicants that induce cellular oxidation.

KW - Environmental stressors

KW - Oxidative biosensor

KW - Ratiometric measurement

KW - Redox- sensitive GFP

KW - ROS

UR - http://www.scopus.com/inward/record.url?scp=77957103528&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77957103528&partnerID=8YFLogxK

U2 - 10.3390/s100706290

DO - 10.3390/s100706290

M3 - Article

VL - 10

SP - 6290

EP - 6306

JO - Sensors

JF - Sensors

SN - 1424-3210

IS - 7

ER -