59Co NMR at pulsed high magnetic fields

Guo-Qing Zheng, K. Katayama, M. Kandatsu, N. Nishihagi, S. Kimura, M. Hagiwara, K. Kindo

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

We report the 59Co-NMR observation by spin-echo method at pulsed high magnetic fields up to 48 T. The 22 mm bore-resistive coil magnet with an inductance of 7.59 mH has a total time duration of 50 ms. After discharging the capacitor bank, NMR signals were observed near the maximum field. By repeatedly pulsing the RF sequence around the maximum field, spin echoes at different fields were recorded to give the NMR spectrum.

Original languageEnglish
Pages (from-to)280-283
Number of pages4
JournalJournal of Low Temperature Physics
Volume159
Issue number1-2
DOIs
Publication statusPublished - Apr 2010

Fingerprint

Nuclear magnetic resonance
Magnetic fields
nuclear magnetic resonance
echoes
magnetic fields
magnet coils
inductance
Inductance
Magnets
capacitors
Capacitors
cavities

Keywords

  • NMR
  • Pulsed magnetic field

ASJC Scopus subject areas

  • Condensed Matter Physics
  • Atomic and Molecular Physics, and Optics
  • Materials Science(all)

Cite this

Zheng, G-Q., Katayama, K., Kandatsu, M., Nishihagi, N., Kimura, S., Hagiwara, M., & Kindo, K. (2010). 59Co NMR at pulsed high magnetic fields. Journal of Low Temperature Physics, 159(1-2), 280-283. https://doi.org/10.1007/s10909-009-0130-6

59Co NMR at pulsed high magnetic fields. / Zheng, Guo-Qing; Katayama, K.; Kandatsu, M.; Nishihagi, N.; Kimura, S.; Hagiwara, M.; Kindo, K.

In: Journal of Low Temperature Physics, Vol. 159, No. 1-2, 04.2010, p. 280-283.

Research output: Contribution to journalArticle

Zheng, G-Q, Katayama, K, Kandatsu, M, Nishihagi, N, Kimura, S, Hagiwara, M & Kindo, K 2010, ' 59Co NMR at pulsed high magnetic fields', Journal of Low Temperature Physics, vol. 159, no. 1-2, pp. 280-283. https://doi.org/10.1007/s10909-009-0130-6
Zheng G-Q, Katayama K, Kandatsu M, Nishihagi N, Kimura S, Hagiwara M et al. 59Co NMR at pulsed high magnetic fields. Journal of Low Temperature Physics. 2010 Apr;159(1-2):280-283. https://doi.org/10.1007/s10909-009-0130-6
Zheng, Guo-Qing ; Katayama, K. ; Kandatsu, M. ; Nishihagi, N. ; Kimura, S. ; Hagiwara, M. ; Kindo, K. / 59Co NMR at pulsed high magnetic fields. In: Journal of Low Temperature Physics. 2010 ; Vol. 159, No. 1-2. pp. 280-283.
@article{a7ee1c9bd9c24bcba2ba654a4e984b5c,
title = "59Co NMR at pulsed high magnetic fields",
abstract = "We report the 59Co-NMR observation by spin-echo method at pulsed high magnetic fields up to 48 T. The 22 mm bore-resistive coil magnet with an inductance of 7.59 mH has a total time duration of 50 ms. After discharging the capacitor bank, NMR signals were observed near the maximum field. By repeatedly pulsing the RF sequence around the maximum field, spin echoes at different fields were recorded to give the NMR spectrum.",
keywords = "NMR, Pulsed magnetic field",
author = "Guo-Qing Zheng and K. Katayama and M. Kandatsu and N. Nishihagi and S. Kimura and M. Hagiwara and K. Kindo",
year = "2010",
month = "4",
doi = "10.1007/s10909-009-0130-6",
language = "English",
volume = "159",
pages = "280--283",
journal = "Journal of Low Temperature Physics",
issn = "0022-2291",
publisher = "Springer New York",
number = "1-2",

}

TY - JOUR

T1 - 59Co NMR at pulsed high magnetic fields

AU - Zheng, Guo-Qing

AU - Katayama, K.

AU - Kandatsu, M.

AU - Nishihagi, N.

AU - Kimura, S.

AU - Hagiwara, M.

AU - Kindo, K.

PY - 2010/4

Y1 - 2010/4

N2 - We report the 59Co-NMR observation by spin-echo method at pulsed high magnetic fields up to 48 T. The 22 mm bore-resistive coil magnet with an inductance of 7.59 mH has a total time duration of 50 ms. After discharging the capacitor bank, NMR signals were observed near the maximum field. By repeatedly pulsing the RF sequence around the maximum field, spin echoes at different fields were recorded to give the NMR spectrum.

AB - We report the 59Co-NMR observation by spin-echo method at pulsed high magnetic fields up to 48 T. The 22 mm bore-resistive coil magnet with an inductance of 7.59 mH has a total time duration of 50 ms. After discharging the capacitor bank, NMR signals were observed near the maximum field. By repeatedly pulsing the RF sequence around the maximum field, spin echoes at different fields were recorded to give the NMR spectrum.

KW - NMR

KW - Pulsed magnetic field

UR - http://www.scopus.com/inward/record.url?scp=77950367549&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77950367549&partnerID=8YFLogxK

U2 - 10.1007/s10909-009-0130-6

DO - 10.1007/s10909-009-0130-6

M3 - Article

AN - SCOPUS:77950367549

VL - 159

SP - 280

EP - 283

JO - Journal of Low Temperature Physics

JF - Journal of Low Temperature Physics

SN - 0022-2291

IS - 1-2

ER -